Welcome to our new website, found an issue or bug? Please report it here

JMQSS
Thermocouple Probes with Molded Miniature Connectors
Models In Stock
- 6' and 12' Lengths in StocK
- Sheath Diameters from 0.010' to 0.125'
- 304SS or 321SS Sheath
- Grounded, Ungrounded or Exposed Junction
JMQSS
From
$
24.21
Models In Stock

Can't find the right model?
Use our custom configurator to fine tune your product
Product Overview
- Cable Clamp PCLM-SMP
- Connector Temperature, Min 0 °C
- Electrical Connection Miniature Male Thermocouple Connector
- Mating Connector Miniature Female Thermocouple Connector
- Process Connection Size N/A
- Process Temperature, Min 0 °C
- Safety Clip SMCL
- Temperature Sensor Type Thermocouple
OMEGA's Quick Disconnect Thermocouples with Miniature Connectors are high quality, economical thermocouple probes. They feature a glass filled nylon connector which is rated for temperatures up to 220°C(425°F). The probes are available in with diameters as small as 0.25mm(0.010 inches) and as large as to 3.0mm(0.125 inches).

Standard Dimensions - Mini Quick Disconnect Probes
*Specify junction type: E (exposed), G (grounded) or U (ungrounded). Other lengths available, consult Sales Department. To order with Inconel Sheath, Change "SS" in model no. to "IN". No additional charge.
Want to learn more about thermocouples? Read our thermocouple tutorial page!
Learn about selecting the thermocouple junction.
View the Thermocouple Accuracy and Color Code charts

Standard Dimensions - Mini Quick Disconnect Probes
Alloy/ANSI Color Code | Sheath Dia. inches | Model No. 6" Length | Model No. 12" Length |
J Iron-Constantan 304 SS Sheath | 0.010 0.020 0.032 0.040 0.062 0.125 | SICSS-010(*)-6 SICSS-020(*)-6 SICSS-032(*)-6 JMQSS-040(*)-6 JMQSS-062(*)-6 JMQSS-125(*)-6 | SICSS-010(*)-12 SICSS-020(*)-12 SICSS-032(*)-12 JMQSS-040(*)-12 JMQSS-062(*)-12 JMQSS-125(*)-12 |
K CHROMEGA™-ALOMEGA™ 304 SS Sheath | 0.010 0.020 0.032 0.040 0.062 0.125 | SCASS-010(*)-6 SCASS-020(*)-6 SCASS-032(*)-6 KMQSS-040(*)-6 KMQSS-062(*)-6 KMQSS-125(*)-6 | SCASS-010(*)-10 SCASS-020(*)-12 SCASS-032(*)-12 KMQSS-040(*)-12 KMQSS-062(*)-12 KMQSS-125(*)-12 |
K CHROMEGA™-ALOMEGA™ Super OMEGACLAD™ XL Sheath Sheath | 0.010 0.020 0.032 0.040 0.062 0.125 | SCAXL-010(*)-6 SCAXL-020(*)-6 SCAXL-032(*)-6 KMQXL-040(*)-6 KMQXL-062(*)-6 KMQXL-125(*)-6 | SCAXL-010(*)-10 SCAXL-020(*)-12 SCAXL-032(*)-12 KMQXL-040(*)-12 KMQXL-062(*)-12 KMQXL-125(*)-12 |
N OMEGA-P™-OMEGA-N™ Super OMEGACLAD™ XL Sheath | 0.020 0.032 0.040 0.062 0.125 | SNNXL-020(*)-6 SNNXL-032(*)-6 NMQXL-040(*)-6 NMQXL-062(*)-6 NMQXL-125(*)-6 | SNNXL-020(*)-12 SNNXL-032(*)-12 NMQXL-040(*)-12 NMQXL-062(*)-12 NMQXL-125(*)-12 |
E CHROMEGA™-Constantan 304 SS Sheath | 0.010 0.020 0.032 0.040 0.062 0.125 | SCXSS-010(*)-6 SCXSS-020(*)-6 SCXSS-032(*)-6 EMQSS-040(*)-6 EMQSS-062(*)-6 EMQSS-125(*)-6 | SCXSS-010(*)-12 SCXSS-020(*)-12 SCXSS-032(*)-12 EMQSS-040(*)-12 EMQSS-062(*)-12 EMQSS-125(*)-12 |
T Copper-Constantan 304 SS Sheath | 0.020 0.032 0.040 0.062 0.125 | SCPSS-020(*)-6 SCPSS-032(*)-6 TMQSS-040(*)-6 TMQSS-062(*)-6 TMQSS-125(*)-6 | SCPSS-020(*)-12 SCPSS-032(*)-12 TMQSS-040(*)-12 TMQSS-062(*)-12 TMQSS-125(*)-12 |
N OMEGALLOY™ Inconel 600 Sheath | 0.010 0.020 0.032 0.040 0.062 0.125 | SNNIN-010(*)-6 SNNIN-020(*)-6 SNNIN-032(*)-6 NMQIN-040(*)-6 NMQIN-062(*)-6 NMQIN-125(*)-6 | SNNIN-010(*)-12 SNNIN-020(*)-12 SNNIN-032(*)-12 NMQIN-040(*)-12 NMQIN-062(*)-12 NMQIN-125(*)-12 |
Want to learn more about thermocouples? Read our thermocouple tutorial page!
Learn about selecting the thermocouple junction.
View the Thermocouple Accuracy and Color Code charts
Probes up to 48 inches in length are shipped "straight." Probes over 48 inches are shipped "coiled". If probe above 48 inches in length must ship straight, please add "-SST" to the end of the part number, and add $75.00 to the probe cost. Additional shipping fees from carrier may also apply for non-standard length packaging.
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
elbird from
Great service!
We order from Omega on a regular basis. They almost always have the exact part we were looking for and we always receive our orders in a very timely manner in the condition expected. Top notch.
Date published: 2017-07-06
Rated 5 out of
5
by
Rachel Castellano from
Timely shipping for a timely needed product
Thermocouples that arrive on time, with no abnormalities and never have to be returned.
Date published: 2023-07-19
Rated 5 out of
5
by
JamesM from
Sturdy and Accurate
Have used these products over the years and they have always been reliable and sturdy despite the abuse they get.
Date published: 2022-09-12
Rated 5 out of
5
by
Dock from
Quick Disconnect Thermocouples
Much like all of the other OMEGA products I have used over the years these TC's are a GREAT PRODUCT! Your new website is awful!
Date published: 2020-05-13
Rated 3 out of
5
by
MacKKev from
Disappointed that the mini connector is separate.
My company has been purchasing this Tcouple for decades. The latest batch came with no connectors. Nobody informed us at time of purchase, and we were charge for rush shipping to a customer that was unhappy with the delay.
Date published: 2018-09-16
Rated 5 out of
5
by
VJTC from
Accurate
Works well for what I needed it for - pharmaceutical products.
Date published: 2024-12-05
Rated 5 out of
5
by
SteveSS from
Quality branded products and fantastic service
Excellent product! Fast delivery and friendly service!
Date published: 2024-10-14
Rated 5 out of
5
by
T R C from
Exactly as pictured and arrived quickly
Exactly as pictured and arrived quickly. Worked perfectly for need.
Date published: 2024-08-12
when would I use a grounded versus ungrounded thermocouple?
Thank you for your inquiry David W. You would use grounded when there is no risk of any electrical noise affecting your measurement and you want a fast time response. You will used ungrounded to minimize the electrical noise on the system however your time response will be slower.
Date published: 2022-05-04
What is the response time
Thermocouple response time is a function of the probe diameter and the junction type such as Grounded, Ungrounded and Exposed. The link attached will help you determine the response times of various diameters of thermocouples with the three aforementioned junction types.
https://www.omega.co.uk/temperature/Z/ThermocoupleResponseTime.html
Date published: 2020-03-13
Do you have guidelines for minimum bend radius? I'm not seeing any in the datasheet.
The minimum bend radius would be 2 times the probes diameter.
Date published: 2023-03-14
Does this item include the female connector?
Thank you for your inquiry. These products do not come with the female miniature mating connector. Sold separately.
Click Here: https://www.omega.com/en-us/temperature-measurement/temperature-connectors-panels-and-block-assemblies/c/temperature-connectors?view=list
Date published: 2023-08-24
I am using the probes with temperature range of 0-260 degC. I make sure the tip is always measuring within range. But, some portion of the sheath far away from the tip may be under a higher temperature, say 300 degC. Is this okay?
Thank you for your inquiry. No the temperature range of the entire sheath is 0 to 260 C. If you exposed any part of the probe to a temperature higher than the rated temperature, it will lead the probe to have a reduce lifetime and failed prematurely. If you need to measure higher temperatures, please get a probe rated for that maximum temperature.
Date published: 2024-02-11
What is a maximum diameter of the cable connected to the TC? Could you recommend a cable to connect the TC for length of 80m aprox.?
There is no cable or lead wires attached to the probe. You will need to use a mating female connector and extension wire to extend the run of your circuit. The mating connectors can only handle up to a 20 gauge wire. The maximum distance you can run a type E 20 gauge thermocouple wire is 140'.
Date published: 2020-03-20
Are your assemblies with exposed junction considered pressure / vacuum tight up to the connector? I want to install one in a vacuum oven. Have used sealed probes before, but need quicker response with exposed junction.
Hello, thank you for your question.
Although the probe is epoxy sealed we do not recommend using ones with exposed junctions in a vacuum environment because air will leak through from the the outside connector side of the probe into the vacuum.
Date published: 2020-07-11
for the these thermocouple probes with immersion, can i isolate a part of it and let just a little part non isolated for the measurement. Does this procedure affect the accuracy and the calibration or i should immerge all the probe to get good results.
Thank you for your inquiry mouna1992. The thermocouple junction that makes up the sensor is located at the tip of the probe which needs to be immersed into the material at all times for accurate temperature measurements. Taking into account this fact, you do not need to fully immersed the probe into the medium. You can immersed most of the length of the probe without any effects on the accuracy as you describe on your question.
Date published: 2024-02-11