Scale is 2mv/V: when powered with a 12vdc supply, what would the scaling end points be? on a 0-10VDC input: full scale min = ? full scale max = ?
Asked by: Richard23
Richard, if you are powering the load cell with 10 volts DC, at no load you will see 0 mV out and at full load you will see 20 mV out (Nominal)
If you are powering the load cell with 12 volts, at no load you will see 0 mV and at full load you will see 24 mV. (Nominal)
Answered by: SAE DVJ