Welcome to our new website, found an issue or bug? Please report it here

MTS3-HEATER
Stainless Steel Immersion Heater 2.5 in NPT Process Water
- Stainless Steel Wetted Construction
- 120, 208, 240, 480V 1 and 3 Phase Power
- Reliable Heater Design
- General Purpose Enclosure, NEMA-1 Rated and UL Listed
MTS3-HEATER
From
C$
2 071.15

Product Overview
- Form factor Screw Plug Immersion
- Heated Medium Water
- Number of Heating Elements 3
- Process Connection Size 2 1/2 in
- Process Connection Type NPT Male
- Sheath Material Stainless Steel
Please Note: This immersion heater should be used with an approved temperature control device to assure safe operation. See Section P for our selection of process controllers.
/*Insert the suffix “3P” to the model number for 3 phase power.
1 Heaters with General Purpose Enclosures are UL Listed and CSA Certified except models with (exceeds 48 amps).
2 Heaters with Moisture Resistant/Explosion Resistant Enclosures are CSA NRTL/C certified and are not intended for use in hazardous areas. Except models with (exceeds 48 amps).
kW | Volts | W/in2 | No. Htg. Elem. | Dim. B in (cm) | E1 General Purpose Enclosure1 | E2 Moisture Res/Explos. Res.2 | ||
Model No. | Wt. Ib (kg) | Model No. | Wt. Ib (kg) | |||||
3 | 120 | 51 | 3 | 6 7/8 (17) | MTS-330A/120V | 5(2) | MTS-330E2/120V | 8 (4) |
3 | 208 | 51 | 3 | 6 7/8 (17) | MTS-330A/208V/* | 5(2) | MTS-330E2/208V/* | 8 (4) |
3 | 240 | 51 | 3 | 6 7/8 (17) | MTS-330A/240V/* | 5(2) | MTS-330E2/240V/* | 8 (4) |
3 | 480 | 51 | 3 | 6 7/8 (17) | MTS-330A/480V/* | 5(2) | MTS-330E2/480V/* | 8 (4) |
4.5 | 120 | 48 | 3 | 10 7/8 (28) | MTS-345A/120V | 6(3) | MTS-345E2/120V | 9 (4) |
4.5 | 208 | 48 | 3 | 10 7/8 (28) | MTS-345A/208V/* | 6(3) | MTS-345E2/208V/* | 9 (4) |
4.5 | 240 | 48 | 3 | 10 7/8 (28) | MTS-345A/240V/* | 6(3) | MTS-345E2/240V/* | 9 (4) |
4.5 | 480 | 48 | 3 | 10 7/8 (28) | MTS-345A/480V/* | 6(3) | MTS-345E2/480V/* | 9 (4) |
6 | 120 | 48 | 3 | 16 7/8 (43) | MTS-360A/120V | 6(3) | MTS-360E2/120V | 9 (4) |
6 | 208 | 48 | 3 | 16 7/8 (43) | MTS-360A/208V/* | 6(3) | MTS-360E2/208V/* | 9 (4) |
6 | 240 | 48 | 3 | 16 7/8 (43) | MTS-360A/240V/* | 6(3) | MTS-360E2/240V/* | 9 (4) |
6 | 480 | 48 | 3 | 16 7/8 (43) | MTS-360A/480V/* | 6(3) | MTS-360E2/480V/* | 9 (4) |
7.5 | 208 | 53 | 3 | 18 11/16 (49) | MTS-375A/208V/* | 6(3) | MTS-375E2/208V/* | 9 (4) |
7.5 | 240 | 53 | 3 | 18 11/16 (62) | MTS-375A/240V/* | 6(3) | MTS-375E2/240V/* | 9 (4) |
7.5 | 480 | 53 | 3 | 18 11/16 (62) | MTS-375A/480V/* | 6(3) | MTS-375E2/480V/* | 9 (4) |
9 | 208 | 47 | 3 | 24 (61) | MTS-390A/208V/* | 7(3) | MTS-390E2/208V/* | 10 (5) |
9 | 240 | 47 | 3 | 24 (61) | MTS-390A/240V/* | 7(3) | MTS-390E2/240V/* | 10 (5) |
9 | 480 | 47 | 3 | 24 (61) | MTS-390A/480V/* | 7(3) | MTS-390E2/480V/* | 10 (5) |
12 | 208 | 46 | 3 | 31 7/8 (81) | MTS-3120A/208V/* | 9 (4) | MTS-3120E2/208V/* | 12 (5) |
12 | 240 | 46 | 3 | 31 7/8 (81) | MTS-3120A/240V/* | 9 (4) | MTS-3120E2/240V/* | 12 (5) |
12 | 480 | 46 | 3 | 31 7/8 (81) | MTS-3120A/480V/* | 9 (4) | MTS-3120E2/480V/* | 12 (5) |
15 | 208 | 46 | 3 | 39 3/8 (101) | MTS-3150A/208V/* | 10 (5) | MTS-3150E2/208V/* | 13 (6) |
15 | 240 | 46 | 3 | 39 3/8 (101) | MTS-3150A/240V/* | 10 (5) | MTS-3150E2/240V/* | 13 (6) |
15 | 480 | 46 | 3 | 39 3/8 (101) | MTS-3150A/480V/* | 10 (5) | MTS-3150E2/480V/* | 13 (6) |
18 | 208 | 51 | 3 | 46 7/8 (118) | MTS-3180A/208V/* | 12 (5) | MTS-3180E2/208V/* | 15 (7) |
18 | 240 | 51 | 3 | 46 7/8 (118) | MTS-3180A/240V/* | 12 (5) | MTS-3180E2/240V/* | 15 (7) |
18 | 480 | 51 | 3 | 46 7/8 (118) | MTS-3180A/480V/* | 12 (5) | MTS-3180E2/480V/* | 15 (7) |
1 Heaters with General Purpose Enclosures are UL Listed and CSA Certified except models with (exceeds 48 amps).
2 Heaters with Moisture Resistant/Explosion Resistant Enclosures are CSA NRTL/C certified and are not intended for use in hazardous areas. Except models with (exceeds 48 amps).
PDFs & Manuals
Show Ratings & Reviews