  • Bridge Resistance 350 Ω
  • Cable Length 20 ft
  • Calibration Option NIST
  • Electrical Connection Cable
  • Hysteresis ± 0.02%
  • Interchangeability 0.0025
  • Load Cell Type Bending Beam
  • Operating Temperature, Max 66 °C
  • Operating Temperature, Min -18 °C
  • Overload, Max 200% FS
  • Process Temperature, Max 66 °C
  • Process Temperature, Min -18 °C
  • Repeatability ± 0.01%
  • Supply Voltage 10 to 15 Vdc
  • Thermal Span Effect 0.0008% rdg/°F
  • Thermal Zero Effect 0.0015% FS/°F
  • Wire Gauge 22 AWG
  • Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
  • Zero/Balance Error ± 1%
SPECIFICATIONS
Rated Output: 3 mV/V ± 0.0075 mV/V (actual output supplied with each load cell)
Excitation: 10 Vdc (15 Vdc maximum)
Accuracy: ± 0.037% Full Scale
Linearity: ± 0.03% FS
Hysteresis: ± 0.02% FS
Repeatability: ± 0.01% FS
Zero Balance: ± 1% FS
Creep In 20 min: ± 0.03% FS
Operating Temperature: 0 to 150°F (-18 to 66°C)
Compensated Temperature: 0 to 150°F (-18 to 66°C)
Thermal effects: Zero - 0.0015% FS/°F Span - 0.0008% RDG/°F
Maximum Load: 200% FS
Side Load Rejection: 500:1
Bridge Resistance: 350 Ohms nominal
Full Scale Deflection: 0.015 in to 0.025 in
Construction: Nickel Plated Steel
Cable: 20 ft 4-conductor shielded 22-gage wire
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

For what applications LCJA-Heavy Duty Shear Beam Load Cells can be used? What is the typical working environment?

Asked by: Nuwa
The LCJA would be used in applications such a tank weighing applications. Their IP67 environmental rating makes them ideal for use in outdoor application or where frequent washdown of equipment is required.
Answered by: Applicatrions Engineer JK
Date published: 2019-11-20

Can I pass a bolt completely through an LCJA load cell at the partially threaded hole?

Asked by: Facets
Thank you for your inquiry, Yes the hole goes all the way through. Please see Datasheet for dimensions
Answered by: rkent
Date published: 2021-12-16

Which side is facing up when mounted? Spec sheet illustration is a little different than the product I received.

Asked by: MikP
Hello, the product itself is symmetrical and should give you a mV output no matter what side is facing up. If you could send us a picture of your load cell to pressure@omega.com we can mark up the mounting side and send it back to you.
Answered by: SAE DVJ
Date published: 2023-03-24
  • y_2025, m_2, d_20, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_CA, sid_LCJA-10K, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration