Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

TH-10-44006-1/4-2-40

General Purpose Thermistor Probes Stainless Steel Sheath

C$101.45

Item# TH-10-44006-1/4-2-40

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-9 C$101.45
10-24 C$96.38
25-99 C$91.31
100-499 C$86.23
500-999 C$81.16
1000+ C$76.09

In Stock

Lead Time (If not in stock): 4 weeks

Product Specs

<< See all Product Models
Brand
Accuracy ± 0.2 °C (± 0.36 °F)
Cable Length 40 in
Electrical Connection Stripped Leads
Fittings Note Compatible With SSLK and BRLK Compression Fittings
Insulation PFA
Insulation Note 1 m (40") 26 AWG Stranded, PFA Insulated and Jacketed Cable with Stripped Leads Standard
Nominal Resistance 10000 Ω
Probe Diameter 0.25 in
Probe Length 2 in
Probe Type General Purpose Thermistor Probes
Process Temperature, Max 150 °C
Process Temperature, Min -80 °C
Sheath Material 304 Stainless Steel
Temperature Probe Style Immersion Probe
Temperature Sensor Type Thermistor
Thermistor Resistance Temperature, Max 70 °C
Thermistor Resistance Temperature, Min 0 °C
Wire Gauge 26 AWG
Wire Type Stranded
See All Specs Show Less
General Purpose Thermistor Probes Stainless Steel Sheath TH-10-44006-1/4-2-40 TH-10-44006-1/4-2-40
Rated 5 out of 5 by from Engineer Got delivered very fast. Very Accurate measurement
Date published: 2024-05-28
Rated 4 out of 5 by from Good Product with Room for Improvement This part meets almost all of our expectations. They give you plenty of cable to work with. Personally, we cut the cable to about 8 inches of length and put a connector on it for easy replacement. The only downside is there's no strain relief at the probe to cable transition. Our wire got bent back and forth several times over the course of a month and broke off. This kind of damage can not be fixed, requiring us to buy a new part. Overall, great product. Only improvement would be adding strain relief to the transition to prevent failure like this.
Date published: 2019-04-12
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_CA, sid_TH-10-44006-1-4-2-40, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 24ms
  • REVIEWS, PRODUCT
en-CA
en_CA
Save Configuration