Skip to search Skip to main content Skip to navigation

Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

AHP-7561

316 SS Inline Duct Heater up to 1000°F and .75 kW Power

C$317.63

Article# AHP-7561

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$317.63
5-9 C$301.75
10-24 C$295.40
25-49 C$282.69
50-99 C$276.34
100+ C$269.99

En stock

Délai de livraison (si pas en stock): 9 semaines

Spécifications du produit

<< Voir toutes les modèles de produits
Brand
Air Flow, Max 20 CFM
Diameter 0.75 in
Heater Length 5.5 in
Heater Power 750 W
Inlet Air Temperature, Max 121 °C
Lead Length 0.3 m
Lead Material Fiberglass
Length 6 in
Mounting Inline
Operating Pressure, Max 80 psi
Outlet Air Temperature, Max 540 °C
Power Density, Max 136 W/in²
Power Tolerance +5, -10%
Process Connection Size 3/4 in
Process Connection Type NPT Male
Sheath Material Stainless Steel
Supply Voltage 120 Vac
Weight 308 g
Voir toutes Spécs Montrer moins
316 SS Inline Duct Heater up to 1000°F and .75 kW Power AHP-7561 AHP-7561
Rated 5 out of 5 by from High Efficiency and great design I've bought several of these because for heating any type of non-reactive gas there really is no substitute or better product available. These have convenient NPT threads on each end (which can be complicated if you want to go to high temperatures which would melt PTFE tape) and are relatively open to allow high flow rate gas streams to pass through. Highly recommended. One tip, don't heat them when there is no flow through them. They tend to burn out easily if you aren't providing cooling power.
Date published: 2016-02-05
Rated 5 out of 5 by from Simple to use and install I purchased one of these for a project a month ago. It was for a piece of test equipment that will require at least three units in parallel. This first unit worked exactly as I expected.
Date published: 2017-11-18
Rated 5 out of 5 by from Nicely built Works as expected. Nicely built. The warehouseman operating the forklift was bringing me the package and accidently dropped it while passing it to me and ran it over. It has a slight bend in the tube, but still works great!
Date published: 2024-11-26
Rated 5 out of 5 by from On time every time Excellent product and outstanding customer service
Date published: 2024-04-12
Rated 5 out of 5 by from Shipped quickly, and just what we needed! Great Product, Shipped quickly, and just what we needed!
Date published: 2023-12-07
Rated 5 out of 5 by from Works as advertised Bought this line heater to heat nitrogen when purging refrigerant systems on aircraft. At 200w I had to use a snubber to slow the flow, but it heats sufficiently for what it is
Date published: 2022-03-12
Rated 5 out of 5 by from Works as expected Works reliably for our process with good heat output
Date published: 2021-05-17
Rated 5 out of 5 by from Well-made heating tube Really nice air heater tube that is very adjustable via voltage input. Very well made. Will use this at lower voltage to heat air going into a microscope environmental chamber. Not what they made it for, but because adjusting voltage works so well, it works fine for me for this purpose.
Date published: 2021-03-01
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_9
  • loc_en_CA, sid_AHP-7561, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
fr-CA
fr
Enregistrer la configuration