<< Voir toutes les modèles de produitsBrand |
![]() |
Accuracy | ± 3 % |
Cable Length | 3 ft |
Display Type | None |
Electrical Connection | Four-Pin |
Electrical Output | 0 to 5 Vdc |
Flow Characteristic | Gas |
Height | 3.5 in |
Length | 3 in |
Linearity | ±3% |
Material Construction Option | Glass-filled Polyphenylene Sulphide |
Materials, Wetted | FKM, PPS, Sapphire, Stainless Steel |
Media Compatibility | Gases |
Mounting | #4 Screw |
Number of Digits | 3.5 |
Operating Pressure Note | 40 psi at 20°C (68°F) |
Operating Pressure, Max | 40 psi |
Operating Temperature, Max | 50 °C |
Operating Temperature, Min | 0 °C |
Output Detail | 0 to 5 Vdc, adjustable ±20% (typical) |
Output Signal | Voltage |
Pressure Drop, Max | 2 inH₂O |
Process Connection Size | 1/8 in |
Process Connection Type | Acetal Tube Fitting |
Repeatability | ±0.5% |
Repeatability Note | ±0.5% FS from 50 to 100% of rated maximum flow for gas |
Storage Temperature, Max | 70 °C |
Storage Temperature, Min | 0 °C |
Supply Current | 30 mA |
Supply Voltage | 11.5 to 15 Vdc |
Temperature Effect | ±0.2%/°C |
Volumetric Flow Rate, Max | 1000 ml/min |
Volumetric Flow Rate, Min | 200 ml/min |
Width | 1.75 in |
Voir toutes Spécs |
PDF et manuels
Afficher les notes et les avis
Rated 4 out of
5
by
Special K from
These work as expected
We have used these in the past, so we know what to expect.
Date published: 2016-06-21
Rated 5 out of
5
by
Manoj Kumar from
Recommend to other other users. Great Product
Recommend to other other users. Great Product with very good quality.
Date published: 2025-02-07
Rated 5 out of
5
by
Muhammad Azeem Ghouri from
Digital Flow Sensor
This flow sensor that I bought works well. The display makes it very convenient to control the flow rate. I highly recommend it.
Date published: 2023-07-26
Rated 5 out of
5
by
mschmid from
Easy and Reliable
We have several of these FLR series flow meters in the lab. They are easy to use, and very reliable.
Date published: 2023-04-01
Rated 5 out of
5
by
mschmid from
Perfect
The flowmeter works perfectly out of the box as advertised.
Date published: 2023-02-05
Rated 1 out of
5
by
Sarath from
VERY POOR! Wrong Reading!
Bought this flowmeter and tested it (measuring cylinder and timer)only to realise the reading was way off the mark.
Please be careful, look for a calibration certification if you plan to get one.
Date published: 2022-02-18
Rated 4 out of
5
by
Pat W from
C+ to B-
FLR1204 20-100L/min works. Spec sheet states "fast response" I did not find this to be true. Power requirements states 30mA (typical) with 11.5 V to 15.0 V supply, so 0.345 W to 0.45 W. Data logger has .4 W. Will data logger power the senor or not??? Also, the FLR1204 sensor is on a by-pass plumbing, I was not aware of this.
Date published: 2021-02-27
Rated 3 out of
5
by
Bhampton from
works and functions but limited
Purchased unit but had to return the first one due to a defect on the screen. got the second one in and it works great, in an environment without any back pressure. The second any pressure is added to the mix the gauge is rendered useless. unfortunately the testing we are performing requires some pressure while still maintaining flow and we are not able to get the value we are looking for. looking at other gauges that might have a different system to make our test work.
Date published: 2019-04-10