LCM1001-LCM1011
Metric, Cannister Load Cell
Models In Stock
- 0.25% Interchangeable for Multiple Load Cell Applications
- 5-Point NIST Traceable Calibration with 59 kOhm Shunt Cal Data Provided
- Canister Design Ideal for Axial Compression Applications
- Heavy Duty Environmentally Sealed Case for Harsh Environments
LCM1001-LCM1011
From
C$
1,907.00
Models In Stock

Product Overview
- 5-Point Calibration 0%, 50%, 100%, 50%, 0% (in Compression)
- Base Plate LCM1000-BP4
- Cable Length 15 ft
- Calibration Option 5 POINT NIST
- Electrical Connection Cable
- Electrical Output 2 mV/V
- Enclosure Ratings IP67
- Force Type Compression
- Full Scale Deflection 0.02 in
- Hysteresis ± 0.03%
- Input Resistance 350 ± 10 Ω
- Interchangeability 0.0025
- Linearity ± 0.05%
- Materials 17-4 PH Stainless Steel
- Operating Temperature, Max 100 °C
- Operating Temperature, Min -46 °C
- Outer Diameter 89 mm
- Output Resistance 350 ± 10 Ω
- Overload, Max 300% FS
- Process Temperature, Max 71 °C
- Process Temperature, Min 16 °C
- Repeatability ± 0.02%
- Safe Overload 150% FS
- Supply Power Note 10 Vdc, 15 Vdc maximum
- Supply Voltage 10 Vdc
- Thermal Span Effect ± 0.0018% rdg/°C
- Thermal Zero Effect ± 0.0018% FS/°C
- Top Plate LCM1000-TP4
- Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input; Yellow: Shield
- Zero/Balance Error ± 1%
The LCM1001 & LCM1011 are also available in standard configurations, with 0-500 to 0-2,000,000 lb ranges. Please see the LC1001 for complete details, or contact our Pressure department for more information.
SPECIFICATIONS
Excitation: 10 Vdc (15 Vdc max)
Output: 2 mV/V ± 0.25%
5-Point Calibration (in Compression): 0%, 50%, 100%, 50%, 0% calibrated to full scale up to 300,000 lb; load cells over 300,000 lb calibrated at 300,000 lb. For a full scale calibration over 300,000 lb, specify option "-FS" after model number (consult Sales for price and delivery)
Protection Class: IP67
Linearity: ± 0.05% FSO
Hysteresis: ± 0.03% FSO
Repeatability: ± 0.02% FSO
Zero Balance: ± 1% FS
Operating Temp Range: -46 to 100°C (-50 to 212°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ± 0.0018% FS/°C
Span: ± 0.0018% rdg/°C
Safe Overload: 150% of rated capacity
Ultimate Overload: 300% of rated capacity
Input Resistance: 350 ± 10 ?
Output Resistance: 350 ± 10 ?
FS Deflection: 0.18 to 0.50 mm (0.007 to 0.020") typical
Construction:17-4 PH stainless steel
Electrical:
LC1001/LCM1001: 4.8 m (15') 4-conductor shielded PVC cable
LC1011/LCM1011: PTIH-10-6P (or equiv.)
Mating Connector: PT06F10-6S, sold separately
SPECIFICATIONS
Excitation: 10 Vdc (15 Vdc max)
Output: 2 mV/V ± 0.25%
5-Point Calibration (in Compression): 0%, 50%, 100%, 50%, 0% calibrated to full scale up to 300,000 lb; load cells over 300,000 lb calibrated at 300,000 lb. For a full scale calibration over 300,000 lb, specify option "-FS" after model number (consult Sales for price and delivery)
Protection Class: IP67
Linearity: ± 0.05% FSO
Hysteresis: ± 0.03% FSO
Repeatability: ± 0.02% FSO
Zero Balance: ± 1% FS
Operating Temp Range: -46 to 100°C (-50 to 212°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ± 0.0018% FS/°C
Span: ± 0.0018% rdg/°C
Safe Overload: 150% of rated capacity
Ultimate Overload: 300% of rated capacity
Input Resistance: 350 ± 10 ?
Output Resistance: 350 ± 10 ?
FS Deflection: 0.18 to 0.50 mm (0.007 to 0.020") typical
Construction:17-4 PH stainless steel
Electrical:
LC1001/LCM1001: 4.8 m (15') 4-conductor shielded PVC cable
LC1011/LCM1011: PTIH-10-6P (or equiv.)
Mating Connector: PT06F10-6S, sold separately