DQ-G-LZ-B-S-AC-AC-S-XX-S-G-F
Flow Meter w/Large Pipe Clamp on Transducers (LZ), DC Power, 15' Cable

Choisissez une variante
Transducer Type
Supply Voltage
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
Spécifications du produit
<< Voir toutes les modèles de produitsAccuracy | ± 1 % |
Cable Length | 15 ft |
Calibration Option | Factory Calibrated |
Certifications | CE |
Data Interface | BACnet MS/TP, Modbus RTU, USB |
Display Language | English |
Display Note | Keypad : 4-button navigation, keypad with tactile feedback; polyester film Display128 × 64 pixel LED backlit graphical display; adjustable brightness and timeout; polycarbonate window |
Display Type | LED |
Electrical Connection | 1/2 in NPT female Conduit with Poly Cable Glands |
Electrical Output | 4 to 20 mA, Two Pulse, Frequency |
Enclosure Ratings | IP67, NEMA 4 |
Form factor | Pipe Remote mount |
Keypad | Yes |
Materials | PVC, CPVC, HDPE, PTFE, PDVF, Stainless Steel, Ductile Iron, Aluminum, Brass, Carbon Steel, Copper |
Measurement Type | Transit Time |
Number of Digits | 8 |
Number of Outputs | 4 |
Operating Temperature, Max | 60 °C |
Operating Temperature, Min | -20 °C |
Output Detail | 4-20 mA output:One 16-bit, isolated, max 800 Ohms, internal or external power Digital output:Two selectable pulse, alarm, flow direction, sink isolated open collector, 5-30V DC, max. 50 mA externally or internally sourced Frequency output: 50% duty cycle, 63-10k Hz maximum frequency Pulse (totalizer) output: 5 kHz max. output, open collector, pulse width 5-500 ms programmable Optional: Two dry contact output for alarm or flow direction 30V DC max., 5A max. (Ethernet not available with this option); Open Collector Output: 5 to 30 Vdc, max. 50 mA externally or internally sourced |
Pipe Size, Max | 48 in |
Pipe Size, Min | 8 in |
Process Temperature, Max | 90 °C |
Process Temperature, Min | -40 °C |
Pulse Rates | 5 KHz |
Relative Humidity | 85% non condensing |
Repeatability | 0.002 |
Repeatability Note | 0.2% above 1.5 ft/s |
Software | SoloCUE |
Storage Temperature, Max | 80 °C |
Storage Temperature, Min | -40 °C |
Supply Power Type | DC |
Supply Voltage | 9 to 28 Vdc |
Transducer Type | Large pipe |
Velocity, Max | 40 ft/s |
Velocity, Min | 0.1 ft/s |
Volumetric Flow Rate, Max | 33000 GPM |
Volumetric Flow Rate, Min | 0 GPM |
Voir toutes Spécs |