1-800-663-4209 | Vos commentaires sont importants, répondez à un sondage rapide commentaires sur le site web

DPF-521-522-Series
Flow Batching Processor with Output Controls
- Batch Control
- Regeneration Control
- High/Low Flow Rate Monitoring
- Water Usage Monitoring
DPF-521-522-Series
Depuis
C$
2,065.02

L'aperçu du produit
- Approvals RoHS Compliance
- Control Output 2 SPDT Relay, 2 Isolated DC Pulse
- Cutout Dimensions 5.67 x 5.67 in
- Display Color Black
- Display Note Totalizer = 8 digit Rate = 5 digit, backlit
- Display Type LCD
- Electrical Output 4 to 20 mA, 0 to 5 Vdc
- Enclosure Material Aluminum
- Enclosure Ratings IP56, NEMA Type 4X
- Form factor 1/2 DIN
- Frequency Input Range 1 to 1000 Hz
- Frequency Input Range Note 1 to 1000 Hz, ESD protected, interfaces to current sinking sensor (NPN, TTL, contact closure) output
- Front Panel Dimensions 6.42 x 6.42 in
- Input Type Frequency
- Memory Non-Volatile EEPROM, Auto-backup
- Mounting Orientation Panel Mount, Wall Mount
- Number of Digits 8
- Number of Inputs 1
- Number of Relays 2
- Operating Temperature, Max 55 °C
- Operating Temperature, Min 0 °C
- Panel Depth 4.65 in
- Pulse Output Note 100 mA at 60 Vac/Vdc, opto-isolated, open-collector
- Sensor/Transmitter Power 12 Vdc, 10 mA
- Switch Rating 6A @ 115 Vac
- Switch Type SPDT NO/NC, Selectable
- Switch Type Note Two form C (SPDT) relays, 115 Vac 6A maximum
The DPF-520 Series is a batching flow processor with additional output controls. It is designed for use with OMEGA® flowmeters and flow sensors, as well as other manufactuers products which have frequency output proportional to flow. In addition to batch functions, the DPF-520 Series indicates flow rate, and other data in large 9.66 mm (3/8") digits on an easily-read, backlit display. Units of measure are user selectable. An analog output of 4 to 20 mA is available both in active and passive loop configuration, and in 0 to 5 Vdc or 0 to 10 Vdc outputs, and can be used in applications such as flow rate logging. Two programmable pulse scaled outputs are also standard, and can be used, for example, to provide proportional chemical feed with a pulse-responsive metering pump. The housing is supplied with two brackets for wallmount applications, or the top/bottom housings can be easily separated and reassembled for panel-mount.
SPECIFICATIONS
Power: 115 Vac, 50/60 Hz @ 125 mA, 12 Vdc @ 750 mA or 10 to 16 Vdc (220 Vac optional)
Temperature: 0 to 55 °C (32 to 130 °F)
Enclosure: Precision cast aluminum, NEMA 4X (IP56), panel or wall mount configuration
Batch Outputs: Two form C (SPDT) relays, 115 Vac 6A maximum
Maximum Pulse Output: 100 mA at 60 Vac/Vdc, opto-isolated, open-collector
Memory Type: Non-volatile EEPROM with auto-backup
Sensor Power: 12 Vdc, 10 mA
Display: Totalizer = 8 digit Rate = 5 digit, backlit
Units: Volume = Gallons, cubic feet, cubic meters, millions of gallons, milliliters, fluid ounces, pounds, liters Time = Seconds, minutes, hours, days
Analog Output: 4 to 20 mA passive opto-isolated 4 to 20 mA active 0 to 5 Vdc, or 0 to 10 Vdc
Sensor Input: 1 to 1000 Hz, ESD protected, interfaces to current sinking sensor (NPN, TTL, contact closure) output
Setup Memory: Non-volatile EEPROM, auto-backup
SPECIFICATIONS
Power: 115 Vac, 50/60 Hz @ 125 mA, 12 Vdc @ 750 mA or 10 to 16 Vdc (220 Vac optional)
Temperature: 0 to 55 °C (32 to 130 °F)
Enclosure: Precision cast aluminum, NEMA 4X (IP56), panel or wall mount configuration
Batch Outputs: Two form C (SPDT) relays, 115 Vac 6A maximum
Maximum Pulse Output: 100 mA at 60 Vac/Vdc, opto-isolated, open-collector
Memory Type: Non-volatile EEPROM with auto-backup
Sensor Power: 12 Vdc, 10 mA
Display: Totalizer = 8 digit Rate = 5 digit, backlit
Units: Volume = Gallons, cubic feet, cubic meters, millions of gallons, milliliters, fluid ounces, pounds, liters Time = Seconds, minutes, hours, days
Analog Output: 4 to 20 mA passive opto-isolated 4 to 20 mA active 0 to 5 Vdc, or 0 to 10 Vdc
Sensor Input: 1 to 1000 Hz, ESD protected, interfaces to current sinking sensor (NPN, TTL, contact closure) output
Setup Memory: Non-volatile EEPROM, auto-backup
PDF et manuels