Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

HH74K-Series
1 Channel Mini K Type Thermocouple Meter
Modèles en stock
- Lightweight Design
- MAX/DATA HOLD Function
- Auto Power Off Function Can Be Disabled
- Battery Life 300 Hrs. Typical Use
HH74K-Series
Depuis
C$
127.44
Modèles en stock

L'aperçu du produit
- Additional Features 1 Max/ HOLD Functions, Auto Power off, Adjustable Offset
- Applications Art and Museums, Environmental and Weather, Laboratories and Scientific, Office and Commercial
- Battery Indication “+ -” is displayed when battery voltage drops below operating level
- Battery life 300 hr
- Electrical Connection Miniature Male Thermocouple Connector
- Height 148 mm
- Length 24 mm
- Measuring Temperature Range, Max 850 °C
- Measuring Temperature Range, Min -100 °C
- Number of Channels 1
- Operating Temperature Note 0 to 50°C (32 to 122°F) <70% RH
- Sampling Rate 2.5 Hz (2.5 updates/second)
- Storage Temperature, Max 60 °C
- Storage Temperature, Min -20 °C
- Storage Temperature Note -20 to 60°C (-4 to140°F), 0 to 80% RH with battery removed from meter
- Supply Power Note Three 1.5V “AAA” (included)
- Supply Power Type Battery
- Supply Voltage 4.5 Vdc
- Temperature Accuracy ± 0.3%
- Temperature Accuracy Note Accuracy (Does Not Include Probe): 18 to 28°C (64 to 82°F) ambient ± (0.3% rdg + 1°C) on °C ranges ± (0.3% rdg + 2°F) on °F ranges Stated Accuracy: 23 ± 5°C (73 ± 9°F), <75% RH
- Temperature Resolution 0.1 °C
- Temperature Resolution Note 0.1°C -59.9 to 199.9°C; 1°C -100 to -60°C; 200 to 850°C 0.1°F -59.9 to 199.9°F 1°F -148 to -60°F 200 to 1562°F
- Temperature Sensor Type Thermocouple
- Thermocouple Type K
- Weight 74 g
- Weight Note Approximately 74 g (2.6 oz) with battery
- Width 48 mm
SPECIFICATIONS
Display:
3/12 digit liquid crystal display(LCD)
Low Battery Indication: indicator
Measurement Rate: 1.5 times/second
Operating Environment: 0 to 50 Deg.C (32 to 122 Deg.F) <70% R.H.
Storage Environment: -20 to 60 Deg.C (-4 to 140 Deg.F), 0 to 80% R.H. with battery removed from meter
Accuracy: Stated accuracy at 23 +/- 5Deg.C (73 +/- 9Deg.F), <75% R.H.
Battery: 1.5V x 3pcs AAA size, included
Battery Life: 300 hours, typical use
Temperature: Range: -100 to 850 Deg.C (-148 to 1562 Deg.F) type K (CHROMEGAR-ALOMEGA)
Resolution:
1 Deg.C or 1Deg.F, 0.1 Deg.C or 0.1 Deg.F
Accuracy (does not include probe):
18 to 28 Deg.C (64 to 82 Deg.F) ambient
+/-(0.3% rdg + 1 Deg.C) on Deg.C ranges
+/-(0.3% rdg + 2 Deg.F) on Deg.F ranges
Resolution: 0.1 Deg.C Range: -59.9 to 199.9°C
Resolution: 1 Deg.C Range: -100 to -60°C, 200 to 850°C
Resolution: 0.1 Deg.F Range:-59.9 to 199.9 Deg.F
Resolution: 1 Deg.F Range:-148 to -60 Deg.F, 200 to 1562 Deg.F
Display:
3/12 digit liquid crystal display(LCD)
Low Battery Indication: indicator
Measurement Rate: 1.5 times/second
Operating Environment: 0 to 50 Deg.C (32 to 122 Deg.F) <70% R.H.
Storage Environment: -20 to 60 Deg.C (-4 to 140 Deg.F), 0 to 80% R.H. with battery removed from meter
Accuracy: Stated accuracy at 23 +/- 5Deg.C (73 +/- 9Deg.F), <75% R.H.
Battery: 1.5V x 3pcs AAA size, included
Battery Life: 300 hours, typical use
Temperature: Range: -100 to 850 Deg.C (-148 to 1562 Deg.F) type K (CHROMEGAR-ALOMEGA)
Resolution:
1 Deg.C or 1Deg.F, 0.1 Deg.C or 0.1 Deg.F
Accuracy (does not include probe):
18 to 28 Deg.C (64 to 82 Deg.F) ambient
+/-(0.3% rdg + 1 Deg.C) on Deg.C ranges
+/-(0.3% rdg + 2 Deg.F) on Deg.F ranges
Resolution: 0.1 Deg.C Range: -59.9 to 199.9°C
Resolution: 1 Deg.C Range: -100 to -60°C, 200 to 850°C
Resolution: 0.1 Deg.F Range:-59.9 to 199.9 Deg.F
Resolution: 1 Deg.F Range:-148 to -60 Deg.F, 200 to 1562 Deg.F
PDF et manuels
Afficher les notes et les avis
Rated 5 out of
5
by
Cesar Ojeda L from
Excellent measuring equipment
Temperature and Humidity measurement equipment with NIST Certificate, very good precision
Date published: 2023-09-11
Rated 5 out of
5
by
LabDirector from
It's accurate with the NIST certificate
NIST certificate included with purchase, So glad it works
Date published: 2022-08-08
Rated 5 out of
5
by
Anonymous from
Thermometers in undergrad lab.
We use these thermometers in an undergraduate engineering lab, and they stand up well to the wear & tear that's typical of busy students. A fine replacement for the old mercury thermometers!
Date published: 2020-11-11
Rated 5 out of
5
by
Professional engineer from
Simple, cost competitive, robust thermometer
Needed a self-powered, K type thermometer for on-vehicle, visual-reading. Could get wet, high vibration possible but must have a good battery life. This is my second as the first failed after many years service. Was very happy with the product so I just purchased another.
Date published: 2020-07-15
Rated 4 out of
5
by
jerry fletcher from
works good for what i do.
I bought (4) units with handle probes and did not receive the magnet hangers
Date published: 2018-11-01
Rated 5 out of
5
by
Jeremy from
Very Reliable
We have used these for the past 6 years and they work great. We monitor temperature of our flash tester with this. No more broken glass thermometers.
Date published: 2018-03-06
Rated 5 out of
5
by
DonB1243 from
Works Great
This thermocouple works great. The magnet mount is convenient.
Date published: 2017-03-30
What sensor can I use with this to measure down to -100C?
Thank you for your question.
5sc-tt-k-30-36 is a wire thermocouple that will be able to give you a reading at -100C
Date published: 2020-05-10
Does this include a K type thermocouple? Or does it need to be purchased separately?
Thank you for your inquiry. This device comes with a 36" Type K Thermocouple.
Date published: 2020-06-09
Is the sensor fully waterproof?
Hi Cash,
The HH74K does not ship with a thermocouple. If you require a thermocouple that is fully submersible you can look at part number HSTC-TT-K-24S-36.
Date published: 2019-10-08