Welcome to our new website, found an issue or bug? Please report it here

THS-H-M12
M12 Connector 10,000 Ω Thermistor 3-A Sanitary Probes
- 3-A Approved Design, Along With ASME-BPE-2007 Mounting Flange Geometry, Insures Trouble-Free Cleanability and Interchangeabilty
- Can Be Used in Sanitary, Hygienic, and Clean-In-Place Food, Dairy, Beverage and BioPharmaceutical Processes
- 1/4' Diameter Probe Design for Standard Duty, or
- 3/8' to 3/16' Stepped Probe Design For Heavy Duty Applications

Product Overview
- Accuracy ± 0.2 °C (± 0.36 °F)
- Electrical Connection M12 4 pin Female
- Probe Diameter 0.25 in
- Process Connection Type Tri-Clamp
- Process Temperature, Max 150 °C
- Process Temperature, Min -80 °C
- Sheath Material 316L Stainless Steel
- Temperature Sensor Type Thermistor

In addition to the standard 1½-16AMP process connection, these can be provided in the following sizes and styles:
Process Connection | Model Number Code |
---|---|
3/4"-16AMP | -B1- |
1" and 1½"-16AMP | -D1- |
2"-16AMP | -E1- |
2½"-16AMP | -F1- |
3"-16AMP | -G1- |
4"-16AMP | -H1- |
If you need a process connection that is not listed above, please contact our sales department for availability.
The probe stems are manufactured in two configurations; with a standard ¼" diameter probe for standard duty service, and a stepped 3/8" to 3/16" probe design for good response times in heavy duty applications.
The M12 connector allows for easy connection to your instrumentation by means of an optional extension cable. These sensors are also available as RTD sensing styles to accommodate a wide range of process input requirements. In addition to the standard 1½-16AMP mounting flange, this sensor can be provided in a variety of other flange sizes and styles. If you need something a little (or a lot) different, we can accommodate your needs.
This sensor is stocked with the 10,000 ? thermistor standard, but is available in any of the following resistances:
Sensor Code | Resistance @ 25°C | Element Series |
---|---|---|
2K | 2252 ? | 44004 |
3K | 3000 ? | 44005 |
5K | 5000 ? | 44007 |
10K | 10,000 ? | 44006 |
30K | 30,000 ? | 44008 |