1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
FTB4000-Series
Turbine Flow Meter For Water Totalization
Models In Stock
- For Water Flows from 0.15 to 2600 GPM
- Scaled Pulse Output Available for Remote Totalization Indication
- For Hot or Cold Water Applications
- Up to ±1.5% of Reading Accuracy
FTB4000-Series
From
C$
154.00
Models In Stock

Product Overview
- Accuracy ± 1.5 %
- Accuracy Detail From 10% of continuous to maximum flow: ±1.5% of reading; below 10% of continuous flow: ±2% of reading
- Approvals CE
- Display Mechanical Counter
- Height 3.03 in
- Installation 10 pipe diameters upstream, 5 downstream
- Length 5.12 in
- Materials, Wetted Brass, EDPM, Polyimide, Polypropylene, Sapphire, Stainless Steel
- Media Compatibility Liquids
- Operating Pressure, Max 150 psi
- Operating Temperature, Max 90 °C
- Pressure Drop, Max 3.6 psi
- Process Connection Type NPT Male
- Supply Voltage 24 Vac/Vdc
- Volumetric Flow Rate, Min 0.22 GPM
- Weight 0.6 kg
- Width 2.75 in
Specifically designed for water billing applications, OMEGA’s FTB-4000 flowmeters are highly accurate and feature tamper-resistant, non-resettable totalizers. The large faces are easy to read. Optional reed relay scaled pulse outputs allow for remote totalization (1.8 m (6 ft) of cable included). The pulse output option is factory installed and must be requested at the time of order. All FTB flowmeters feature built-in strainers, trickle flow indication and are shipped complete with locking nuts and coupling pieces.
SPECIFICATIONS
Accuracy:
?10% of continuous to max. flow: ± 1.5% of reading
<10% of continuous flow: ± 2% of reading
Power for Pulse Output: 6-16 Vdc
Max. Temp: 90°C (200°F)
Max. Pressure: 150 psi
Pulse Outputs: Reed Relay: 4100P Series: 1 gal/pulse (for remote totalization only)
Max. Reading (gals): 10 million for ½" and ¾"; 100 million for 1", 1¼", 1½"
Wetted Parts: Brass body, stainless steel polyimide (fiberglass), polypropylene, EPDM O-Ring
Installation Requirements: 10 pipe diameters upstream, 5 downstream
Mounting: Horizontal or vertical for ½ " and ¾" models, Horizontal Mounting Required for 1" and 1½" models.
Read More
SPECIFICATIONS
Accuracy:
?10% of continuous to max. flow: ± 1.5% of reading
<10% of continuous flow: ± 2% of reading
Power for Pulse Output: 6-16 Vdc
Max. Temp: 90°C (200°F)
Max. Pressure: 150 psi
Pulse Outputs: Reed Relay: 4100P Series: 1 gal/pulse (for remote totalization only)
Max. Reading (gals): 10 million for ½" and ¾"; 100 million for 1", 1¼", 1½"
Wetted Parts: Brass body, stainless steel polyimide (fiberglass), polypropylene, EPDM O-Ring
Installation Requirements: 10 pipe diameters upstream, 5 downstream
Mounting: Horizontal or vertical for ½ " and ¾" models, Horizontal Mounting Required for 1" and 1½" models.
Model No. | Flow Rate (GPM) | Connection | Lay Length mm (in) | Height mm (in) | Width mm (in) | Pressure Drop (psi) | Weight kg (lb) | Max Temp °C (°F) | ||
---|---|---|---|---|---|---|---|---|---|---|
Min | Cont | Max | ||||||||
FTB-4105A | 0.13 | 6.6 | 13.0 | ½ MNPT | 246 (9.7) | 69.9 (2.75) | 69.9 (2.75) | 3.6 | 0.5 (1.1) | 93.3 (200) |
FTB-4105A-P | 0.13 | 6.6 | 13.0 | ½ MNPT | 246 (9.7) | 69.9 (2.75) | 69.9 (2.75) | 3.6 | 0.5 (1.1) | 93.3 (200) |
FTB-4107A | 0.22 | 11.0 | 20.0 | ¾ MNPT | 257 (10.1) | 77.0 (3.03) | 69.9 (2.75) | 3.6 | 0.6 (1.4) | 93.3 (200) |
FTB-4107A-P | 0.22 | 11.0 | 20.0 | ¾ MNPT | 257 (10.1) | 77.0 (3.03) | 69.9 (2.75) | 3.6 | 0.6 (1.4) | 93.3 (200) |
FTB-4110A | 0.5 | 26.4 | 50.0 | 1 MNPT | 394 (15.5) | 140.0 (5.51) | 91.9 (3.62) | 3.6 | 2.5 (5.5) | 93.3 (200) |
FTB-4115A | 0.8 | 44 | 90 | 1½ MNPT | 447 (17.6) | 140.0 (5.51) | 119.9 (4.72) | 3.6 | 5.5 (12) | 93.3 (200) |
FTB-4120A | 1.3 | 66 | 132 | 2" flange ANSI 150# | 200 (7.9) | 226.1 (8.9) | 154.9 (6.1) | 2.9 | 12.3 (27) | 90.0 (194) |
FTB-4120A-P | 1.3 | 66 | 132 | 2" flange ANSI 150# | 200 (7.9) | 226.1 (8.9) | 154.9 (6.1) | 2.9 | 12.3 (27) | 90.0 (194) |