FTB601B-T
All Plastic Flow Sensors for Low to Medium Flows

Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product ModelsBrand |
![]() |
Accuracy | ± 1 % |
Approvals | RoHS, CE |
Cable Length | 0.9 m |
Electrical Output | Square Wave Pulse |
K-Factor | 36000 pulses/gal |
Length | 3.8 in |
Materials, Wetted | PVDF |
Media Compatibility | Liquids |
Operating Pressure Note | 150 psig at 79°C (175°F) |
Operating Pressure, Max | 150 psi |
Pipe Size, Max | 0.27 in |
Process Connection Size | 1/4 in |
Process Connection Type | NPT Male |
Repeatability | ±0.1% |
Supply Current | 6 to 33 mA |
Supply Voltage | 8 to 24 Vdc |
Thread Length | 0.35 in |
Viscosity Range | 1 to 15 cSt |
Volumetric Flow Rate, Max | 2 l/min |
Volumetric Flow Rate, Min | 0.1 l/min |
See All Specs |
PDFs & Manuals
Show Ratings & Reviews
Rated 1 out of
5
by
Bruce from
Omega FTB600B Faulty Labelling Added Cost
I installed this unit according to the proper direction of flow indicated on the label. Along with the integration of the Omega DPF701 display, I spent many hours trying to get the assembly to indicate the proper flow rate. I finally realized that the direction-of-flow label may be affixed incorrectly. I checked the picture in the manual and, sure enough, the label was upside-down. I reversed the flow and the assembly functioned properly. For $600, I expect a better quality product that does not cost me valuable time to implement. Photo attached.
Date published: 2017-04-07
Rated 5 out of
5
by
erosion researcher from
Compact, easy to install and set up
This sensor is relatively small. After calling tech support for some assistance, it was easy to correctly connect it with the meter. The meter was simple and quick to configure, too.
Date published: 2016-03-09
Rated 5 out of
5
by
Kosanovic from
Good flowmeter for lower temperatures
The flowmeters are easy to setup and use. You need a pulse counter card, alternative is a pulse to voltage converter, for example IFMA0035.
Date published: 2022-02-24
Rated 1 out of
5
by
shoukasg from
Don't operate at the upper temperature limit.
I have burnt out 2 of these flowmeters in a non-corrosive, hot water application. These flow meters are accurate out of the box and have good turndown ratio but I am operating them just under their spec at 180F. The manufacturer claims 185F as the upper limit. I would expect a little wiggle room but I have gone through 2 devices already.
Date published: 2021-05-19