OS768-LS-Series
-64 °C to 1800 °C Dual Laser Infrared Thermocouple Thermometer
Modèles en stock
- Wide Measurement Range: Infrared Up to 1800°C (3272°F)
- Dual Laser Points for the Target Spot Size
- Hi/Lo Temperature Audible Alarm
- Memory Mode Records and Displays the Specific Temperature with Emissivity
OS768-LS-Series
Depuis
C$
1,278.05
Modèles en stock

L'aperçu du produit
- Accuracy ± 1 %
- Accuracy Detail ± 1% of reading or 1°C (1.8°F) whichever is greater (Test under T amb = 23± 6°C)
- Alarm High and Low
- Ancillary Temperature Probe -64 to 1400 °C, Bead: -50 to 250°C,Accuracy:± 1%, Resolution:0.1°C,Response Time: 1 second
- Applications Aeronautics and Aerospace, Building and Maintenance, Industrial and Manufacturing, Laboratories and Scientific
- Battery life up to 180 hr
- Battery Size and Type Alkaline AA
- Display Monitoring Function Average, Differential, Hi Alarm, Lo Alarm, Lock, Max, Min, Real-time
- Display Note Color Backlit LCD
- Display Type LCD
- Emissivity, Max 0.95
- Emissivity, Min 0.95
- Emissivity Note 0.95 default – adjustable 0.1 to 1 step .01
- Field of view 75:1
- Form factor Pistol Grip
- Height 204.14 mm
- Laser Dual Laser
- Length 179.19 mm
- Memory Detailed 24 memories with temperature and emissivity
- Process Temperature, Min 0 °C
- Resolution 0.1°C
- Resolution Note 0.1°C/0.1°F at -83.2 to 999.9 (°C/°F), otherwise 1°C/1°F
- Response Time 1 sec
- Temperature Sensor Type Thermocouple Type K
- Weight 355 g
- Weight Note 355 grams (12.52 oz) including batteries (2 “AAA” batteries included)
- Width 58.4 mm
Description
OMEGA’s OS768-LS is theultimate tool for temperaturemeasurement. Accurately verifysurface temperatures with twoof the most reliable temperaturesensors:• Non-contact micro-machinedthermopile
• Type K thermocouple input(free T/C included)
Such an arrangement can fulfillmost temperature measurementrequirements. The non-contactinfrared measurement is ideal fornon-reachable situations, due tosafety or sanitary reasons—instantreadings, safely and reliably.Or use the thermocouple for highprecision measurement of contactsurfaces, gases, and liquids.The OS768-LS can also helpmeasure emissivity, which is oftendifficult for a user to determine.Use the Type K thermocouplecontact to measure the truetemperature. Then, use the non-contactinfrared to get the surfacetemperature. Adjust the emissivityuntil they are the same, with theoption to use the same emissivitysetting for that object next time.No more guess work, no morelooking up on Emissivity Table.This unit also comes with anultra-long battery life (batteries are included).