PX409S15-32BI

0 to 32 inHg, Barometric, 4 to 20 mA, 1.5" Tri-Clamp, Cable

C$1 853.17

Article# PX409S15-32BI

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-9 C$1 853.17
10-24 C$1 760.51
25-49 C$1 723.45
50-99 C$1 649.32
100+ C$1 612.26

En stock

Délai de livraison (si pas en stock): 17 semaines

Spécifications du produit

<< Voir toutes les modèles de produits
Brand
ADC Resolution None
Accuracy ± 0.08 %
Accuracy Class < 0.1%
Accuracy Note ± 0.08% best straight line (linearity, hysteresis and repeatability combined) compound gage models calibrated in positive direction only
Additional Features 1 None
Bandwidth DC to 1 kHz
Burst Pressure 4x Full Scale to Maximum Rated Flange Pressure
Compensated Temperature, Max 87.7 °C
Compensated Temperature, Min -1.1 °C
Electrical Connection Cable
Electrical Output 4 to 20 mA
Enclosure Ratings IP65, IP67
Fill Fluid NEOBEE M5 food grade
Insulation Resistance 100 MΩ @ 50 Vdc
Loop Resistance, Max (Vs-9) x 50 Ω
Materials, Wetted 316L Stainless Steel
Operating Temperature, Max 115 °C
Operating Temperature, Min -15 °C
Output Signal Current
Pressure Cycles 1 million
Pressure Type Barometric
Pressure, Max 32 inHg
Pressure, Min 0 inHg
Process Connection Note 1 1⁄2" and 2" Tri-GripTM (Tri-Clamp® compatible) Fitting: 600 bar using suitable clamp
Process Connection Size 1 1/2 in
Process Connection Type Tri-Clamp
Proof Pressure 6x Full Scale up to 2000 psi
Response Time <1 ms
Shock 50 g, 11 ms half sine (under test)
Shunt Calibration Value 5-point NIST traceable calibration with zero and span values, calibrated in horizontal direction
Span Setting Adjustable Range ± 0.5% FS
Stability ± 0.1%
Supply Power Note 9 to 30 Vdc [9 to 20 Vdc above 105°C (229°F)]
Supply Voltage 9 to 30 Vdc
Thermal Effect on Span error, Max 0.01%/°F
Thermal Effect on Zero error, Max 0.01%/°F
Vibration ± 20 g
Weight 285 g
Zero/Balance Error ± 0.5%
Zero/Balance Error Note ± 0.5% FS typical ± 1% max (for ranges ≤ 5 psi ± 1% typ. ± 2% max)
Voir toutes Spécs Montrer moins
0 to 32 inHg, Barometric, 4 to 20 mA, 1.5" Tri-Clamp, Cable PX409S15-32BI PX409S15-32BI
Rated 5 out of 5 by from Helped me with HW assignment Was a great help in my aerospace course !!!!!!!!!!!
Date published: 2021-09-09
Rated 5 out of 5 by from Accurate and durable Great product very accurate and durable. However it is not a wise idea to press on the diaphragm. When our company first started using these the boss thought it would be a good idea for testing, the Sensor was damaged beyond repair immediately
Date published: 2020-07-28
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_CA, sid_PX409S15-32BI, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
fr-CA
fr
Enregistrer la configuration