  • Operates Down to 1.2 K with Appropriate Sensors
  • 2 Sensor Inputs
  • Supports Diode, RTD, and Thermocouple Sensors
  • Sensor Excitation (Current Reversal Eliminates Thermal EMF Errors for Resistance Sensors)
CYC325-Series
Depuis C$ 4 800.00
Cryogenic Dual Channel Digital Benchtop Temperature Controller CYC325-Series CYC325-Series
loading all models
L'aperçu du produit
  • A/D Conversion 24-bit
  • Accuracy Selectable
  • Accuracy Note

    PTC RTD (0 to 500 Ω : Range) : ± 0.004 Ω, ± 0.01 % of rdg

    PTC RTD (0 to 5000 Ω : Range) : ± 0.004 Ω, ± 0.02 % of rdg

    NTC RTD (0 to 7500 Ω : Range) : ± 0.1 Ω, ± 0.04 % of rdg

    Thermocouple (± 25 mV) : ± 1 µV,± 0.05 % of rdg

    Thermocouple (± 50 mV) : ± 1 µV,± 0.05 % of rdg

  • Approvals CE Mark
  • Baud Rate 9600 to 57600
  • Control Characteristics

    PID Control Settings:

    • Proportional (Gain): 0 to 1000 with 0.1 setting resolution
    • Integral (Reset): 1 to 1000 (1000/s) with 0.1 setting resolution
    • Derivative (Rate): 1 to 200% with 1% resolution

    Manual Output: 0 to 100% with 0.01% setting resolution

    Zone Control: 10 temperature zones with P, I, D, manual heater out, and heater range

    Setpoint Ramping: 0.1 K/min to 100 K/min

    Safety Limits: Curve temperature, power up heater off, short circuit protection

  • Control Output Heater
  • Control Type Manual Heater Output, Open Loop, PID Control
  • Data Interface RS232
  • Digital Connector Type 9 pin Sub-D
  • Display Annunciators Autotune, Control input, Remote
  • Display Measuring Units °C, K, mV, V
  • Display Size 5.5 mm Digits
  • Display Type LCD
  • Display Type Note

    Display: 2-line, 20-character, liquid crystal display with 5.5 mm (0.216”) character height

    Display Update Rate: 2 rdg/s

    Other Displays: Setpoint, heater range, and heater output; user selected

  • Electrical Connection Ceramic Isothermal Block
  • Filter Averages 2 to 64 input readings
  • Form factor Benchtop
  • Front Panel Display Readings 1 to 4
  • Heater Output Display Percentage of full power or current
  • Heater Output Resolution 0.01
  • Height 89 mm
  • Input Type Thermocouple, RTD, Thermistor
  • Input Type Note Temperature, sensor units Input Configuration: Each input is factory configured for either diode/RTD or thermocouple
  • Interface Features IEEE-488 Interface Features: SH1, AH1, T5, L4, SR1, RL1, PP0, DC1, DT0, C0, E1
  • Isolation Sensor inputs optically isolated from other circuits but not each other
  • Keypad 20-key membrane, numeric and specific functions
  • Length 368 mm
  • Loops Control Loops : 2
  • Measurement Type Temperature
  • Number of Control Outputs 2
  • Number of Inputs 2
  • Operating Temperature, Max 35 °C
  • Operating Temperature, Min 15 °C
  • Output Detail 2 Heater output
  • Output Signal None
  • Power Consumption 6 W
  • Resolution Sensor dependent, refer to input specifications table
  • RTD Type 4-lead differential With 6-Pin DIN Connector
  • Sampling Rate 10 Hz (10 updates/second)
  • Sampling Rate Note To 10 rdg/s on each input
  • Sensor Input Configuration

    Measurement Type: 4-lead differential

    Excitation: Constant current with current reversal for RTDs Supported

    Sensors: Diodes, silicon, GaAlAs; RTDs, 100 Ω Platinum, 1000 Ω Platinum, germanium, carbon-glass, CernoxTM, and RoxTM Standard Curves: CY7 and CY670, PT-100, PT-1000, RX-102A, RX-202A

    Input Connector: 6-pin DIN

  • Sensor Units Display Resolution Sensor dependent up to 5 digits
  • Setpoint Setting Resolution Same as display resolution (actual resolution is sensor dependent)
  • Settable Parameters Curve Entry, Keypad Lock-out
  • Software Support LabVIEWTM driver; consult factory for availability
  • Supply Power Note Standard 120 Vac, optional 240 Vac, 6%, -10%, 50 or 60 Hz, 85 VA
  • Supply Power Type AC
  • Supply Voltage 100 to 240 Vac
  • Temp Display Resolution 0.001° from 0 to 99.999°, 0.01° from 100 to 999.99°, 0.1° above 1000°
  • Tuning Autotune, PID, PID zones
  • Update Rate, Max 10 rdg/s on each input (except 5 rdg/s on input A when configured as thermocouple)
  • Weight 4 kg
  • Width 216 mm

Description

The CY325 Series dual-channel temperature controlleris capable of supporting nearly any diode, RTD, orthermocouple temperature sensor. Two independentPID control loops with heater outputs of 25 and 2 Ware configured to drive either a 50 or 25 à™ load foroptimal control flexibility. Designed with ease of use,functionality, and value in mind, the CYC325-Series Series isideal for general-purpose laboratory and industrialtemperature measurement and control applications.
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
fr-CA
fr
Enregistrer la configuration