L'aperçu du produit
- Battery life 100 hr
- Height 150 mm
- Length 30 mm
- Measuring Temperature Range, Max 300 °C
- Measuring Temperature Range, Min -100 °C
- Number of Channels 1
- Operating Temperature Note Operating Temperature/Humidity:0 to 50°C (32 to 122°F); 0 to 80% RH
- Power Consumption 0.53 mA
- Probe Dimensions Note Approx 120 mm (4.72")
- Probe Length 120 mm
- Relative Humidity, Max 0.8
- Relative Humidity, Min 0%
- Sampling Rate 2 Hz (2 updates/second)
- Sheath Length 100 mm
- Sheath Material 304 Stainless Steel
- Storage Temperature, Max 60 °C
- Storage Temperature, Min -10 °C
- Storage Temperature Note Storage Temperature and Humidity:-10 to 60°C (14 to 140°F); 0 to 80% RH
- Supply Power Note Maximum Voltage at Temperature Input: 60 Vdc or 24 Vrms AC
- Supply Voltage 60 Vdc
- Temperature Accuracy ± 0.1% of rdg + 0.4 °C
- Temperature Accuracy Note Accuracy (at 23 ± 5°C): ± 0.1% of rdg + 0.4°C (± 0.1% of rdg + 0.8°F) Probe Accuracy : IEC751, Class A ± 0.15°C ± 0.002t (t = measurement temperature)
- Temperature Coefficient For ambient temperatures from 0 to 18°C and 28 to 50°C, add 0.01% of rdg + 0.03°C or 0.01% of rdg + 0.06°F
- Temperature Resolution 0.1 °C
- Temperature Sensor Type RTD
- Weight 175 g
- Weight Note 175 g (6.2 oz)
- Width 66 mm
The HH370 Pt100 & Pt1000 Digital Thermometer is a waterproof, highly accurate handheld RTD temperature meter that uses the dedicated probes RTD-370-PT100 and RTD-370-PT1K. These probes have a water-resistant connection and a measurement range of -100 to 300°C (-148 to 572°F). The 100 Ω probe is included with the unit.
SPECIFICATIONS
Accuracy (at 23 ± 5°C): ± 0.1% of rdg + 0.4°C (± 0.1% of rdg + 0.8°F)
Temperature Coefficient: For ambient temperatures from 0 to 18°C and 28 to 50°C, add 0.01% of rdg + 0.03°C or 0.01% of rdg + 0.06°F
Probe Accuracy: IEC751, Class A ± 0.15°C ± 0.002t (t = measurement temperature)
Resolution: 0.1°C (0.1°F)
Measurement Range: -100 to 300°C (-148 to 572°F)
Numerical Display: 4-digit LCD
Input Type: Pt100 and Pt1K RTD, alpha = 0.003850, 4-wire
Measurement Current: Approx. 0.53 mA
Maximum Voltage at Temperature Input: 60 Vdc or 24 Vrms AC
Environmental:
Operating Temperature/Humidity: 0 to 50°C (32 to 122°F); 0 to 80% RH
Storage Temperature and Humidity: -10 to 60°C (14 to 140°F); 0 to 80% RH
Sample Rate: 2 times per second
Battery Life: 100 hours with alkaline batteries
Battery Type: 3 'AAA' (included)
Weight: 175 g (6.2 oz)
Dimensions: 150 H x 66 W x 31 mm D (5.9 x 2.6 x 1.2')
Connection: Water-resistant 5-pin connector
Overall Temperature Probe Length: Approx. 120 mm (4.72') 304 SS Length: 100 mm (3.94')
Sensor Cable Length: 1500 mm (59.06')
Sensor Diameter: Approximately 3.2 mm (0.125')
PDF et manuels
Afficher les notes et les avis
Rated 5 out of
5
by
Timcat from
Stable, accurate and surprise extra
This unit has excellent accuracy specs and works perfect for the narrow temperature range I need it for. Not mentioned on the website description was a built in function to memorize a reference temp and monitor the change in temperature. This is perfect for my application and I’m very pleased with the unit.
Date published: 2018-01-17
Rated 5 out of
5
by
KenZ from
The HH370 is just what I needed
I bought this temperature meter about a month ago. I needed to insure that a low cost digital thermometer was measuring correctly. The HH370 allowed me to quickly and easily confirm the temperature measurements. I plan to use the HH370 as a temperature standard which will allow me to adjust other low cost temperature controllers and meters to insure that they are measuring accurately.
I did purchase the small carrying bag along with the meter. I was disappointed with the bag due to the fact that the probe will not fit in the bag. The probe is too long. This tends to render the bag useless since I prefer to keep the meter and the probe together as one unit.
Date published: 2017-11-01
Can I order the HH370 RTD Thermometer with its probe calibrated at two points 0 & 100 C with NIST cert included ?
Calibrating at customer specific temperatures needs to be priced by the Temperature Engineering group. You can send your request to temp@omega.com and someone will assist you.
Date published: 2021-06-04
What is the probe material of construction of the contacting surface?
The probe section that houses the temperature sensing element is made from 304 Stainless Steel.
Date published: 2022-07-20
Can RTD Pt100 &amp handheld measure when extend the Rtd PT100 with cable to 100m far away? Is it suitable with an explosion proof ExiaI?
The meter and probe are an integral system for this meter and there are no extension cables offered. In general it would not be recommended to run long lengths of RTD cable as the wire would add additional Resistance affecting the accuracy of the measurement.
Date published: 2020-06-25