DP41-U

1/8 DIN High Performance Temperature, Process and Strain Meter

C$1,581.48

Article# DP41-U

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$1,581.48
5-9 C$1,502.41
10-24 C$1,423.33
25-49 C$1,344.26
50-99 C$1,265.18
100+ C$1,186.11

En stock

Délai de livraison (si pas en stock): 6 semaines

Spécifications du produit

<< Voir toutes les modèles de produits
Brand
A/D Conversion Dual-slope technique
Accuracy ± 0.005 %
Common Mode Rejection 120 dB
Common Mode Voltage 1500 Vp per HV test
Control Output None
Current Measurement Range 0 to 20 mA, 4 to 20 mA
Cutout Dimensions 45 x 92 mm
Data Interface N/A
Display Color Red, Green
Display Size 13.7 mm (0.54 in)
Display Type 6 Digit Single LED
Display Type Note Red or green 6-digit, 14-segment, 13.7 mm (0.54") high; 4 alarm indicators
Enclosure Ratings IP65, NEMA Type 4
Form factor 1/8 DIN
Height 48 mm
Input Configuration Single-ended
Input Type Universal Input Indicator
Input Type Note Thermocouple, RTD, Analog Current/Volatge, Strain
Length 165 mm
Normal Mode Rejection 60 dB
Number of Inputs 1
Offset Adjustment 0 to 999,999 or 0 to -99,999, programmable
Operating Temperature, Max 50 °C
Operating Temperature, Min 0 °C
Output Configurations None
Output Configurations Note None
Output Detail Isolated, tri-state, TTL/CMOS compatible; external 5V supply required for isolated; internal 5V supply for non-isolated
Polarity Unipolar/Bipolar, programmable
Power Consumption 10 W
Power Consumption Note 6 W nom., 10 W max
Reading Rate 3/s or 13/s, 60 Hz; 3/s or 12/s, 50 Hz
Relative Humidity 95% RH, non-condensing
Resolution 15-bit
Sampling Rate 13 Hz (13 updates/second)
Sensor Break Protection Up-scale or down-scale, programmable
Sensor/Transmitter Power 10 V at 30 mA; 24V at 25 mA
Setpoint 4 isolated open collector; rated 150 mA at 1V sink, 30V open
Span Adjustment 0.00001 to 500,000 counts, programmable
Step Response 1 sec to 99.9%
Storage Temperature, Max 85 °C
Storage Temperature, Min -40 °C
Supply Power Note 115 or 230 Vac, 49 to 400 Hz; 10 to 32 Vdc
Supply Power Type AC
Supply Voltage 115 to 230 Vac
Temperature Measurement Range Type J: -210 to 760°C,Type K: -270 to 1372°C,Type T: -270 to 400°C,Type E: -270 to 1000°C,Type R/S: -50 to 1300°C,Type B: 100 to 1820°C,Type N: -270 to 1300°C,Type J DIN: -200 to 900°C,RTD 1: -200 to 200°C,RTD 2: -200 to 900°C,RTD 3: -200 to 850°C
Thermal Span Effect ±20 ppm
Voltage Measurement Range 6 to 100 mV, 0 to 1V, 0 to 5V, 1 to 5V, 0 to 10V, 0 to 100V, ±50 mV, ±500 mV, ±5V, ±50V
Warm-Up to Rated Accuracy 50 min
Weight 574 g
Width 96 mm
Voir toutes Spécs Montrer moins
1/8 DIN High Performance Temperature, Process and Strain Meter DP41-U DP41-U
Rated 1 out of 5 by from Garbage The scaling is a "unique" process, wherein a simple zero point and span point will not be sufficient, and a scaling and offset coefficient will need to be altered for correct span value and zero/null reading respectively. This isn't inline with industry standards. Where most other instrument manufactures have implemented such a basic function as two point linearity, the DP-41 requires extra steps. It has a two point linearity feature, however it simply doesn't work. After designating a zero and span value, and returning to operation mode, the applied values from adjustment will not match the meter display. This was confirmed in calibration lab on a calibrated bench meter (34401A) and a power supply (6115A). What's more, if the 2 point scaling procedure is done multiple times, the parameters will change by a large margin (we saw about a 350% error between scaling procedures, performing the operation 20 times). This isn't random; the error occurs every other time. Again, two point scaling is a very basic function of most instrumentation that the DP-41 fails at accomplishing.
Date published: 2023-02-02
Rated 5 out of 5 by from Quality parts Thank you for the quick shipping of this item and Omega always provide reliable parts needed for our test area.
Date published: 2021-04-15
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_CA, sid_DP41-U, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
fr-CA
fr
Enregistrer la configuration