Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici
HH501DK
4-Channel Type-K Thermometer with Backlit Display

Choisissez une variante
Display Type
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-4 | C$253.12 |
5-9 | C$240.46 |
10-24 | C$235.40 |
25-49 | C$225.28 |
50-99 | C$220.21 |
100+ | C$215.15 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
Spécifications du produit
<< Voir toutes les modèles de produitsBrand |
![]() |
Additional Features 1 | Read HOLD,MAX Function |
Battery Indication | “+ -” is displayed when battery voltage drops below operating level |
Diameter | 53 mm |
Display Type | 3.5 Digit LCD |
Display Type Note | 3 1⁄2 digit liquid crystal display (LCD) with maximum reading of 1999 Default Display Output : Zero : Automatic |
Electrical Connection | Sub-D Male Miniature Connector |
Height | 195 mm |
Measuring Temperature Range, Max | 1300 °C |
Measuring Temperature Range, Min | -50 °C |
Number of Channels | 4 |
Operating Temperature Note | 0 to 50°C (32 to 122°F)@ <70% RH |
Operating Temperature, Max | 50 °C |
Operating Temperature, Min | 0 °C |
Overrange | (OL) or (-OL) is displayed |
Polarity | Automatic, positive implied, negative polarity indication |
Relative Humidity, Max | 0.8 |
Relative Humidity, Min | 0% |
Sampling Rate | 2.5 Hz (2.5 updates/second) |
Storage Temperature Note | -20 to 60°C (-4 to140°F), 0 to 80% RH with battery removed from meter |
Storage Temperature, Max | 60 °C |
Storage Temperature, Min | -20 °C |
Supply Voltage | 9 Vdc |
Temperature Accuracy | ± 0.3% |
Temperature Accuracy Note | ± (0.3% rdg + 1°C) -50 to 1000°C; ± (0.5% rdg + 1°C) 1000 to 1300°C; ± (0.3% rdg + 2°F) -58 to 1999°F Stated accuracy : 23°C ± 5°C <75% relative humidity (accuracy specification does not include |
Temperature Resolution | 0.1 °C |
Temperature Sensor Type | Thermocouple |
Thermocouple Type | K |
Weight | 250 g |
Weight Note | Approximately 250 g (9 oz) including battery |
Width | 92 mm |
Voir toutes Spécs |
PDF et manuels
Afficher les notes et les avis
Rated 5 out of
5
by
Jim Hightower from
Design problem
I used a shorting bar to check the four inputs to see if they were the same. They indicated the ambient temperature but, when the supplied thermocouples were plugged in, a different ambient temperature was indicated. I assume that this is due to the tolerance of the thermocouple wire. A bigger difficulty was the spacing of the TC receptacles. When all four TCs are plugged in, it is very difficult to remove one of the plugs. It was necessary for me to pry two of them out with a small screwdriver before the other two could be removed. This is a design problem that should never been approved for manufacture.
Date published: 2020-11-23