FMA1600-Series

Mass and Volumetric Flow Meters

Models In Stock
  • Ranges of 0 to 0.5 SCCM Up to 0 to 3000 SLM
  • < 10ms Response Time—Field Adjustable
  • 130+ Gas Calibrations with Every Unit: Air, Ar, CH4, CO, CO2, Ethane, H2, He, N2, N2O, Neon, O2, Propane, Butane, Acetylene, Ethylene and more
  • Pressure, Temperature, and Volumetic and Mass Flow Simultaneously Displayed
FMA1600-Series
From $ 1,428.00
Models In Stock
Mass and Volumetric Flow Meters FMA1600-Series FMA1600-Series
loading all models
Product Overview
  • Accuracy ± 0.8 %
  • Accuracy Note ± (0.8% of rdg + 0.2% FS)
  • Additional Features 1 Power Supply Included
  • Calibration NIST 5-Point Certificate
  • Data Interface RS232
  • Display Type LCD
  • Electrical Connection 8-pin mini DIN
  • Height 4.1 in
  • Humidity Range 0 to 100% RH non-condensing
  • Materials, Wetted Aluminum, Brass, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel
  • Measurable Flow Rate 125%
  • Media Compatibility Air, Gases, Nitrogen, Oxygen
  • Operating Pressure, Max 145 psi
  • Operating Pressure, Min 0 psi
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min -10 °C
  • Pressure Drop, Min 1 psi
  • Repeatability ± 0.2%
  • Response Time 10 ms
  • Response Time Note 10 ms typical default response time for 63.2% of a step change. A variable register allows response time to be field adjustable to a certain extent via RS232 communications. The primary trade-off for response time is signal noise
  • Span Shift 0.02% FS/°C/atm
  • Supply Current 35 mA
  • Supply Power Note 35 mA typical current draw; 100 mA available supply recommended
  • Turndown Ratio 200:1
  • Volumetric Flow Rate, Min 0.05 SLM
  • Width 1.1 in
The FMA-1600A Series mass and volumetric Omega's flow meters use the principle of differential pressure within a laminar flow field to determine the mass flow rate. A laminar flow element (LFD) insdie the meter forces the gas into laminar (streamlined) flow. Inside this region, the Poiseuille equation dictates that the volumetric flow rate be linearly related to the pressure drop along a fixed distance of the LFE. This, along with the viscosity of the gas, is used to accurately determine the volumetri flow rate. Separate absolute temperature and pressure sensors are incorporated and correct the volumetric flow rate to a set of standard conditions. This standardized flow rate is commonly called the mass flow rate and is reported in units such as standard cubic feet per minute (SCFM) or standard liters per minute (SLM).

Standard units include a 0 to 5 V output (4 to 20 mA optional) and RS232 communications. The gas select feature can be adjusted from the front of the keypad or via RS232 communications. Volumetric flow, mass flow, or absolute pressure, and temperature can be viewed or recorded through the RS232 connection. It is also possible to multi-drop up to 26 units on the same serial connection to a distance of 125'. These flowmeters are also available in a portable version for use in the field (-B models).

SPECIFICATIONS
Accuracy: ± (0.8% of rdg + 0.2% FS)
Repeatability: ± 0.2%
Turndown Ratio: 200:1
Response Time: 10 ms typical default response time for 63.2% of a step change. A variable register allows response time to be field adjustable to a certain extent via RS232 communications. The primary trade-off for response time is signal noise
Output: 0 to 5 Vdc standard
Operating Temperature: -10 to 50°C (14 to 122°F)
Zero Shift: 0.02% FS/°C/atm
Span Shift: 0.02% FS/°C/atm
Humidity Range: 0 to 100% non-condensing
Pressure (Max):
FMA-1600A Series: 145 psig
FMA-1600A Series: 50 psi differential
FVL-1600A Series: 10 psig
FVL-1600A Series: 10 psi differential
Measurable Flow Rate: 125% FS
Supply Voltage: 7 to 30 Vdc (15 to 30 Vdc for 4 to 20 mA output)
Supply Current: 35 mA typical current draw; 100 mA available supply recommended
Cable Connection: 8-pin mini DIN
Wetted Parts: 303 & 302 Stainless Steel, FKM Heat Cured Silicone Rubber, Glass Reinforced Polyphenylene Sulfide, Heat Cured Epoxy, Aluminum, Gold, Silicon, Glass. Contact Omega engineering for details.
-LSS (Option):316LSS, 303SS, 430FRSS, Perfluoroelastomer standard, FKM, EPDM, Buna, Neoprene Standard Pressure Drops (venting to atmosphere):
Max Flow Rate 0.5 to 50 SCCM 0.1 to 10 SLM 20 SLM 50 SLM 100 SLM 250 SLM 500 SLM 1000 SLM 1500 SLM
PSID 1 1 1 2 2.5 4.0 5.5 6.0 9.0
Rated 4 out of 5 by from Good Mass Flowmeter Easy to setup and reliable. Easy to use. Remote operation needs expert installation but is easy to use after setup. Price could be lower to have a broader application.
Date published: 2016-11-17
Rated 5 out of 5 by from Flow meter Omega flow meter works as described for use in a test laboratory
Date published: 2025-01-26
Rated 5 out of 5 by from Accurate and reliable Bought this flow meter to measure and calibrate the flow rate of Helium and Argon for a protein analyzer instrument. Without the meter, it's virtually impossible to know the exactly flow rate to calibrate it since the instrument doesn't response to change in flow rate. We waste a lot of precious Helium gas due to that. Now that it's calibrated, we can save money in the long run. Awesome!
Date published: 2024-07-31
Rated 5 out of 5 by from High performance flow meters My laboratory have ordered 2 1617A and 4 1619A flow meters and been satisfied with their performance.
Date published: 2023-12-17
Rated 3 out of 5 by from Need better software IT works well, but would love to see a better user interface to connect it to PC. Using PuTTY kind of sucks.
Date published: 2023-08-07
Rated 5 out of 5 by from Highly recommend Great product! I was worried this wouldn't arrive in time for when it was needed but very quick!
Date published: 2023-07-26
Rated 5 out of 5 by from As Advertised Worked as advertised. No issues. seems robust for out testing environment
Date published: 2023-03-20
Rated 3 out of 5 by from 2 units defective out of box The negative terminal was shorted to the body of the sensor and would not work unless the sensor was installed isolated from ground, which we couldn't do in our application. They are easy to disassemble, and the problem was obvious, as one of the wires that connects to the terminal extended about 1/2" past the point that it was soldered at, so the bare wire came into contact with the body of the sensor when it was assembled.
Date published: 2023-01-05
  • y_2025, m_2, d_21, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_10
  • loc_en_US, sid_FMA-1601A, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT

hi how i can connect it to o2 generator @65 psi thank you

Asked by: asdsand
Hi, you may connect to the mass flow meter via a machine thread or NPT connection with sufficient straight run pipe or tubing, 10x the diameter of the pipe or tube upstream and 5x the diameter of the pipe or tubing downstream.
Answered by: Application Engineer JC
Date published: 2019-08-06

What are the voltage levels of the RS232 signals? -12V to +12V?

Asked by: Dydos
Thank you for your inquiry. The mass flow meters have by factory default a 0 to 5V signal output or as an option a 4 to 20 mA and the RS232 is available as serial communication.
Answered by: Application Engineer JC
Date published: 2022-10-19

Hi, is FMA-1601A usable for LPG with H2S and RSH mixture?

Asked by: Tarek
Thank you for your inquiry about the mass flow meter. There is an option listed in themanual for the '-LSS' version that handles corrosive gases such as the H2S listed. You may submit a request for a quote to flow@omega.com with the estmated flow range to prepare the part number required.
Answered by: Application Engineer JC
Date published: 2022-12-03

What is the minimum inlet pressure of the 0-5 SLPM model?

Asked by: jr454
Thank you for your inquiry. The minimum pressure required is 1 PSI
Answered by: Applications Engineer JJC
Date published: 2024-08-07

Can this sensor measure the flow rate of a duct with a mixture of air, dust, and particles? Is this sensor compatible with the program NodeRED?

Asked by: boopinator
Thank you for your inquiry. It is not recommended to have suspended particles in the air stream and will result in clogging the internal flow path and cause damage. This flow meter requires that the air flow be clean and dry and if the NodeRED can accept an analog input from the flow meter's output, yes.
Answered by: Applications Engineer JJC
Date published: 2024-12-09

I am interested in using Modbus protocol via RS232/RS485 to poll data from this instrument. Is this possible? And if so, what register address corresponds to what type of data (ie Mass flow, Volumetric flow, Pressure and Temperature)?

Asked by: AI70
Thank you for your inquiry. The manual for the MODBUS communication protocol is found in the Downloads &amp; Software Manuals Tab.
Answered by: Applications Engineer JJC
Date published: 2024-02-11

Hi, does this flow meter work for steam at low vapor pressure (&lt; 1 psia)?

Asked by: ywt12138
Thank you for your inquiry. Unfortunately, the mass flow meter is best for only clean, dry gases, not for steam applications.
Answered by: Applications Engineer JJC
Date published: 2025-02-14

Can you confirm the resolution of each meter is 0.01% of full scale range or better?

Asked by: jmadvint
Thank you for your inquiry. Please email the Flow Group at flow@dwyeromega.com and can advise.
Answered by: Applications Engineer JJC
Date published: 2024-04-26
  • y_2025, m_2, d_21, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_25
  • loc_en_US, sid_FMA-1601A, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 11ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration