Welcome to our new website, found an issue or bug? Please report it here
PX409-16BI
16 to 32 inHg, Barometric, 4 to 20 mA, 1/4" NPT Male, Cable, (-49 to 240 °F)

Choose a Variant
Electrical Connection
Electrical Output
Pressure Type
Pressure, Max
Pressure, Min
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-9 | $1,220.07 |
10-24 | $1,159.07 |
25-49 | $1,134.67 |
50-99 | $1,085.86 |
100+ | $1,061.46 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product ModelsBrand |
![]() |
Accuracy | ± 0.08 % |
Accuracy Class | < 0.1% |
Accuracy Note | (CombinedLinearity,Hysteresis and Repeatability):± 0.08% BSL maximum Compound ranges calibrated only in positive direction |
Additional Features 1 | None |
Bandwidth | DC to 1 kHz |
Cable Length | 2 m |
Compliance | RoHS 2 |
Electrical Connection | Cable |
Electrical Output | 4 to 20 mA |
Electrical Output Note | None |
Enclosure Ratings | IP67 |
Insulation Resistance | 100 MΩ @ 50 Vdc |
Materials, Wetted | 316L Stainless Steel |
Operating Temperature, Max | 115 °C |
Operating Temperature, Min | -45 °C |
Output Signal | Current |
Pressure Cycles | 1 million, minimum |
Pressure Type | Barometric |
Pressure, Max | 32 inHg |
Pressure, Min | 16 inHg |
Process Connection Size | 1/4 in |
Process Connection Type | NPT Male |
Response Time | <1 ms |
Shock | 50 g, 11 ms half-sine |
Span Setting Adjustable Range | ± 0.5% FS typical 1% maximum (1% typical, 2% maximum for 2.5 psi and below). Calibrated in vertical direction with fitting down |
Stability | ± 0.1% |
Stability Note | Long Term Stability (1-Year): ± 0.1% FS typical |
Supply Power Note | Supply Voltage: 9 to 30 Vdc maximum loop res Ω = (Vs-9)x50 [9 to 20 Vdc above 105°C (229°F)] |
Supply Voltage | 9 to 30 Vdc |
Vibration | 5-2000-5 Hz, 30 minute cycle,Curve L, Mil-Spec 810 figure 514-2-2, vertical and horizontal axis |
Weight | 200 g |
Zero/Balance Error | ± 0.5% |
Zero/Balance Error Note | ± 0.5% FS typical 1% maximum (1% typical, 2% maximum for 2.5 psi and below) |
See All Specs |
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews
Rated 5 out of
5
by
Ali Mohammed from
Exceptional Performance and Reliability
I am thoroughly impressed with the performance of the presssure transducer. The transducer offers exceptional resolution, capable of detecting even the smallest leaks. The device was easy to integrate into our system, and the user manual provided clear instructions. Since its installation, it has consistently delivered precise and reliable readings. Overall, I am extremely satisfied with this Omega Engineering pressure transducer and highly recommend it for its high resolution, robust build, and consistent performance.
Date published: 2024-07-14
Rated 5 out of
5
by
NDPIII from
Nice Unit
Works great on our test stand , withstands plenty of abuse .
Date published: 2024-07-11
Rated 5 out of
5
by
Ted R from
Top notch
The quality of the signal and the precision are excellent. Also, the build quality is also very good.
Date published: 2023-02-24
Rated 4 out of
5
by
Trash from
Accurate Readings
The sensor provides precise absolute pressure measurements from 0 to 30 psi, making it highly reliable for various applications.
Date published: 2025-02-17
Rated 5 out of
5
by
Jerry Gu from
presdient
been with Omega for over 15 years. very stable, reliable
Date published: 2025-02-08
Rated 5 out of
5
by
Karl S from
Fantastic transducer!
Great transducer at a very good price point, with reasonable lead times!
Date published: 2024-11-11
Rated 5 out of
5
by
Karl S from
Great transducers
Simple, easy to use, accurate, quick lead times, and a fraction of the price of competitors!
Date published: 2024-11-04
Rated 4 out of
5
by
Maria S from
reliable but mediocre structural integrity
generally the npt threads are quite weak and we have sheared off multiple from the bodies of the sensors
Date published: 2024-10-12