- Dielectric Strength in Excess of 2000V
- Enclosure Ratings IP5X
- Exposure Temperature, Max 760 °C
- Heater Width 0 in
- Heating Element Gauge 36 to 40 AWG
- Heating Element Gauge Note 36-40 gauge finely stranded resistance wire
- Insulation Double-Braided Samox
- Lead Temperature, Max 260 °C
- Lead Wire Exit Direction Note Emerge from opposite ends into separate sides of integrally molded separate plug. Maximum temperature for lead wires is 260CELSIUS (500°F).
- Thermostat Type Not Built-In
- Wire Length 24 in
Description
Cliquez sur le lien pour plus d’informations sur les eléments chauffant soupleLes rubans standard sont fabriqués à partir de fils de résistance très fins et toronnés, avec double isolation au Samox tressé et cousus en rubans plats pour une souplesse optimale.
Un ruban à isolation renforcée est obtenu en prenant un ruban standard et en le tressant entre plusieurs couches de brins de Samox. Les rubans larges sont obtenus à partir de deux rubans standard ou plus, cousus entre deux couches de tissu de Samox.
CARACTÉRISTIQUES
Éléments chauffants : fil de résistance toronné de calibre 36-40
Éléments chauffants isolés : Samox en double tresse
Rigidité diélectrique : supérieure à 2 000 V
Fils conducteurs : ils sortent des extrémités opposées de la fiche séparée entièrement moulée en sections distinctes. La température maximale des fils conducteurs est de 260 °C (500 °F).
PDF et manuels
Afficher les notes et les avis
Rated 5 out of
5
by
Testers from
New appliance
Works on dioxane need double element for sulfuric acid
Date published: 2018-11-30
Rated 5 out of
5
by
SEALEC Ecuador from
awesome heat conduction
We bought this product for my cousin in SA. He has a mechanical seals manufacturing business. The only way to make a permanent seal is with heat...we could not find a more effective product with awesome heat conduction for this purpose. It works like magic.
Date published: 2017-02-11
Rated 5 out of
5
by
JesseMER from
1/2" heater tape
Excellent quality, short lead time for a much better product than you can get at McMaster or Amazon
Date published: 2023-09-04
Rated 5 out of
5
by
Tape for fluid from
Heating tape
Very good quiality, the tape works well and we have some of the same brand and are in perfect status
Date published: 2023-02-09
Do these flexible heaters have CSA certificate for application in Canada?
Hi Hossein,
Thank you for the inquiry. These do not include CSA certificate unfortunately.
Best regards
OMEGA
Date published: 2022-01-21
Is 1400F (760C) mean reusable temperature or one-time?
The Heater tape will have to be attached to a Thermally Conductive surface across it's full length. What temperature that can be reached will depend on the Thermal mass and the Wattage of the specific Heater Tape. Once in place it is best to leave it in place as there will be some embrittlement. Running the Heater at full Voltage and power will reduce its expected useful life.
Date published: 2023-03-19
Can Ultra-High Temperature Heating Tape be used to heat a pipe will be buried under ground?
The Ultra-High Heating tape is not recommended for underground or wet environments. Look at self regulating or constant Wattage Heater tapes as a possible alternative.
Date published: 2022-04-07
What is a reliable temperature controller to use with heating tapes (Heating Tape STH051-080 for example? I am currently using an obsolete CN 9111A controller. These controllers worked fine but did not last very long (Mechanical relay and not SSR).
Thank you for your inquiry. The CN9111A suitable replacement would be a CNi1644 coupled with a SSRL240DC10 solid state relay.
Date published: 2023-05-04
Is this product UL US listed?
Thank you for your inquiry. This product is not UL listed.
Date published: 2024-04-05
Is the supply voltage for this heater AC or DC?
Thank you for your inquiry. This heater requires 120 Vac.
Date published: 2024-02-12
Hello! what is the difference between 120 or 240 volts? the size of the wire or its just the 240 volts does not come with a connector (model SST051-040) THANK YOU FOR YOUR TIME
Thank you for your inquiry. The difference is that 240V Version does not come with a plug.
Date published: 2022-10-11
Is the fiberglass insulation enough to prevent electrical shorting on conductive surfaces?
The Fiberglass insulation on the STH and SWH models provides the electrical insulation needed to be able to be use them on conductive surfaces.
Date published: 2021-11-16