Modèles en stock
  • Standard Element Sheath Materials
  • Incoloy® 800 — A Nickel (30 to 35%), Chromium (19 to 23%), Iron alloy. The high nickel content of this alloy contributes to its resistance to scaling and corrosion. Used in air heating (also see Incoloy® 840) and immersion heating of potable water and other liquids that are not corrosive to an Incoloy® 800 sheath.
  • Low Carbon Steel — Applications include fluid heat transfer media, tar, high to low viscosity petroleum oils, asphalt, wax, molten salt, and other solutions not corrosive to a steel sheath.
  • 316 Stainless Steel — A Chromium (16 to 18%), Nickel (11 to 14%), Iron Alloy with Molybdenum (2 to 3%) added to improve corrosion resistance in certain environments, especially those that would tend to cause pitting due to the presence of chlorides. Applications include deionized water.
CHF7
Depuis C$ 1,666.32
Modèles en stock
Clean Water Circulation Heater CHF7 CHF7
loading all models
L'aperçu du produit
Surface Treatments for Stainless Steel and Incoloy® Elements and Other Wetted Parts to Improve Corrosion Resistance Flanged immersion heater surfaces in contact with the material being heated can be passivated or electro-polished to improve their resistance to corrosion. Passivation removes surface contamination, usually iron, so that the optimum corrosion resistance of the stainless steel is maintained. Surface contamination would come from the small amount of steel that may be worn off a tool during the manufacturing process. Passivating is accomplished by dipping the heater in a warm solution of nitric acid. Electro-Polishing is an electrochemical process that removes surface imperfections and contaminants, enhancing the corrosion resisting ability of the stainless steels. The resultant surface is clean, smooth and bright. Many medical and food applications require this finish.

8 watts/in2 (1.3 watts/cm2) — Typical Applications: Fuel Oils (Bunker C and Number 6)
Nominal Pipe Size Dimensional Drawing Number KW Model Number Approx Weight
120V 240V-1Ph (C*) 240V-3Ph (C*) 480V-1Ph (C*) 480V-3Ph (C*) lb kg
21⁄2 NPT 3 elements 2.2 2 — — CHF01100(1) — CHF01101(1) 37 17
2.3 3 — — CHF01102(1) — CHF01101(1) 46 21
3"—150 lb 3 elements 3.2 2 — — CHF01104(1) — CHF01105(1) 62 28
3.3 3 — — CHF01106(1) — CHF01107(1) 76 34
(C*) = Number of Branch Circuits per heater
60 watts/in2 (9.3 watts/cm2)—Typical Applications: Clean Water
Nominal Pipe Size Model Number Dim Drawing Number KW Approx Weight
120V 240V-1Ph (C*) 240V-3Ph (C*) 480V-1Ph (C*) 480V-3Ph (C*) lb kg
11⁄4 NPT 2 elements CHF01859 CHF01860(1) — — — 1.1 3 14 6
— CHF01861(1) — — — 1.1 4 14 6
— CHF01862(1) — — — 1.2 5 17 8
— CHF01863(1) — — — 1.2 6 18 8
21⁄2 NPT 3 elements — CHF01864(1) CHF01865(1) CHF01866(1) CHF01867(1) 2.1 6 26 12
— CHF01868(1) CHF01869(1) CHF01870(1) CHF01871(1) 2.1 7.5 26 12
— CHF01872(1) CHF01873(1) CHF01874(1) CHF01875(1) 2.1 9 27 12
— — CHF01877(1) CHF01878(1) CHF01879(1) 2.2 12 34 15
— — CHF01881(1) CHF01882(1) CHF01883(1) 2.2 15 35 16
— — CHF01885(1) CHF01886(1) CHF01887(1) 2.3 18 43 20
3"—150 lb 3 elements — CHF01888(1) CHF01889(1) CHF01890(1) CHF01891(1) 3.1 6 52 24
— CHF01892(1) CHF01893(1) CHF01894(1) CHF01895(1) 3.1 9 53 24
— — CHF01896(1) CHF01897(1) CHF01898(1) 3.2 12 61 28
— — CHF01899(1) CHF01900(1) CHF01901(1) 3.2 15 67 30
— — CHF01902(1) CHF01903(1) CHF01904(1) 3.3 18 74 34
4"—150 lb 6 elements — CHF01905(2) CHF01906(1) CHF01907(1) CHF01908(1) 4.1 12 77 35
— CHF01909(2) CHF01910(1) CHF01911(1) CHF01912(1) 4.1 18 79 36
— CHF01913(2) CHF01914(2) CHF01915(2) CHF01916(1) 4.2 24 92 42
— — CHF01917(2) CHF01918(2) CHF01919(1) 4.2 30 94 43
— — CHF01920(2) CHF01921(2) CHF01922(1) 4.3 36 117 53
— — — — CHF01923(2) 4.3 50 121 55
— — — — CHF01924(2) 4.4 60 145 66
5"—150 lb 6 elements — CHF01925(2) CHF01926(2) CHF01927(2) CHF01928(1) 5.1 24 115 52
— — CHF01929(2) CHF01930(2) CHF01931(1) 5.1 30 117 53
— — CHF01932(2) CHF01933(2) CHF01934(1) 5.2 36 128 58
— — — — CHF01935(2) 5.3 50 167 76
— — — — CHF01936(2) 5.4 60 196 89
5"—150 lb 9 elements — — CHF01937(3) CHF01938(3) CHF01939(3) 5.1 36 120 54
— — CHF01940(3) CHF01941(3) CHF01942(3) 5.1 45 122 55
— — CHF01943(3) CHF01944(3) CHF01945(3) 5.2 54 134 61
— — — — CHF01946(3) 5.3 75 176 80
— — — — CHF01947(3) 5.4 90 197 89
6"—150 lb 12 elements — CHF01948(2) CHF01949(2) CHF01950(2) CHF01951(1) 6.1 24 125 57
— CHF01952(3) CHF01953(2) CHF01954(2) CHF01955(1) 6.1 36 129 59
— — CHF01956(4) CHF01957(3) CHF01958(2) 6.2 48 153 69
— — CHF01959(4) CHF01960(3) CHF01961(2) 6.2 60 157 71
— — CHF01962(4) — CHF01963(2) 6.3 72 196 89
— — — — CHF01964(2) 6.3 100 204 93
— — — — CHF01965(4) 6.4 120 246 112
6"—150 lb 15 elements — CHF01966(3) CHF01967(5) CHF01968(3) CHF01969(1) 6.1 30 128 58
— CHF01970(5) CHF01971(5) CHF01972(3) CHF01973(5) 6.1 45 133 60
— — CHF01974(5) CHF01975(3) CHF01976(5) 6.2 60 158 72
— — CHF01977(5) CHF01978(5) CHF01979(5) 6.2 75 163 74
— — CHF01980(5) — CHF01981(5) 6.3 90 202 92
— — — — CHF01982(5) 6.3 125 213 97
— — — — CHF01983(5) 6.4 150 257 117
8"—150 lb 18 elements — — CHF01984(3) CHF01985(3) CHF01986(2) 8.1 50 210 95
— — CHF01987(6) — CHF01988(2) 8.2 75 238 108
— — CHF01989(6) — CHF01990(3) 8.3 100 266 121
— — CHF01991(6) — CHF01992(6) 8.4 125 294 133
— — — — CHF01993(6) 8.5 150 326 148
— — — — CHF01994(6) 8.6 175 358 162
— — — — CHF01995(6) 8.7 200 391 177
Ordering Example: CHF01865, 6 KW, 240 Vac, 3 phase circulation heater.
(C*) = Number of Branch Circuits per heater
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

What is the maximum working pressure for this heater (CHF01859)? would it be possible to use with water at 120 PSI?

Asked by: chrs
Please send your question to heaters@omega.com so an Applications Engineer can work with the Heater design group to see what the maximum pressure rating is on the Circulation Heater.
Answered by: ApplicationEngineerANB
Date published: 2022-11-10

What is the maximum GPM for this heater at a 20 degree delta? We need to heat our cooling water on injection molding machines so the barrel doesn't sweat. We have 55 degree cooling water with around 8 GPM on the supply piping to the machine.

Asked by: Brady
The calculation can be quite involved so please send your request to heaters@omega.com so all the specifics can be reviewed and the best recommendations can be made.
Answered by: ApplicationEngineerANB
Date published: 2022-07-07

What is the increase in temperature of air passing through this at 200 CFM at approximately 75 degree Fahrenheit?

Asked by: Brett
Hi Brett, The CHF01920 heater is for water applications. For air heating applications please see our GCHI series or search for p/n: GCHI-03-006P-E1/240 The formula to calculate power for heating air is SCFM x ΔT / 3 ΔT = temperature rise in deg F Best regards, OMEGA
Answered by: RD Engineer
Date published: 2020-04-07
  • y_2025, m_4, d_13, h_16CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_CA, sid_CHF01859, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 34ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration