Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

MT1-HEATER
Copper Immersion Heater 1.25 in NPT Clean Water
- 1¼" NPT Brass Screw Plug
- 120 V and 240V, 1 Phase
- General Purpose Models NEMA-1 Rated and UL Listed
- Copper Sheath, Ideal for Clean Water Applications
MT1-HEATER
Depuis
C$
347.16

L'aperçu du produit
- Heated Medium Water
- Heating Element Diameter 16 cm
- Number of Heating Elements 2
- Number of Phases 1
- Process Connection Material Brass
- Process Connection Size 1 1/4 in
- Process Connection Type NPT Male
- Sheath Diameter 0.315 in
- Sheath Material Copper
The MT-1 series immersion heater is ideally suited for clean water requirements. Models are available with a general purpose terminal enclosure1 or a rugged moisture resistant explosion resistant terminal enclosure.
Please Note: This immersion heater should be used with an approved temperature control device to assure safe operation. See Section P for our complete selection of process controllers.
CAUTION AND WARNING!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warning.
/* Designate voltage, insert 120 for 120 VAC or 240 for 240 VAC. Higher wattages available - contact OMEGALUX.
1. Heaters with General Purpose and Moisture Resistant Enclosures are UL Listed and CSA Certified.
2. Heaters with Explosion Resistant Enclosures are CSA NRTL/C certified and are not intended for use in hazardous areas.
Please Note: This immersion heater should be used with an approved temperature control device to assure safe operation. See Section P for our complete selection of process controllers.
CAUTION AND WARNING!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warning.
E1 General Purpose Encl.1 Model No. | E2 Explos. Res./ Moist Res Encl.2 Model No. | kW | Phase | W/in2 | No. Elem. | Dim. B in (cm) |
MT-160A/* | MT-160E2/* | 0.6 | 1 | 53 | 1 | 6 1/8 (16) |
MT-175A/* | MT-175E2/* | 0.75 | 1 | 65 | 1 | 6 1/8 (16) |
MT-110A/* | MT-110E2/* | 1 | 1 | 86 | 1 | 6 1/8 (16) |
MT-110-3A/* | MT-110-3E2/* | 1 | 1 | 43 | 2 | 6 1/8 (16) |
MT-112A/* | MT-112E2/* | 1.2 | 1 | 53 | 2 | 6 1/8 (16) |
MT-115A/* | MT-115E2/* | 1.5 | 1 | 65 | 2 | 6 1/8 (16) |
MT-120A/* | MT-120E2/* | 2 | 1 | 86 | 2 | 6 1/8 (16) |
1. Heaters with General Purpose and Moisture Resistant Enclosures are UL Listed and CSA Certified.
2. Heaters with Explosion Resistant Enclosures are CSA NRTL/C certified and are not intended for use in hazardous areas.