TMO-HEATER-MEDIUM
Steel Flanged Immersion Heater Medium Weight Oil
- UL Listed
- 3 to 24 kW
- Low Watt Density, 15 W/in2
- 3.5 and 6 Inch 150 lb. steel Flange
TMO-HEATER-MEDIUM
From
C$
4,188.66

Product Overview
- Applications Oils
- Form factor Flanged Immersion
- Heated Medium Oil
- Power Density 15 W/in²
FEATURES
Heavy coil construction— Watt density on the heating coil is designed for low watt density operation by increasing the coil diameter and length to give maximum coil surface area and limit coil surface temperature, providing longer coil life.
CAUTION AND WARNING!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warning.

/* Add the suffix “/3P” to the catalog number for 3 phase power.
/** Designate voltage, i.e., 240 for 240 VAC or 480 for 480 VAC.
Note: Larger flange sizes and kW rating available. Contact Omegalux®
1 Heaters with General Purpose and Moisture Resistant Enclosures are UL Listed and CSA Certified. 2 Heaters with Explosion Resistant Enclosures are CSA NRTL/C certified and are not intended for use in hazardous areas.
When using the Part Number Builder some part number combinations may not be valid!
Please review the tables and spec sheet for valid part numbers, or consult with Temperature
Engineering if you need help selecting a heater or to verify part number validity or availability!
Heavy coil construction— Watt density on the heating coil is designed for low watt density operation by increasing the coil diameter and length to give maximum coil surface area and limit coil surface temperature, providing longer coil life.
CAUTION AND WARNING!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warning.

kW | Dim.B in (cm) | Wt. Ib(kg) | E1 General Purpose Enclosure1 Model No. | Dim. N. in(cm) | E2 Moisture Resistant/ Explosion Res.Encl.2 Model No. | Dim. N in(cm) |
3 Inch-150 Ibs. Steel Flange, 3 Steel Sheath Elements — 15 W/in2 | ||||||
3 | 25 3/16 (64) | 17(8) | TMO-30315/240/ | 1 (3) | TMO-30315E2/240/* | 3/4 (2) |
3 | 25 3/16 (64) | 17(8) | TMO-30315/480/ | 1 (3) | TMO-30315E2/480/* | 3/4 (2) |
4 | 33 1/16 (84) | 18 (8) | TMO-30415/240/ | 1 (3) | TMO-30415E2/240/* | 3/4 (2) |
4 | 33 1/16 (84) | 18 (8) | TMO-30415/480/ | 1 (3) | TMO-30415E2/480/* | 3/4 (2) |
6 | 48 1/16 (122) | 21 (10) | TMO-30615/240/ | 1(3) | TMO-30615E2/240/* | 3/4 (2) |
6 | 48 1/16 (122) | 21 (10) | TMO-30615/240/* | 1(3) | TMO-30615E2/240/* | 3/4 (2) |
kW | Circ. & Ph. | Dim.B in (cm) | Wt. Ib(kg) | General Purpose Enclosure1 Model No. | Dim. N. in(cm) | E3 Explosion Res. Encl.2 Model No. | Dim. N in(cm) | E4 Moisture Res.Encl.1 Model No. | Dim. N in(cm) |
5 Inch-150 Lb. Steel Flange, 6 Stainless Sheath Elements — 15 W/in2 | |||||||||
8 | 1-3 | 33 1/16 (84) | 33 (15) | TMO-60825/**/3P | 1 (3) | TMO-60825E3/**/3P | 1 1/2 (4) | TMO-60825E4/**/3P | 1 (3) |
10 | 1-3 | 40 9/16 (103) | 34 (15) | TMO-61025/**/3P | 1 (3) | TMO-61025E3/**/3P | 1 1/2 (4) | TMO-61025E4/**/3P | 1 (3) |
12 | 1-3 | 48 1/16(122) | 37 (17) | TMO-61225/**/3P | 1 (3) | TMO-61225E3/**/3P | 1 1/2 (4) | TMO-61225E4/**/3P | 1 (3) |
15 | 1-3 | 57 1/16 (145) | 40 (18) | TMO-61525/**/3P | 1 (3) | TMO-61525E3/**/3P | 1 1/2 (4) | TMO-61525E4/**/3P | 1 (3) |
18 | 1-3 | 68 1/16 (173) | 43 (20) | TMO-61825/**/3P | 1 (3) | TMO-61855E3/**/3P | 1 1/2 (4) | TMO-61825E4/**/3P | 1 (3) |
6 Inch-150 Lb. steel Flange, 12 Cooper Sheath Elements — 15 W/in2 | |||||||||
12 | 2-3 | 25 1/8 (64) | 67 (30) | TMO-1212F1/**/3P | 1 (3) | TMO-1212F1E3/**/3P | 1 1/2 (4) | TMO-1212F1E4/**/3P | 1 1/2 (4) |
16 | 2-3 | 33 (84) | 76 (34) | TMO-1216F1/**/3P | 1 (3) | TMO-1216F1E3/**/3P | 1 1/2 (4) | TMO-1216F1E4/**/3P | 1 1/2 (4) |
20 | 2-3 | 40 1/2 (103) | 84 (38) | TMO-1220F1/240/3P | 2 (5) | TMO-1220F1E3/240/3P | 1 1/2 (4) | TMO-1220F1E4/240/3P | 1 1/2 (4) |
20 | 2-3 | 40 1/2 (103) | 84 (38) | TMO-1220F1/480/3P | 1 (3) | TMO-1220F1E3/480/3P | 1 1/2 (4) | TMO-1220F1E4/480/3P | 1 1/2 (4) |
24 | 2-3 | 48 (122) | 111 (50) | TMO-1224F1/240/3P | 2 (5) | TMO-1224F1E3/240/3P | 1 1/2 (4) | TMO-1224F1E4/240/3P | 1 1/2 (4) |
24 | 2-3 | 48 (122) | 111 (50) | TMO-1224F1/480/3P | 1 (3) | TMO-1224F1E3/480/3P | 1 1/2 (4) | TMO-1224F1E4/480/3P | 1 1/2 (4) |
/** Designate voltage, i.e., 240 for 240 VAC or 480 for 480 VAC.
Note: Larger flange sizes and kW rating available. Contact Omegalux®
1 Heaters with General Purpose and Moisture Resistant Enclosures are UL Listed and CSA Certified. 2 Heaters with Explosion Resistant Enclosures are CSA NRTL/C certified and are not intended for use in hazardous areas.
When using the Part Number Builder some part number combinations may not be valid!
Please review the tables and spec sheet for valid part numbers, or consult with Temperature
Engineering if you need help selecting a heater or to verify part number validity or availability!