OM-USB-TEMP-AI
Eight Channel Temperature/Voltage Input USB Data Acquisition Modules

Choisissez une variante
Number of Channels, Input
Output Signal
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-4 | C$1,350.74 |
5-9 | C$1,283.20 |
10-24 | C$1,256.19 |
25-49 | C$1,202.16 |
50-99 | C$1,175.14 |
100+ | C$1,148.13 |
Spécifications du produit
<< Voir toutes les modèles de produitsBrand |
![]() |
A/D Conversion | Dual 24-bit sigma delta A/D converters |
Accuracy | ± 0.25 °C |
Analog I/O Note | Analog Input Note: A/D Converter;OM-USB-TEMP-AI: Dual 24-bit sigma-delta A/D converters ;Input Isolation: 500 Vdc minimum between field wiring and USB interface;Number of Channels;OM-USB-TEMP-AI: 4 differential temperature inputs and 4 differential or single-ended voltage inputs;Thermocouple Input: Software programmable for type J, K, T, E, R, S, B, N;Pt100 RTD Input: 2, 3 or 4-wire DIN 43760, a = 0.00385, SAMA, a = 0.003911, ITS-90/IEC751, a = 0.0038505;Thermistor Input: 2, 3 or 4-wire standard 2252 through 30,000 Ω;Semiconductor Sensor: TMP36 or equivalent;Maximum Input Voltage;Temperature inputs; ±25V (power on), ±40V (power off): voltage inputs; ±25V (power on), ±15V (power off);Throughput Rate: 2 samples/sec max for all active channels;Input Impedance: Temperature inputs; 5 GΩ(power on), 1 MΩ (power off): voltage inputs; 10 GΩ(power on), 2.49 KΩ(power off);Input Leakage Current;Thermocouples inputs; 105 nA maximum (with open thermocouple detection enabled), 30 nA maximum (with open thermocouple detection disabled): voltage inputs; ±1.5 nA typ, ±25 nA max;Maximum Working ;Voltage (OM-USB-TEMP-AI Voltage Inputs): ±10.25V max (input signal + common mode);Common Mode Rejection Ratio: Temperature inputs, 100 dB minimum; voltage inputs, 83 dB minimum;Warm-Up Time: 30 minutes maximum ;Open Thermocouple Detection: Automatically enabled when a channel is configured for a thermocouple sensor;CJC Sensor Accuracy: ±0.25°C typical, ±0.5°C max (15 to 35°C); -1.0 to 0.75°C max (0 to 70°C) |
CMRR | Thermocouple inputs, 100 dB min; Voltage mode, 83 dB min |
Configuration Parameters | Pull-Up/Down Configuration, User-Configurable Input/Output |
Data Interface | Ethernet, USB 1.1, USB 2.0 |
Data Interface Note | Configuration Method: TracerDAQ Software;Supported Operating System: Microsoft Windows® VISTA/7/8/10 (32-bit and 64-bit) |
Digital I/O Note | DIGITAL I/O Number of Digital I/O Channels: 8 Type: CMOS Configuration: Each DIO bit can be independently configured for input or output; power on reset is input mode Pull-Up/Pull-Down Configuration:All pins pulled up to 5V via 47 kΩresistors (default). Pull-down to ground (GND) also availableDigital I/O Transfer Rate (Software Paced):Digital Input: 50 port reads or single bit reads per second (typical) Digital Output: 100 port writes or single bit writes per second (typical) Input High Voltage: 2.0V min, 5.5V absolute max Input Low Voltage: 0.8V min, -0.5V absolute min Output High Voltage: 0.7V max (IOL = 2.5 mA) Output Low Voltage: 3.8V min (IOH = -2.5 mA);Transfer Rate: Digital: Input: 50 port reads or single bit reads per second (typical), Output: 100 port writes or single bit writes per second (typical) Counter Read/Write Rates (Software Paced, System Dependent): 33 to 1000 read/writes per second;Pulse Width: Counter: High Pulse Width: 500 ns minimum, Low Pulse Width: 500 ns minimum;Schmitt Trigger Hysteresis: Counter: 20 mV to 100 mV |
Digital Input | Digital: Low = –0.5 to 0.8 Vdc |
Digital Output | <100 mA typical |
Electrical Connection | Screw Terminal |
Frequency Input Range | 1 MHz |
Height | 36 mm |
Impedance Input | Thermocouple inputs; 5 GΩ (power on), 1 MΩ (power off): voltage inputs; 10 GΩ (power on), 2.49 kΩ (power off) |
Input Configuration | Connected Software |
Input Type | Thermocouple, RTD, Thermistor, Diode, Digital |
Input Type Note | Thermocouple: J, K, T, E, R, S, B, N, RTD: pt100, 2, 3 or 4-wire DIN 43760, a = 0.00385, SAMA, a = 0.003911, ITS-90/IEC751, a = 0.0038505, Thermistor: 2, 3 or 4-wire standard 2252 through 30,000 Ω, Semiconductor Sensor: TMP36 or equivalent |
Input Voltage Note | Absolute Maximum Input Voltage: Thermocouple Inputs; ±25V (Power On), ±40V (Power Off): Voltage Inputs; ±25V (Power On), ±15V (Power Off) |
Isolation | Power Isolation: 500 Vdc minimum measurement system to PC, Input Isolation: 500 Vdc min between field wiring and USB interface |
Leakage Current | 105 nA |
Length | 127 mm |
Number of Channels, Input | Temperature: 4 DIFF, Voltage: 4 DIFF or Single-ended, Digital: 8, Counter: 1 |
Number of Channels, Output | Digital: 8 |
Operating Temperature, Max | 50 °C |
Operating Temperature, Min | 0 °C |
Output Signal | Digital |
Pull-down Resistor | 47 kΩ |
Pull-up Resistor | 47 kΩ |
Relative Humidity | 0 to 90% RH non-condensing |
Sampling Rate | 2 Hz (2 updates/second) |
Storage Temperature, Max | 85 °C |
Storage Temperature, Min | -40 °C |
Supply Power Note | Power Supply Voltage (Supplied by USB Port): 4.75V min to 5.25V maximum, Power Supply Current (Supplied by USB Port): <100 mA typical (USB enumeration); 270 mA typical for continuous input with all inputs configured for disabled mode (500 mA for OM-USB-5201) User 5V Output Voltage Range (connected to self-powered hub): 4.9 V minimumto 5.1 V maximum User 5V Output Current (bus powered and connected to self-powered hub): 5 mA maximum |
Supply Voltage | 5 Vdc |
USB Cable Length | 3 m |
Warm Up Time | 30 min |
Weight | 182 g |
Width | 89 mm |
Wire Gauge | 30 to 16 AWG |
Voir toutes Spécs |
PDF et manuels
Logiciels et pilotes
Afficher les notes et les avis
Rated 5 out of
5
by
Javier Canete from
Good Experience
I bougth some product since a lot of year and the quality and experience are very good.
Date published: 2018-06-27
Rated 5 out of
5
by
Michael T from
Extremely Easy to Use
Easy to use. Just wired up my thermistors and downloaded TracerDAQ and everything was super easy to set up. Would recommend
Date published: 2022-01-04