Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

RH62

Stick Type Rugged Hygrometer & Transducer

Models In Stock
  • One Hand Operation
  • Meter with Backlit LCD Display
  • Max/Data Hold
  • Analog Output Standard 10 mV/1° & 1%RH
RH62
From C$ 234.71
Models In Stock
Stick Type Rugged Hygrometer & Transducer RH62 RH62
loading all models
Product Overview
  • Battery Indication A low battery indication is displayed when the battery voltage drops below the operating level
  • Battery life 200 hr
  • Display Type LCD
  • Display Type Note 3½ digit liquid crystal display (LCD) with maximum reading of 1999.
  • Humidity Sensor Electronic capacitance polymer film
  • Hysteresis ± 1%RH
  • Length 40 mm
  • Measurement Type Relative Humidity, Temperature
  • Measuring Temperature Range, Max 100 °C
  • Measuring Temperature Range, Min -20 °C
  • Operating Temperature Note 0°C to 50°C at <75% relative humidity
  • Relative Humidity Accuracy ± 2.5% RH
  • Relative Humidity Accuracy Note ± 2.5%RH (10% to 90%RH) ± 5%RH ( 90%RH)
  • Relative Humidity Resolution 0.1%RH
  • Response Time 60 sec
  • Sampling Rate 2.5 Hz (2.5 updates/second)
  • Sensor Temperature Dependence Negligible between 0°C to 50°C
  • Stability ± 2%RH
  • Storage Temperature, Max 60 °C
  • Storage Temperature, Min -20 °C
  • Storage Temperature Note -20°C to 60°C at <80% relative humidity.
  • Supply Voltage 6 Vdc
  • Temperature Accuracy ± 0.5 °C
  • Temperature Accuracy Note ± 0.5°C 0°C to 50°C ± 1°C -20°C to 0°C, 50°C to 100°C
  • Temperature Coefficient 0.1 times the applicable accuracy specification per °C from °C to 18°C and 28°C to 50°C
  • Temperature Resolution 0.1 °C
  • Temperature Sensor Type RTD
  • Temperature Sensor Type Note RTD Pt385/1000 Ohm
  • Weight 160 g
  • Weight Note 160g (including probe and batteries)
  • Width 44 mm

Description

RH62C-MV & RH62F-MV Transducer   (no display) Detection elements: Capacitive sensor and Pt385/1000 Ohm RTD sensor, Analog output: 10mV/1° & 1%RH, RH Range: 0.0 to 100.0% over 0 to 50°C , RH Basic accuracy: ± 2.5%,   Connects to any DMM for display via STICK-CABLE ordered separately.

RH62C & RH62F Hygrometer Detection elements: Capacitive sensor & Pt385/1000 Ohm RTD sensor, RH Range: 0.0 to 100.0% over 0 to 50°C, Basic accuracy: ± 2.5%, Backlit LCD Display
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 28ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-CA
en_CA
Save Configuration