Welcome to our new website, found an issue or bug? Please report it here

WT
Bolt-On Thermocouple with SS Washer Housing
Models In Stock
- Very Economically Priced
- J, K, T, and E Thermocouple
- New Rugged Design
- For #6, #8, #10 and 1/4' Screw Sizes
WT
From
C$
26.87
Models In Stock

Product Overview
- Color Code Standard ANSI
- Mounting Bolt-On
- Process Temperature, Min 0 °C
- Wire Gauge 20 AWG
- Wire Type Solid
A versatile thermocouple assembly that easily mounts to a variety of surfaces. Utilizable for a number of surface temperature measurement applications where fixed mounting is possible. | |
Model No. 300 mm (12") L | Model No. 600 mm (24") L | Model No. 900 mm (36") L | Model No. 1500 mm (60") L | Washer Hole Diameter mm (inches) | Nominal Screw Size | |
AMERICAN | METRIC | |||||
GLASS INSULATED | ||||||
WT(*)-6-12 | WT(*)-6-24 | WT(*)-6-36 | WT(*)-6-60 | 3.68 (0.145) | #6 | M3.5 |
WT(*)-8-12 | WT(*)-8-24 | WT(*)-8-36 | WT(*)-8-60 | 4.32 (0.170) | #8 | M4 |
WT(*)-10-12 | WT(*)-10-24 | WT(*)-10-36 | WT(*)-10-60 | 4.95 (0.195) | #10 | M4.5 |
WT(*)-14-12 | WT(*)-14-24 | WT(*)-14-36 | WT(*)-14-60 | 6.60 (0.260) | 1/4 in | M6 |
PFA INSULATED | ||||||
WT(*)-6-12-TT | WT(*)-6-24-TT | WT(*)-6-36-TT | WT(*)-6-60-TT | 3.68 (0.145) | #6 | M3.5 |
WT(*)-8-12-TT | WT(*)-8-24-TT | WT(*)-8-36-TT | WT(*)-8-60-TT | 4.32 (0.170) | #8 | M4 |
WT(*)-10-12-TT | WT(*)-10-24-TT | WT(*)-10-36-TT | WT(*)-10-60-TT | 4.95 (0.195) | #10 | M4.5 |
WT(*)-14-12-TT | WT(*)-14-24-TT | WT(*)-14-36-TT | WT(*)-14-60-TT | 6.60 (0.260) | 1/4 in | M6 |
Washer Dimensions
#6 and #8 screw size: 22 L x 6.5 mm W (0.875 x 0.250")
#10 and 14" screw size: 25 L x 9 mm W (1 x 0.360")
Show Ratings & Reviews
Rated 5 out of
5
by
Audrey Overlie from
Thermocouple perfection
The parts were exactly what the team was looking for in an assembly process
Date published: 2024-01-08
Rated 5 out of
5
by
John B from
Just what we needed
These thermocouples were the form factor we needed for our application. They will work great
Date published: 2023-01-24
Rated 5 out of
5
by
Ray Francis from
just what I needed
the part was out of stock but they still came in a timely manner and worked as excepted, will be a repeat customer
Date published: 2022-11-17
Rated 5 out of
5
by
Harvey Melber from
Rock-On for the Bolt-On Washer!
The part met our specs precisely and was in great condition and appropriately priced.
Date published: 2022-11-03
Rated 5 out of
5
by
TheKAG from
Solid thermocouple
So far so good with this thermocouple. One recommendation I do have, double/triple check the connector before ordering. I thought I ordered the right one, but ended up having to order a replacement. Top to Omega, add images of the termination chosen to the spec wizard.
Date published: 2021-01-04
Rated 5 out of
5
by
Mr Merkin from
Technical staff helped me get all the right parts!
Just what I was looking for! Great support from your technical staff!
Date published: 2020-08-23
What is the outer diameter of the wire with PFA insulation?
The overall nominal outer diameter of the PFA lead wire for the WT series is 0.068 x 0.116".
Date published: 2020-05-10
Does a thermocouple that is designed to be bolted to a surface measure the environment very well? I want to measure the temperature of the air using a similar thermocouple
Thank you for your inquiry C James. You can use a Bolt-On Thermocouple to take air temperature measurements.
Date published: 2022-08-25
Are these Made in Canada or USA ?
Thank you for your inquiry. They made in the USA.
Date published: 2023-10-01
What is meaning of Minimum Temperature Measurement - 60 in
The heading is incorrect for the column and should read "Lead wire length" and it will be corrected.
Date published: 2020-02-17
Can these be used in environments where high EMI/EMF is expected?
It's difficult to say if these probes would be good or not in that type of environment. There is no special shielding and it is a grounded junction probe so any surface it is attached to if it had this energy induced on it would go right into the TC junction. The safest answer is no or experiment at your own discretion.
Date published: 2024-05-17
Hi, is it possible to use wtk-6-12 on an high voltage cable (70 kV) without damaging the measurement system?
The WT series would not be suitable for mounting to a surface with any Voltage as it is a grounded junction and the readings would not be good and it could damage your instrumentation.
Date published: 2024-11-21
Can this be used on a heat press machine for temp sensor
Thank you for your inquiry. Yes it can.
Date published: 2023-01-31
Do these parts meet the requirements of RoHS directive 2015/863/EU?
Thank you for your inquiry. These parts are RoHS Compliant.
Date published: 2022-06-10