Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici
DW-G-NZ-F-S-AK-WW-XX-G-F
Wall Mount Ultrasonic Flow w/IP67 Clamp-On Transducers, 30' Cable

Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
Spécifications du produit
<< Voir toutes les modèles de produitsAccuracy | ± 1 % |
Cable Length | 50 ft |
Calibration Option | Factory Calibrated |
Certifications | CE |
Data Interface | BACnet MS/TP, Modbus RTU, USB |
Display Language | English, French, German and Spanish selectable |
Display Note | Keypad: 4-button navigation, membrane keypad with domed tactile feedback Resolution: 128 × 64 pixel LED backlit graphical display; adjustable brightness and timeout |
Display Type | LED |
Electrical Output | 4 to 20 mA, Two Pulse, Frequency |
Enclosure Ratings | IP65 |
Form factor | Pipe Remote mount |
Keypad | Yes |
Materials | 316 Stainless Steel, Polycarbonate |
Measurement Type | Transit Time |
Number of Outputs | 4 |
Operating Temperature, Max | 60 °C |
Operating Temperature, Min | -20 °C |
Output Detail | Pulse / Frequency /Digital : Two outputs, each selectable as frequency, pulse, forward/reverse flow or alarm output; isolated open collector, 5-30V DC, 50 mA maximum, externally or internally sourced with pullup resistor Digital alarm output: configurable high or low Frequency output: 63 Hz-10 kHz maximum Pulse (totalizer) output: 100 Hz maximum output open collector, pulse width 5-500 ms programmable Analog Output: 0-20 mA and 4-20 mA drive up to 800 Ohms; minimum 16-bit resolution, isolated Open Collector Output: 5 to 30 Vdc, max. 50 mA externally or internally sourced |
Pipe Size, Max | 10 in |
Pipe Size, Min | 2.5 in |
Process Temperature, Max | 90 °C |
Process Temperature, Min | -40 °C |
Pulse Rates | 100 Hz |
Repeatability | ±0.2% |
Repeatability Note | ±0.2% of reading |
Reserved Type | Standard |
Software | SoloCUE |
Storage Temperature, Max | 80 °C |
Storage Temperature, Min | -40 °C |
Supply Power Type | DC |
Supply Voltage | 9 to 28 Vdc |
Transducer Type | DTTN |
Velocity, Max | 40 ft/s |
Velocity, Min | 0.1 ft/s |
Voir toutes Spécs |
PDF et manuels
Logiciels et pilotes
Afficher les notes et les avis
Rated 5 out of
5
by
Vitalic from
Very slow customer service
Very slow customer support. Device has power and display backlight is on but no digits. Customer support tells me to check transformer fuses and power, doesn't understand device has power. Was able to connect with a USB cable and programmed it so there's a reading until I hear back from warranty department, which is not faster than customer service. It's been a few days and still waiting for anyone to follow up with me.
Date published: 2023-10-02