Product Overview
- Accuracy Detail pH: ±0.01 pH,ORP/ISE:±0.1 mV,Temperature Calibrated Accuracy: ±0.15°C ,@ 25°C ambient (±0.015 Ω); pH EMI Susceptibility: <0.2 pH @ 3V/M, 80 MHz to 1 GHz; ORP/ISE Susceptibility: <10 mV @ 3V/M, 80 MHz to 1 GHz
- Battery life 1 yr, typical with reading interval of 1 min
- Battery Size and Type Alkaline 9V
- Baud Rate 115200
- Calibration Digital calibration through software
- Data Interface USB
- Display Note LCD Dimensions: 1.375" x 2.5" Backlight: Configurable w/auto shut-off and contrast adjustment
- Display Type LCD
- Electrical Connection Note Temperature: Removable screw terminal, pH: Female BNC
- Height 1.25 in
- Impedance Input 1012 Ω
- Indicator Type Power, Status, Memory
- Length 3.3 in
- Materials Aluminum
- Measurement Type Temperature, pH/ORP/ISE
- Memory 131,071 readings
- Memory Note 131,071 readings per channel
- Number of Measurements 2
- Operating Temperature, Max 50 °C
- Operating Temperature, Min -5 °C
- PH Measurement Range -2 to 16 pH
- Real Time Recording The device may be used with PC to monitor and record data in Real-time
- Relative Humidity 0 to 95% RH non-condensing
- Resolution Temperature: 0.01°C, Measurement: 0.01 pH
- Sampling Rate 2 Hz (2 updates/second)
- Sampling Rate Note 1 Reading every 2 Seconds to 1 Every 24 Hours
- Sensor Type pH, RTD
- Software XP SP3/Vista/7 and 8
- Start Modes Delayed Start, Immediate Start
- Supply Power Type Battery
- Temperature Measurement Range -40 to 110 °C
- Time Accuracy ±1 minute/month (at 25°C; RS232 cable not in use)
- USB Cable Length 6 ft
- Weight 440 g
- Width 4.8 in
- Wire Code Option 2 -, 3 - , 4- Wire
The OM-CP-PHTEMP2000 is a battery powered, stand alone pH and temperature data logger with an LCD. The OM-CP-PHTEMP2000 will directly connect to many commonly used pH, ORP and ISE electrodes through a female BNC connector mounted on its side. Temperature compensation is done automatically by connecting an RTD to the unit.
The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. The OM-CP-PHTEMP2000 makes data retrieval quick and easy. Simply plug it into an empty com port and our user-friendly software does the rest.
SPECIFICATIONS
TEMPERATURE
Input: 100Ω Pt RTD
Measurement Range: -40 to 110 °C (-72 to 230 °F, 80 to 145 Ω)
Resolution: 0.01 °C (0.001 Ω)
Calibrated Accuracy: ±0.15 °C @ 25 °C ambient ( ±0.015 Ω)
Input Connection: Removable screw terminal; 2-, 3- or 4-wire interface
PH/ORP/ISE
Input Connection: Female BNC
Measurement Range: -2.00 to 16.00 pH
Resolution: 0.01 pH (0.001 pH)
pH Accuracy: ±0.01 pH
pH EMI Susceptibility: <0.2 pH @ 3V/M, 80 MHz to 1 GHz
ORP/ISE Accuracy: ±0.1 mV
ORP/ISE Susceptibility: <10 mV @ 3V/M, 80 MHz to 1 GHz
Input Impedance: 1012 Ω typical
Start Modes: Software programmable immediate start or delay start up to six months in advance
Real-Time Recording: May be used with PC to monitor and record data in real time
DOT-MATRIX LCD
Dimensions: 35 H x 63 mm W (1.375 x 2.5')
Text: Configurable channel text size
Indicators: Power, status, memory
Backlight: Configurable w/auto shut-off and contrast adjustment
Memory: 131,071 readings per channel
Reading Rate: 1 reading every 2 seconds to 1 every 24 hours
Calibration: Digital calibration through software
Battery Type: 9V lithium or alkaline battery (included); user replaceable
Battery Life: 1 year battery life at 1 minute reading rate with display off;
30 days typical with continuous display use; optional AC adaptor available
Data Format: Date and time stamped °C, °F, K, R, Ω pH, V, mV,
engineering units specified through software
Time Accuracy: ±1 minute/month (at 25 °C; RS-232 cable not in use)
Computer Interface: PC serial or USB (interface cable required); 115,200 baud
Software: XP SP3/Vista/7 and 8 (32-bit and 64-bit)
Operating Environment: -5 to 50 °C (23 to 122 °F), 0 to 95% RH (non-condensing)
Dimensions: 84 H x 122 W x 32 mm D (3.3 x 4.8 x 1.25')
Weight: 440 g (16 oz)
Read More
The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. The OM-CP-PHTEMP2000 makes data retrieval quick and easy. Simply plug it into an empty com port and our user-friendly software does the rest.
SPECIFICATIONS
TEMPERATURE
Input: 100Ω Pt RTD
Measurement Range: -40 to 110 °C (-72 to 230 °F, 80 to 145 Ω)
Resolution: 0.01 °C (0.001 Ω)
Calibrated Accuracy: ±0.15 °C @ 25 °C ambient ( ±0.015 Ω)
Input Connection: Removable screw terminal; 2-, 3- or 4-wire interface
PH/ORP/ISE
Input Connection: Female BNC
Measurement Range: -2.00 to 16.00 pH
Resolution: 0.01 pH (0.001 pH)
pH Accuracy: ±0.01 pH
pH EMI Susceptibility: <0.2 pH @ 3V/M, 80 MHz to 1 GHz
ORP/ISE Accuracy: ±0.1 mV
ORP/ISE Susceptibility: <10 mV @ 3V/M, 80 MHz to 1 GHz
Input Impedance: 1012 Ω typical
Start Modes: Software programmable immediate start or delay start up to six months in advance
Real-Time Recording: May be used with PC to monitor and record data in real time
DOT-MATRIX LCD
Dimensions: 35 H x 63 mm W (1.375 x 2.5')
Text: Configurable channel text size
Indicators: Power, status, memory
Backlight: Configurable w/auto shut-off and contrast adjustment
Memory: 131,071 readings per channel
Reading Rate: 1 reading every 2 seconds to 1 every 24 hours
Calibration: Digital calibration through software
Battery Type: 9V lithium or alkaline battery (included); user replaceable
Battery Life: 1 year battery life at 1 minute reading rate with display off;
30 days typical with continuous display use; optional AC adaptor available
Data Format: Date and time stamped °C, °F, K, R, Ω pH, V, mV,
engineering units specified through software
Time Accuracy: ±1 minute/month (at 25 °C; RS-232 cable not in use)
Computer Interface: PC serial or USB (interface cable required); 115,200 baud
Software: XP SP3/Vista/7 and 8 (32-bit and 64-bit)
Operating Environment: -5 to 50 °C (23 to 122 °F), 0 to 95% RH (non-condensing)
Dimensions: 84 H x 122 W x 32 mm D (3.3 x 4.8 x 1.25')
Weight: 440 g (16 oz)