Welcome to our new website, found an issue or bug? Please report it here

FV500C-Series
Vortex Flow Meters for Industrial Applications
Models In Stock
- Custom Built to Order - CONSULT FLOW ENGINEERING
- SSP (Spectral Signal Processing) Technology
- Measures Steam, Gas, and Low Viscosity Liquids
- Clear Parallel Two-Line LCD Display. Displays Simultaneous Flow Rate and Total Along with Process Diagnosis
FV500C-Series
From
C$
3 400.00
Models In Stock

Product Overview
- Accuracy ± 0.75 %
- Accuracy Note ±0.75% of Reading (Liquid) (±0.5% of Reading: Typical Accuracy/ Non-Guaranteed) ±1% of Reading (Gas, Steam)
- Data Interface BRAIN Communication
- Data Interface Note Communication Signal: BRAIN or HART communication signal (superimposed on a 4 to 20 mA DC signal) Note: HART is a registered trademark of the HART Communication Foundation. Conditions of Communication Line: Load Resistance:250 to 600 Ω(including cable resistance). Supply Voltage:16.4 to 42 V DC for digital communications BRAIN and HART protocols. (16.4 to 30 V DC for intrinsically safe type). BRAIN: Space from other Power Line: 15cm or more (Parallel wiring should be avoided.) Communication Distance: Up to 2 km,when polyethylene insulated PVC- sheathed cables (CEV cables) are used. Communication distance varies depending on type of cable used and wiring. Load Capacitance: 0.22 µF or less Load Inductance: 3.3 mH or less Input Impedance Communicating Device: 10 kΩ or more at 2.4 kHz.
- Electrical Connection Note In case of /FF1 or /CF1, CF11, /KF2, /KS2, /SF2, /SS2 the screw length is deeper than ANSI standard for 0.5 to 2 threads.
- Electrical Output 4 to 20 mA, Two 125 mA SPST SSR
- Enclosure Material N/A
- Enclosure Ratings IP67 Type 4X (IEC 60529)
- Media Compatibility Gases, Liquids, Steam
- Operating Pressure, Max 412 psi
- Operating Temperature, Max 250 °C
- Operating Temperature, Min -29 °C
- Output Detail Pulse output,alarm output and status output use the common terminal, therefore these functions are not used simultaneously. Output Signal (◇): Dual Output (Both Analog and Transistor contact output can be obtained simultaneously). In this case refer to the item “Remarks on installation” for power supply and pulse output wiring. Analog: 4 to 20 mA DC, 2-wire system. Transistor Contact Output*: Open collector, 3-wire system. Pulse,alarm,status output are selected by parameter setting. Contact rating: 10.5 to 30 V DC, 120 mA DC*1 Low level: 0 to 2 V DC. *1: 10.5 to 30 V DC. 80 mA DC for ATEX Intrinsically Safe Approval (/KS2) and IECEx Intrinsically Safe Approval (/SS2)
- Pressure Type Gauge
- Process Connection Type ANSI Flange
- Repeatability ±0.2%
- Supply Power 10.5 to 42 Vdc
- Volumetric Flow Rate, Max 26 GPM
OMEGA’s FV-500C Series vortex flowmeter provides accurate, reliable, low-maintenance flow measurement. Vortices generated by the flowing fluid stress the shedder bar in pulses, and the shedder bar transmits the stress pulses to the encapsulated piezoelectric sensor.
Please contact Omega FLOW Engineering by phone, fax, or email flow@omega.com to size the vortex flow meter for your application. All the vortex meters are custom built to order. A display is highly recommended for any fine tuning adjustments required.
Based on the field proven sensor technology of the FV-500C Series vortex flowmeters, FV-500C features a new amplifier with proprietary spectral signal processing (SSP) technology to analyze the vortex waveform into its spectral components to filter noise from signal for the most stable measurement possible.
The FV-500C Series will provide excellent vibration immunity for stable, accurate measurements at low flows without any need for start-up tuning. The user benefits through greater reliability, reduced maintenance and a lower total cost of ownership.
The programmable display allows access to the full power of OMEGA’s new intelligent amplifier. The display is required if you would like to access the pulse output programming. The display is highly recommend if an adjustment or tweaking is required for the flow measurement application. The display also permits the user to display flow rate and/or total in engineering units for liquids and gases. Rate and total are displayed simultaneously. If the density or enthalpy of the fluid is constant (i.e. the temperature and pressure do not change), the density value can be entered into the meter to display in kilograms, pounds or metric tons; the enthalpy value can be entered to display in BTUs, kilojoules, etc. Analog output span adjustment and low cutoff are also settable from the display, there is no need to adjust pots. The analog and pulse outputs can also be forced to output from 0 to 100% FS or 0 to 6000 Hz without any flow through the meter as a test of the amplifier. For steam flow measurement, the FV-500C can be used with the OMEGA™ FC-20 mass flow computer. The standard FV-500C is wafer-style to slip between 150# ANSI flanges, and comes supplied with extra long bolts for installation. Units with the suffix “-F” have 150# ANSI flanges, 300 lb flange mount is available.
Note: Units with “ -F” suffix have 150 class flange connections, 300 lb flange mount is available if needed.
For units with a display, add “-D” to the part number and $403 to the price.
For units with remote electronics, add “-R” to the part number, subtract $455 from the price, and order the mounting kit and cable below.
For units designed for high temperature use, add “-HT” to the model number and consult engineering for prices.
Please contact Omega FLOW Engineering by phone, fax, or email flow@omega.com to size the vortex flow meter for your application. All the vortex meters are custom built to order. A display is highly recommended for any fine tuning adjustments required.
Based on the field proven sensor technology of the FV-500C Series vortex flowmeters, FV-500C features a new amplifier with proprietary spectral signal processing (SSP) technology to analyze the vortex waveform into its spectral components to filter noise from signal for the most stable measurement possible.
The FV-500C Series will provide excellent vibration immunity for stable, accurate measurements at low flows without any need for start-up tuning. The user benefits through greater reliability, reduced maintenance and a lower total cost of ownership.
The programmable display allows access to the full power of OMEGA’s new intelligent amplifier. The display is required if you would like to access the pulse output programming. The display is highly recommend if an adjustment or tweaking is required for the flow measurement application. The display also permits the user to display flow rate and/or total in engineering units for liquids and gases. Rate and total are displayed simultaneously. If the density or enthalpy of the fluid is constant (i.e. the temperature and pressure do not change), the density value can be entered into the meter to display in kilograms, pounds or metric tons; the enthalpy value can be entered to display in BTUs, kilojoules, etc. Analog output span adjustment and low cutoff are also settable from the display, there is no need to adjust pots. The analog and pulse outputs can also be forced to output from 0 to 100% FS or 0 to 6000 Hz without any flow through the meter as a test of the amplifier. For steam flow measurement, the FV-500C can be used with the OMEGA™ FC-20 mass flow computer. The standard FV-500C is wafer-style to slip between 150# ANSI flanges, and comes supplied with extra long bolts for installation. Units with the suffix “-F” have 150# ANSI flanges, 300 lb flange mount is available.
Note: Units with “ -F” suffix have 150 class flange connections, 300 lb flange mount is available if needed.
For units with a display, add “-D” to the part number and $403 to the price.
For units with remote electronics, add “-R” to the part number, subtract $455 from the price, and order the mounting kit and cable below.
For units designed for high temperature use, add “-HT” to the model number and consult engineering for prices.
PDFs & Manuals
Show Ratings & Reviews
Can this meter be used to measure oxygen flow?
Thanks for your question. Unfortunately, no, this meter was calibrated for use with water. Additionally, this vortex family sensor has been discontinued and is no longer available for purchase with no replacement
Date published: 2025-01-27