Welcome to our new website, found an issue or bug? Please report it here

OM-CP-XTCTemp2000-Srs
X-Series - Multi-channel Thermocouple Datalogger w/ LCD
Models In Stock
- Large Backlit LCD Display
- User-Friendly Front Panel
- Monitor Multiple Points
- Accepts thermocouple types J, K, T, E, R, S, B, N
OM-CP-XTCTemp2000-Srs
From
C$
1 110.02
Models In Stock

Product Overview
- Calibration Digital calibration through software
- Data Interface WiFi
- Data Interface Note USB-A to micro USB cable (included); 460,800 baud
- Electrical Connection Screw Terminal
- Enclosure Aluminium
- Form factor Benchtop
- LED Indicators 1 per channel and 2 status LEDs
- Length 184.15 mm
- Operating Temperature, Max 60 °C
- Operating Temperature, Min -20 °C
- Process Temperature, Max 60 °C
- Process Temperature, Min -20 °C
- Real Time Recording May be used with PC to monitor and record data in real time
- Samples,Max 2000000
- Sampling Rate 1 day
- Sampling Rate Note 4 Hz up to 1 reading every 24 hours
- Software Compatibility Windows® XP/VISTA/7 and 8 (32- and 64-bit)
- Start Modes Adjustable Delay Start, Immediate Start
- Supply Power Type Battery
- Temperature Accuracy ± 0.5 °C
- Temperature Accuracy Note ± 0.5 °C (0 °C to 50 °C) ± 0.9 °F (32 °F to 131 °F)
- Temperature Resolution 0.01 °C
- Temperature Sensor Type Thermocouple
- Thermocouple Resistance, Max 1000 Ω
- Time Accuracy ± 1 minute/month
- Width 65.58 mm
- Wire Gauge 24 AWG
The OM-CP-QUADTCTEMP2000-A2 and OM-CP-OCTTCTEMP2000-A2 are four and eight channel thermocouple data loggers with an LCD screen. The device features on-screen minimum, maximum and average statistics, as well as a user configurable screen that allows for any combination of channels to be displayed. The device accepts J, K, T, E, R, S, B and N type thermocouples.
The OM-CP-QUADTCTEMP2000-A2 and OM-CP-OCTTCTEMP2000-A2 are ideal for a variety of applications, whether it is remote temperature monitoring, or multiple points in a central location. Data from all channels is simultaneously logged and displayed on-screen for real-time monitoring. It can then be downloaded to a PC for further analysis.
INTERNAL CHANNELS | |
---|---|
Temperature Range | -20 °C to +60 °C (-4 °F to +140 °F) |
Temperature Resolution | 0.01 °C (0.018 °F) |
Calibrated Accuracy | ± 0.5 °C (0 °C to 50 °C) ± 0.9 °F (32 °F to 131 °F) |
REMOTE CHANNELS | |
Remote Channel Thermocouple Types | J, K, T, E, R, S, B, N |
Thermocouple Connection | Female subminiature (SMP) |
Cold Junction Compensation | Automatic, based on internal channel |
Maximum Thermocouple Resistance | 1000 „¦, <100 „¦ recommended |
REMOTE CHANNELS | |||
---|---|---|---|
Thermocouple | Range (°C) | Resolution | Accuracy* |
J | -210 to +760 | 0.1 °C | ± 0.5 °C |
K | -270 to +1370 | 0.1 °C | ± 0.5 °C |
T | -270 to +400 | 0.1 °C | ± 0.5 °C |
E | -270 to +980 | 0.1 °C | ± 0.5 °C |
R | -50 to +1760 | 0.5 °C | ± 2.0 °C |
S | -50 to +1760 | 0.5 °C | ± 2.0 °C |
B | +50 to +1820 | 0.5 °C | ± 2.0 °C |
N | -270 to +1300 | 0.1 °C | ± 0.5 °C |
*Thermocouple accuracy specified with 24 AWG diameter thermocouple wires.
GENERAL | |
---|---|
Memory (All channels enabled) | 4-channel: 524,032 readings per channel 8-channel: 262,016 readings per channel |
Start Modes | Software programmable immediate start or delay start, up to 6 months in advance |
Real Time Recording | May be used with PC to monitor and record data in real time |
LEDs | 1 per channel and 2 status LEDs |
Reading Rate | 4 Hz up to 1 reading every 24 hours |
Calibration | Digital calibration through software |
Calibration Date | Automatically recorded within device |
Battery Type | 9 V lithium included, user replaceable |
Battery Life | 18 months typical with display off. 3 months typical with continuous display use. |
Data Format | Date and time stamped °C, °F, K, °R, mV, V |
Time Accuracy | ± 1 minute/month |
Computer Interface | USB-A to micro USB cable (included); 460,800 baud |
Operating System Compatibility | Windows XP SP3/7/8/10 |
Software Compatibility | Standard Software version 4.2.21 or later Secure Software version 4.2.18 or later |
Operating Environment | -20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing |
Dimensions | 4-channel: 7.25 in x 2.70 in x 1.22 in (184.15mm x 65.58 mm x 30.99 mm) 8-channel: 7.25 in x 2.70 in x 1.68 in (184.15mm x 65.58 mm x 42.672 mm) |
Weight | 4-channel: 15.3 oz (435 g) 8-channel: 20.1 oz (569 g) |
Enclosure | Black anodized aluminum |
Approvals | CE |
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews
Does this meet the requirements for AMS2750G
Thank you for your question. Unfortunately, it does not.
Date published: 2022-12-29
Does this controller have any outputs
Thank you for your question. This not a controller just a Datalogger and it does not have outputs just t/c inputs.
Date published: 2022-08-12
Is there a way I can stop/run Datalogger while it is not connected to the computer ?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Date published: 2024-08-14
I have a channel that says Channel unplugged and Channel connected. so my data goes in and out
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Date published: 2023-04-05
How do i change this data logger from mv to temperature. "om-cp-quadtctemp200-a2" it has ambient temp ,all 4 channels read mv i would like it to read temperature
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Date published: 2023-07-06
I have a Fluke 5502 multi-product calibrator. Is there a calibration procedure available I can use to calibrate this device in-house
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM.
Date published: 2022-11-23
Can I edit the Channel title to say something more suitable for any application? I am looking to be able to export the information from the Datalogger without having to edit it in the excel file. Is this possible?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Date published: 2023-03-11