DP7800-Series
Dual Input Process Meters with Math Functions
- Dual Inputs with Programmable Math Functions
- Process Voltage or Current Inputs
- Programmable Ranges ± 200 mV to ± 200 V and 4-20 mA
- Digital Tare (Zero) up to 50% of Span
DP7800-Series
Depuis
C$
1 268.31

L'aperçu du produit
- Accuracy ± 0.01 %
- Accuracy Note ±0.01% of reading ±1 count of LSD
- Baud Rate 75 to 9600
- Common Mode Voltage 1400 Vp (AC or DC) between analog output ground and AC power line ground
- Control Output 2 SPDT Relay
- Conversion Rate 3/sec
- Cutout Dimensions 45 x 92 mm
- Display Size 14.3 mm (0.56 in)
- Display Type 5 Digit LCD
- Display Type Note 5-digit, 7-segment, 14.3 mm (0.56") high LED Limit
- Form factor 1/8 DIN
- Functions Range Programming: Solderless jumpers on rear of unit; select 200 mV, ±2V, ±20V, ±200V or 4 to 20 mA
- Height 50 mm
- Input Type MA, MV, 10V
- Number of Inputs 2
- Operating Temperature, Max 60 °C
- Operating Temperature, Min -20 °C
- Output Detail Standard dual form “A” relays rated 0.25 A @ 28V. Analog Output (Optional): 0 to 10 Vdc @ 2.5 mV resolution; 0V and 10V points are programmable via front-panel switches: maximum drive capability ±2 mA; the 4 mA and 20 mA points are programmable via front-panel switches; 4 to 20 mA output, maximum load 600 Ω
- Programmable Functions Range
- Relative Humidity 0 to 90% non-condensing
- Sampling Rate 3 Hz (3 updates/second)
- Storage Temperature, Max 85 °C
- Storage Temperature, Min -25 °C
- Supply Power Note Power: Standard: 115 Vac (15 to 10%) @ 50 mA (47 to 500 Hz) Optional: 230 Vac (15 to 10%) @ 25 mA (47 to 500 Hz) Optional: 9 to 18 Vdc or 18 to 36 Vdc
- Weight 454 g
- Width 97 mm
SPECIFICATIONS
Accuracy: ±0.01% of reading ±1 count of LSD
Range Programming: Solderless jumpers on rear of unit. Select 200 mV, ±2 V, ±20 V, ±200 V, and 4-20 mA
Conversion Rate: 3/second
Display: 5-digit, seven-segment LED 0.56" (14.3 mm) high
Limit Outputs: Standard dual form "A" relay rated 0.25 A at 28 V
Analog Output (optional): 0-10 Vdc @ 2.5 mV resolution. 0 V and 10 V points are programmable via front panel switches. Maximum drive capability ±2 mA The 4 mA and 20 mA points are programmable via front panel switches. 4-20 mA output, maximum load 600 Ohms
CMV: 1400 V Peak (ac or dc) between analog output ground and ac power line ground
Serial Interface (optional): ASCII RS-232 or RS-485 compatible; format 1 start bit, 8 data bits, 1 stop bit and no parity bits Baud Rates: 9600, 4800, 2400, 1200, 600, 300, 150 and 75 programmable from the front panel
Operating Temperature: -20 to 60°C (-4 to 140°F)
Storage Temperature: -25 to 85°C (-12 to 184°F)
Relative Humidity: 0% to 90%, Non-condensing
Power: 115 Vac (+15% -10%) @ 50 mA (47 to 500 Hz) Optional: 230 Vac (+15% -10%) @ 25 mA (47 to 500 Hz) Optional: 9-18 or 18-36 Vdc
Dimensions: 1.97 H x 3.80 W x 4.0" D (50 x 97 x 102 mm) (Rear Connectors add 0.5" to depth)
Panel Cutout: 1 /8 DIN 45 H x 92 mm W (1.77 H x 3.58" W)
Weight: 454 g (1 lb)
Examples of pricing for popular models is referenced in the "To Order" box. Use the "Part Number Builder" below to get pricing for all available models.
Accuracy: ±0.01% of reading ±1 count of LSD
Range Programming: Solderless jumpers on rear of unit. Select 200 mV, ±2 V, ±20 V, ±200 V, and 4-20 mA
Conversion Rate: 3/second
Display: 5-digit, seven-segment LED 0.56" (14.3 mm) high
Limit Outputs: Standard dual form "A" relay rated 0.25 A at 28 V
Analog Output (optional): 0-10 Vdc @ 2.5 mV resolution. 0 V and 10 V points are programmable via front panel switches. Maximum drive capability ±2 mA The 4 mA and 20 mA points are programmable via front panel switches. 4-20 mA output, maximum load 600 Ohms
CMV: 1400 V Peak (ac or dc) between analog output ground and ac power line ground
Serial Interface (optional): ASCII RS-232 or RS-485 compatible; format 1 start bit, 8 data bits, 1 stop bit and no parity bits Baud Rates: 9600, 4800, 2400, 1200, 600, 300, 150 and 75 programmable from the front panel
Operating Temperature: -20 to 60°C (-4 to 140°F)
Storage Temperature: -25 to 85°C (-12 to 184°F)
Relative Humidity: 0% to 90%, Non-condensing
Power: 115 Vac (+15% -10%) @ 50 mA (47 to 500 Hz) Optional: 230 Vac (+15% -10%) @ 25 mA (47 to 500 Hz) Optional: 9-18 or 18-36 Vdc
Dimensions: 1.97 H x 3.80 W x 4.0" D (50 x 97 x 102 mm) (Rear Connectors add 0.5" to depth)
Panel Cutout: 1 /8 DIN 45 H x 92 mm W (1.77 H x 3.58" W)
Weight: 454 g (1 lb)
Examples of pricing for popular models is referenced in the "To Order" box. Use the "Part Number Builder" below to get pricing for all available models.
PDF et manuels
Afficher les notes et les avis