OM-CP-RFCurrent2000A-Series

Wireless Current Data Logger with Display

Models In Stock
  • Wireless Two-Way Communications
  • 20 mA, 160 mA, or 3 A Measurement Ranges
  • Digital Display Provides Instant Access to Current Readings and Statistics
  • Readings Displayed in User Selected Measurement Unit
OM-CP-RFCurrent2000A-Series
From $ 375.00
Models In Stock
Wireless Current Data Logger with Display OM-CP-RFCurrent2000A-Series OM-CP-RFCurrent2000A-Series
loading all models
Product Overview
  • Alarm Note User configurable audible, on-screen, email and text (SMS) alarms, Alarm Delay: A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data, Audible Alarm Functionality: 1 beep per second for reading alarm above/below threshold
  • Band Frequency 2.405 to 2.475 GHz
  • Band Frequency Note ISM band 2.405 to 2.475 GHz operation (channels 11 through 25) @ 250 kbps data rate
  • Battery life 4 yr, typical with reading interval of 15 min
  • Battery Size and Type Li-ion, 9V
  • Baud Rate 250000
  • Calibration Digital Calibration through Software
  • Calibration Date Automated
  • Configuration Omega Engineering Data Recording Software, Windows PC
  • Conversion Time 150 milliseconds
  • Current Resolution 0.01 mA
  • Data Interface Wireless, USB
  • Data Interface Note USB to mini USB, 250,000 baud for standalone operation or OM-CP-RFC1000-EXT/ OM-CP-RFC1000-EXT-EUR/OM-CP-RFC1000-IP69K required for wireless operation
  • Display Type LCD
  • Frequency Rejection 50 to 60 Hz
  • Height 0.95 in
  • Input Type External
  • LED Functionality Green LED blinks every 5 seconds to indicate unit is logging, Blue LED blinks every 15 seconds to indicate unit is in wireless mode, Red LED blinks every 1 second to indicate alarm condition
  • Length 3.5 in
  • Materials Plastic
  • Measurement Type Current
  • Memory Modes Yes
  • Number of Measurements 1
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -20 °C
  • Real Time Recording The device may be used with PC to monitor and record data in real-time
  • Relative Humidity 0 to 95% RH non-condensing
  • Response Time Current: 0.15 sec
  • Response Time Note Current: 0.15 seconds at sensor
  • RF Frequency 2.45 GHz
  • RF Frequency Note 2.45GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication
  • Samples,Max 32256 Samples, Interval Selectable 1 Sec to 24 hrs
  • Sensor Type Current Sensor
  • Software XP SP3/Vista/7 and 8 (32 and 64-bit)
  • Start Modes Delayed Start, Immediate Start
  • Stop Modes Manual via remote software connection, At set date and time, At set Duration
  • Supply Power Note Max Voltage Between Inputs to Ground: 2.5 V
  • Supply Power Type Battery
  • Temperature Coefficient < ± 50 ppm/°C typical
  • Time Accuracy ± 1 minute/month
  • Weight 4.1 oz
  • Width 3.3 in

Description

The OM-CP-RFCURRENT2000A is a wireless data logger with a digital display, designed to measure and record DC current signals. This data logger can connect directly to low-level DC current sources which make it ideal for battery usage studies, energy monitoring studies and other DC current monitoring applications.

The OM-CP-RFCURRENT2000A can also be interfaced with a wide range of current output sensors such as flow meters, pH transmitters and more. Through the software, the device can be programmed with engineering units, which convert the current readings into a different unit of measure such as flow rate. The engineering unit is available for display on the LCD screen as well as in the software. The OM-CP-RFCURRENT2000A is available in 20 mA, 160 mA or 3 A measurement ranges.

The OM-CP-RFCURRENT2000A features an LCD screen which provides instant access to the current reading, minimum, maximum and average statistics. The statistics can be reset through the keypad of the device, allowing customers to keep track of statistics over certain time periods. This feature does not erase the data recorded, but only resets the statistics count. The OM-CP-RFCURRENT2000A can be used as a standalone data logger, or used with the OM-CP-RFC1000-EXT wireless transceiver, to transmit data back to a central PC.

The OM-CP-RFCURRENT2000A transmits up to 152 m (500') line of sight to the OM-CP-RFC1000-EXT transceiver. Multiple OM-CP-RFC1000-EXT’s can be used as repeaters and transmit up to 305 m (1000') line of sight to other OM-CP-RFC1000-EXT’s. This allows the data to be sent over a greater distance.

The OM-CP-RFCURRENT2000A can be used as a single, wireless data logging system, or can be expanded to a large scale system, which can include hundreds of data loggers measuring different parameters such as temperature, humidity and more (additional wireless data loggers and transceivers may be required). The OM-CP-RFCURRENT2000A utilizes the latest software. Data can be viewed in graphical or tabular formats and summary and statistics views are available for further analysis. The software features export to Excel®, data annotation, digital calibration and more.
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 19ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration