Product Specs
<< See all Product ModelsBrand |
![]() |
Additional Features 1 | Read and Source Signals |
Alerts | Red LED displays OVERLOAD or out of range conditions |
Battery life | 50 hr, low battery warning with less than 1 hr operation left |
Cold Junction Sensor | ≤± 0.01% °/ ° from ambient temperature ( °C or °F) |
Display Type | LCD |
Display Type Note | High contrast graphic Liquid Crystal Display. LED backlighting for use in low lit areas. |
Height | 41 mm |
Length | 143 mm |
Operating Temperature, Max | 60 °C |
Operating Temperature, Min | -20 °C |
Over-Voltage Protection | Up to 60 vrms (rated for 30 seconds), protection against misconnection |
RTD and OHMS Read | Resistance Ranges: 400Ω Range: 0.00 to 401.00 and 0.000 to 401.000 4000Ω Range: 0.0 to 4010.0 and 0.00 to 4010.00 Accuracy: ± (0.015% of reading + 0.05Ω) Excitation Current: 0.9 mA to 401Ω, 0.4 mA to 4010Ω (nominal) |
RTD and OHMS Source | 3- and 4-Wire Accuracy: From 1 to 10.2 mA External Excitation Current: ± (0.015% of setting + 0.05Ω) Below 1 mA of External Excitation Current: Add (0.025 mV/mA excitation current) 2-Wire Accuracy: Add 0.1Ω to 3-wire and 4-wire accuracy Resistance Ranges: 400Ω Range: 0.00 to 401.00 and 0.000 to 401.000 4000Ω Range: 0.0 to 4010.0 and 0.00 to 4010.00 RMS Noise: 400Ω Range: ≤± 0.005Ω from 0.1 to 10 Hz 4000Ω Range: ≤± 0.05Ω from 0.1 to 10 Hz Allowable Excitation Current Range: 400Ω Range: 10.2 mA max; steady or pulsed/intermittent 4000Ω Range: 1 mA max; steady or pulsed/intermittent Pulsed Excitation Current Compatibility: DC to 0.01 second pulse width, 0.025 mV, mA excitation current |
Relative Humidity Note | 10% ≤RH ≤90% (0 to 35°C),non-condensing; 10% ≤RH ≤70% (35 to 60°C),non-condensing |
Relative Humidity, Max | 0.9 |
Relative Humidity, Min | 10% |
Storage Temperature, Max | 60 °C |
Storage Temperature, Min | -30 °C |
Supply Voltage | 6 Vdc |
Temperature Effect | ≤± 25 ppm/°C |
Thermocouple Type | J, K, T, E, R, S, B, C, N, L, G, U, D |
Voltage Read | Ranges and Resolution: -13.000 to 80.000 mV and -13.0000 to 80.0000 mV Accuracy: ± (0.008% of reading + 0.006 mV) Input resistance: ≥10 MΩ Normal Mode Rejection: 50/60 Hz,50 dB Common Mode Rejection: 50/60 Hz,120 dB |
Voltage Source | Ranges and Resolution: -13.000 to 80.000 mV and -13.0000 to 80.0000 mV Accuracy: ± (0.008% of setting + 0.006 mV) Source Current: ≥10 mA Output Impedance: <0.3Ω RMS Noise: ≤± 0.0005 mV from 0.1 to 10 Hz Short Circuit Duration: Infinite |
Weight | 0.34 kg |
Weight Note | 0.34 kg (12.1 oz) with boot and batteries |
Width | 76 mm |
See All Specs |
Show Ratings & Reviews
Rated 4 out of
5
by
PROGNOST Systems Inc from
Works!
This device is a resource used by many within our company. It has worked properly when used. Our company monitors the large reciprocating compressors in different Plants around the US and Canada. We lost one we had previously so buying a new one shows it has been a great tool.
Date published: 2023-02-09
Rated 5 out of
5
by
MacGyver from
Themocouple calibrator
I bought this calibrator earlier this summer. It is easy to use. You easily go between the read and simulation functions. I use it a lot for troubleshooting temperature issues on various pieces of equipment.
Date published: 2018-11-07