Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici
DP6000-7H0
1/8 DIN Process Panel Meter

Choisissez une variante
Output Configurations
Input Type
Supply Voltage
Control Output
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-9 | C$1,107.97 |
10-24 | C$1,052.57 |
25-49 | C$997.17 |
50-99 | C$941.77 |
100-499 | C$886.38 |
500+ | C$830.98 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
Spécifications du produit
<< Voir toutes les modèles de produitsBrand |
![]() |
Additional Features 1 | Sunlight Readable |
Baud Rate | 300 to 19200 |
Calibration | Calibrated at the factory. Recalibration is recommended at least every 12 months |
Category of Overvoltage | II |
Category of Overvoltage Note | Installation overvoltage category II; local level with smaller transient overvoltages than installation overvoltage category III |
Control Output | None |
Data Interface | Modbus RTU |
Data Interface Note | Protocol: Modbus RTU Meter Address/Slave ID: 1 – 247 Baud Rate: 300 to 19,200 bps Transmit Time Delay: Programmable between 0 and 199 ms Data: 8 bit (1 start bit, 1 or 2 stop bits) Parity: Even, odd, or none with 1 or 2 stop bits Byte-to-Byte Timeout: 0.01 to 2.54 seconds Turn Around Delay: Less than 2 ms (fixed) |
Digital I/O Note | Channels: 4 digital inputs and 4 digital outputs per module System: Up to 2 modules for a total of 8 inputs and 8 outputs Digital Input Logic: High: 3 to 5 Vdc Low: 0 to 1.25 Vdc Digital Output Logic: High: 3.1 to 3.3 Vdc Low: 0 to 0.4 Vdc Source Current: 10 mA maximum Sink Current: 1.5 mA minimum +5 V Terminal: To be used as pull-up for digital inputs only |
Display Color | Red |
Display Size | 15 mm (0.60 in) |
Display Type | 6 Digit Dual - Line -Sunlight Readable |
Display Type Note | Both displays are 6 digits (-99999 to 999999), red LEDs with leading zero blanking Upper Display: 15 mm (0.60") high Lower Display: 12 mm (0.46") high Display Intensity: 8 intensity levels Display Update Rate: 5 per second Overrange: Display flashes 999999 Underrange: Display flashes -99999 Display Assignment: The upper and lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max and min, set points, units (lower display only), or Modbus input |
Electrical Connection | Screw Terminal |
Electrical Connection Note | Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/o, and serial communication adaptors |
Enclosure Material | Plastic |
Enclosure Ratings | IP65, NEMA Type 4X |
Form factor | 1/8 DIN |
Functions | Noise Filter: Programmable from 2 to 199 (0 will disable filter) ;Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span ;Cyber Security: 3 programmable passwords restrict modification of programmed settings; Pass 1: Allows use of function keys and digital inputs; Pass 2: Allows use of function keys, digital inputs and editing set/ reset points; Pass 3: Restricts all programming, function keys, and digital inputs |
Fuse Rating | 5 A delayed |
Height | 62 mm |
Input Type | Current, Voltage |
Input Type Note | Input: Field selectable: 0 to 20 mA, 4 to 20 mA, ±10 Vdc (0 to 5, 1 to 5, 0 to 10V), MoDbuS PV (slave) Accuracy: ±0.03% of calibrated span ±1 count, square root and programmable exponent accuracy range: 10 to 100% of calibrated span Temperature Drift: 0.005% of calibrated span/°C max from 0 to 65°C ambient, 0.01% of calibrated span/°C max from -40 to 0°C ambient Signal Input Conditioning Function: Linear, square root, programmable exponent, or round horizontal tank volume calculation Multi-Point Linearization: 2 to 32 points for PV or PV1; 2 to 8 points for PV2 (dual-scale level feature) Programmable Exponent: 1.0001 to 2.9999 Low-Flow Cutoff: 0 to 999999 (0 disables cutoff function) Decimal Point: Up to 5 decimal places or none: d.ddddd, dd.dddd, ddd.ddd, dddd.dd, ddddd.d, or dddddd Calibration Range: 4 to 20 mA: Minimum span; input 1 and Input 2: 0.15 mA ±10 V: Minimum span; input 1 and 2: 0.10 V An Error message will appear if input 1 and input 2 signals are too close together Input Impedance: Voltage Ranges: Greater than 1 MΩ Current Ranges: 50 to 100 Ω (depending on resettable fuse impedance) Input Overload: Current input protected by resettable fuse, 30 Vdc max; fuse resets automatically after fault is removed |
Isolation | 4 kV input/output-to-power line; 500 V input-to-output or output-to-P+ supply |
Length | 143 mm |
Memory | Non-Volatile Memory : All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost |
Mounting | 1/8 DIN panel cutout required: 92 x 45 mm (3.622 x 1.772"); two panel mounting bracket assemblies are provided |
Normal Mode Rejection | Greater than 60 db at 50/60 Hz |
Number of Inputs | 1 |
Operating Temperature, Max | 65 °C |
Operating Temperature, Min | -40 °C |
Output Configurations | None |
Programmable Functions | Filter Bypass, Noise Filter, Security |
Programming | 4 front panel buttons, digital inputs, PC and software, Modbus registers, or cloning using copy function |
Relative Humidity | 0 to 90% non-condensing |
Sampling Rate | 5 Hz (5 updates/second) |
Storage Temperature, Max | 85 °C |
Storage Temperature, Min | -40 °C |
Supply Power Note | 85 to 265 Vac 50/60 Hz, 90 to 265 Vdc, 20 W max, or jumper selectable 12/24 Vdc ±10%, 15 W max Isolated Transmitter Power Supply: 24 Vdc ±5% @ 200 mA max (standard), (12/24 Vdc powered models rated @ 100 mA max); 5 or 10 Vdc @ 50 mA max, selectable with internal jumper J4 |
Supply Power Type | DC |
Supply Voltage | 12 to 24 Vdc |
Tightening Torque | Screw terminal connectors: 5 lb-in |
Weight | 269 g |
Width | 119 mm |
Wire Gauge | 22 to 12 AWG |
Voir toutes Spécs |
Afficher les notes et les avis