Welcome to our new website, found an issue or bug? Please report it here

LC304
1 in Diameter, Miniature Button Compression Load Cell
Models In Stock
- Rugged Heavy Duty Design
- Built in Load Button for Easy Installation
- Miniature 1" (25 mm) Diameter and 1" (25 mm) High Case
- 5-Point Calibration with 59 kOhm Shunt Cal Data
LC304
From
C$
715.89
Models In Stock

Product Overview
- 5-Point Calibration 0%, 50%, 100%, 50%, 0%
- Accuracy ± 0.5 %
- Bridge Resistance 350 Ω
- Cable Length 5 ft
- Calibration Option 5 POINT NIST
- Electrical Connection Cable
- Electrical Output 2 mV/V
- Enclosure Ratings IP65
- Force Type Compression
- Full Scale Deflection 0.003 in
- Hysteresis ± 0.5%
- Linearity ± 0.5%
- Load Cell Type Button
- Materials Stainless Steel
- Operating Temperature, Max 107 °C
- Operating Temperature, Min -54 °C
- Overload, Max 300% FS
- Process Temperature, Max 71 °C
- Process Temperature, Min 16 °C
- Repeatability ± 0.5%
- Safe Overload 150% FS
- Supply Power Note 10 Vdc, 15 Vdc maximum
- Supply Voltage 10 Vdc
- Thermal Span Effect 0.036% FSO/°C
- Thermal Zero Effect 0.009% FSO/°C
- Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
- Zero/Balance Error ± 2%
OMEGA’s LC304 Series Load Cell offers the highest output of all miniature load cells. Its small 1" (25 mm) diameter makes it easy to mount in a pocket or on a flat surface. The rugged stainless steel case and high quality construction assure reliability in severe industrial environments.
The LC304 is also available in metric configurations, with ranges from 0-100 N to 0-50 kN. Please see the LCM304 for complete details, or contact our Pressure department for more information..
The LC304 is also available in metric configurations, with ranges from 0-100 N to 0-50 kN. Please see the LCM304 for complete details, or contact our Pressure department for more information..
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
omega load cells from
load cells 1000 lbs very accurat
they are great product 1000 lbs. very accurate
Date published: 2024-08-12
Rated 5 out of
5
by
PaulP from
Works great
Purchased to measure force in laboratory press. Works fine.
Date published: 2018-02-27
Is the output signal linear enough to use a multimeter to measure voltage and convert manually to load?
Hello, The output should be linear across the range. Initially you will have to measure the mV output at no load and full load to plot your slope. Once you have your slope you will be able to compute load vs mV outputs.
Date published: 2023-09-15
Hi.. What is the input impedance, output impedance and insulation resistance of LC 304-100 load cell?
Hello, Resistance will indicate much voltage is required to produce a current. Impedance generally extends the concept of resistance to changing voltages. In addition to telling you just how much current is produced; it also indicates how much the current lags behind the voltage. In short, it gives both amplitude and phase relationship between voltage and current. So I believe you are looking for the input and output resistance: in case of the LC304 nominal input and output bridge resistance will be 350 ohms. The insulation resistance is not listed, please email us your application at pressure@omega.com, we will review and advise if this product will be viable for your needs.
Date published: 2024-09-27
is this a full, half, or quarter bridge device?
This is a full bridge device
Date published: 2022-03-17
What is the sensitivity of this device?
Nominal sensitivity of the LC304 Series is 2mV/V which would give you a 0 to 20 mV output signal across the calibrated range of the load cell with the 10VDC excitation supplied.
Date published: 2023-02-07
Is this model compatible with NI and LabView?
This load cell is simply a strain gage bridge device the produces a linear millvolt output over the load range of the cell. NI and Labview should have devices the accept this type of signal. NI for sure has devices the will both power the load cell and read the signal output
Date published: 2021-10-07