Welcome to our new website, found an issue or bug? Please report it here

TLO-KTLO-SERIES
Steel L-Shaped Immersion Heater Over the Side
Models In Stock
- 2 to 10 kW
- 120, 240, 480 V, 1 & 3 Phase
- Heavy Duty Steel Heating Elements, Riser and Junction Box
- Optional Thermostat Kits are Available to Fit into Terminal Box
TLO-KTLO-SERIES
From
C$
2 958.89
Models In Stock

Product Overview
- Additional Features Curved Elements
- Form factor Over the Side Immersion
- Heated Medium Oil
- Power Density 20 W/in²
- Sheath Material Steel
FEATURES
Tubular heating elements are brazed into a junction box. All wetted parts of TLO & KTLO Series heaters are steel. Sludge legs (to keep heated portion of the unit off the bottom of the tank) are standard.
APPLICATIONS
Medium weight oils, alkali, soaking cleaners, degreasing solutions, caustics, solvent type oils, heat transfer fluids.
CAUTION AND WARNING!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warnings.

* Designate voltage, i.e. insert 240 for 240 V or 480 for 480 V.
** Add the suffix “3P” to the model number for 3 phase power.
Optional thermostat kits are available to fit into heater terminal box.
Tubular heating elements are brazed into a junction box. All wetted parts of TLO & KTLO Series heaters are steel. Sludge legs (to keep heated portion of the unit off the bottom of the tank) are standard.
APPLICATIONS
Medium weight oils, alkali, soaking cleaners, degreasing solutions, caustics, solvent type oils, heat transfer fluids.
CAUTION AND WARNING!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warnings.

kW | Riser (A) in (cm) | Straight Elements | Curved Elements | Wt. Lb (kg) | ||
Min. Tank Clearance (B)--in (cm) | Model No. | Min. Tank Clearance (B)--in (cm) | Model No. | |||
Two Elements — Steel, 20 W/in.2 | ||||||
2 | 36 (91) | 22 1/4 (57) | TLO-220A-036/120V | 13 3/4 (35) | KTLO-220A-036/120V | 9 (4) |
2 | 36 (91) | 22 1/4 (57) | TLO-220A-036/* | 13 3/4 (35) | KTLO-220A-036/* | 9 (4) |
3 | 36 (91) | 29 1/2 (75) | TLO-230A-036/120V | 16 1/8 (41) | KTLO-230A-036/120V | 10 (5) |
3 | 36 (91) | 29 1/24 (75) | TLO-230A-036/* | 16 1/8 (35) | KTLO-230A-036/* | 10 (5) |
5 | 48 (121) | 45 (103) | TLO-250A-048/120V | 21 1/4 (57) | KTLO-250A-048/120V | 10 (5) |
5 | 48 (121) | 45 (103) | TLO-250A-048/* | 21 1/4 (57) | KTLO-250A-048/* | 12 (5) |
6 | 48 (121) | 52 1/2 (133) | TLO-260A-048/* | 23 1/2 (59) | KTLO-260A-048/* | 13 (6) |
7 | 48 (121) | 56 1/2 (144) | TLO-260A-048/* | 24 7/8 (59) | KTLO-260A-048/* | 14 (7) |
Three Elements — Steel, 20 W/in2 | ||||||
3 | 36 (91) | 22 1/4 (57) | TLO-330A-036/120V | 13 3/4 (35) | KTLO-330A-036/120V | 12 (4) |
3 | 36 (91) | 22 1/4 (57) | TLO-330A-036/240V/** | 13 3/4 (35) | KTLO-330A-036/240V/** | 12 (4) |
3 | 36 (91) | 22 1/4 (57) | TLO-330A-036/480V/** | 13 3/4 (35) | KTLO-330A-036/480V/** | 12 (4) |
4.5 | 36 (91) | 29 1/2 (75) | TLO-345A-036/120V | 16 1/8 (41) | KTLO-345A-036/120V | 13 (6) |
4.5 | 36 (91) | 29 1/2 (75) | TLO-345A-036/240V/** | 16 1/8 (41) | KTLO-345A-036/240V/** | 13 (6) |
4.5 | 36 (91) | 29 1/2 (75) | TLO-345A-036/480V/** | 16 1/8 (41) | KTLO-345A-036/480V/** | 13 (6) |
6 | 48 (121) | 37 3/8 (95) | TLO-360A-048/120V | 18 5/8 (47) | KTLO-360A-048/120V | 13 (6) |
6 | 48 (121) | 37 3/8 (95) | TLO-360A-048/240V/** | 18 5/8 (47) | KTLO-360A-048/240V/** | 13 (6) |
6 | 48 (121) | 37 3/8 (95) | TLO-360A-048/480V/** | 18 5/8 (47) | KTLO-360A-048/480V/** | 13 (6) |
7.5 | 48 (121) | 45 (103) | TLO-375A-048/120V | 21 1/4 (54) | KTLO-375A-048/120V | 14 (6) |
7.5 | 48 (121) | 45 (103) | TLO-375A-048/240V/** | 21 1/4 (54) | KTLO-375A-048/240V/** | 14 (6) |
7.5 | 48 (121) | 45 (103) | TLO-375A-048/480V/** | 21 1/4 (54) | KTLO-375A-048/480V/** | 14 (6) |
9 | 48 (121) | 52 1/2 (133) | TLO-390A-048/240V/** | 23 1/2 (60) | KTLO-390A-048/240V/** | 15 (7) |
9 | 48 (121) | 52 1/2 (133) | TLO-390A-048/480V/** | 23 1/2 (60) | KTLO-390A-048/480V/** | 15 (7) |
10 | 48 (121) | 56 1/2 (145) | TLO-310A-048/240V/** | 24 7/8 (63) | KTLO-310A-048/240V/** | 16 (7) |
10 | 48 (121) | 56 1/2 (145) | TLO-310A-048/480V/** | 24 7/8 (63) | KTLO-310A-048/480V/** | 16 (7) |
** Add the suffix “3P” to the model number for 3 phase power.
Optional thermostat kits are available to fit into heater terminal box.
PDFs & Manuals
Show Ratings & Reviews
I couldn't find data on fixing of KTLO-360A-048/240. The heater dimension sketch and installation guide. Could you please send it.
Hi Anup
Thank you for the inquiry. Please email this request to TEMP@OMEGA.COM.
Best regards
OMEGA
Date published: 2022-04-15