Welcome to our new website, found an issue or bug? Please report it here

RH62
Stick Type Rugged Hygrometer & Transducer
Models In Stock
- One Hand Operation
- Meter with Backlit LCD Display
- Max/Data Hold
- Analog Output Standard 10 mV/1° & 1%RH

Product Overview
- Battery Indication A low battery indication is displayed when the battery voltage drops below the operating level
- Battery life 200 hr
- Display Type LCD
- Display Type Note 3½ digit liquid crystal display (LCD) with maximum reading of 1999.
- Humidity Sensor Electronic capacitance polymer film
- Hysteresis ± 1%RH
- Length 40 mm
- Measurement Type Relative Humidity, Temperature
- Measuring Temperature Range, Max 100 °C
- Measuring Temperature Range, Min -20 °C
- Operating Temperature Note 0°C to 50°C at <75% relative humidity
- Relative Humidity Accuracy ± 2.5% RH
- Relative Humidity Accuracy Note ± 2.5%RH (10% to 90%RH) ± 5%RH ( 90%RH)
- Relative Humidity Resolution 0.1%RH
- Response Time 60 sec
- Sampling Rate 2.5 Hz (2.5 updates/second)
- Sensor Temperature Dependence Negligible between 0°C to 50°C
- Stability ± 2%RH
- Storage Temperature, Max 60 °C
- Storage Temperature, Min -20 °C
- Storage Temperature Note -20°C to 60°C at <80% relative humidity.
- Supply Voltage 6 Vdc
- Temperature Accuracy ± 0.5 °C
- Temperature Accuracy Note ± 0.5°C 0°C to 50°C ± 1°C -20°C to 0°C, 50°C to 100°C
- Temperature Coefficient 0.1 times the applicable accuracy specification per °C from °C to 18°C and 28°C to 50°C
- Temperature Resolution 0.1 °C
- Temperature Sensor Type RTD
- Temperature Sensor Type Note RTD Pt385/1000 Ohm
- Weight 160 g
- Weight Note 160g (including probe and batteries)
- Width 44 mm
Description
RH62C-MV & RH62F-MV Transducer (no display) Detection elements: Capacitive sensor and Pt385/1000 Ohm RTD sensor, Analog output: 10mV/1° & 1%RH, RH Range: 0.0 to 100.0% over 0 to 50°C , RH Basic accuracy: ± 2.5%, Connects to any DMM for display via STICK-CABLE ordered separately.RH62C & RH62F Hygrometer Detection elements: Capacitive sensor & Pt385/1000 Ohm RTD sensor, RH Range: 0.0 to 100.0% over 0 to 50°C, Basic accuracy: ± 2.5%, Backlit LCD Display
Show Ratings & Reviews