Spécifications du produit
<< Voir toutes les modèles de produitsBrand |
![]() |
Accuracy | ± 0.02 % |
Approvals | RoHS, CKCA, CE |
Data Interface | RS232 |
Display | No Display |
Electrical Output | Amplified Square Wave |
Features | Blade Angle : 15° ; Bearing Styles : Self-lubricating, ceramic hybrid ball bearings |
Flow Rate Note | Air 35 to 40 psi @ 0.25lb/ft³,Natural Gas 2 to 3 psi @ 0.05lb/ft³ |
Frequency Input Range | 0.2 to 4000 Hz |
Humidity Range | 0 to 90% RH non-condensing |
Input Control Signal | MCP Pickup |
Linearity | ±1% |
Materials | Aluminum |
Materials, Wetted | 17-4 Stainless Steel, 316L Stainless Steel |
Media Compatibility | Air, Natural Gas |
Operating Pressure, Max | 6000 psi |
Operating Temperature, Max | 85 °C |
Operating Temperature, Min | -40 °C |
Output Detail | Analog Output: 4 to 20 mA, 1 to 5V, 24 mA overflow condition (dip switch selectable);Signal Level:10 mV rms to 30 Vdc;Load Resistance Note:Maximum 650 Ω @ 24 Vdc;Recommended Minimum Load Resistance: 50 KΩ;Pulse Scaling:Divide by 1,10,100 per flow unit of measure |
Output Signal | Current, Voltage, DC Pulse |
Overload, Max | 7.5 ACFM |
Pipe Size, Max | 0.375 in |
Pressure Drop Note | 0.1 psid @ Air, 0.02 psid @ Natural Gas |
Pressure Drop, Max | 0.1 psi |
Process Connection Size | 1/2 in |
Process Connection Type | NPT Male |
Repeatability | ±0.25% |
Repeatability Note | ±0.25% over tabulated repeatable range |
Supply Power Note | 13 to 30 Vdc Standard, 100 to 240 Vac (-AC) (optional), Reverse Polarity Protection |
Supply Voltage | 13 to 30 Vdc |
Temperature Drift | 40 ppm/°C |
Volumetric Flow Rate, Max | 5 ACFM |
Volumetric Flow Rate, Min | 0.6 ACFM |