Spécifications du produit

<< Voir toutes les modèles de produits
Brand
Additional Features 1 One 5.1 cm (2") Rigid Ambient Probe, One 61 cm (24") Bendable SS Probe with 2.5 cm (1") Tip
Battery Size and Type 3.6V Li-ion
Battery life up to 1 yr
Bendable Portion Diameter 0.062 in
Bendable Portion Length 22 in
Calibration Digital calibration through software
Data Interface USB
Data Interface Note OM-CP-IFC400 USB docking station or OM-CP-IFC406 multiplexer interface required; 125,000 baud
Diameter 24.6 mm
Enclosure Ratings IP68
Form factor Handheld
Height 48 mm
Materials, Wetted 316 Stainless Steel, PEEK, Polyurethane
Measurement Type Temperature
Memory 32767
Memory Note 32,767 readings
Number of Measurements 2
Operating Temperature, Max 140 °C
Operating Temperature, Min -40 °C
Probe Diameter 2 in
Probe Length 0.125 in
Probe Tip Diameter 0.125 in
Probe Tip Length 1.7 in
Readings in Trigger Settings Mode 16,383 readings
Real Time Recording May be used with PC to monitor and record data in real time
Relative Humidity Accuracy ± 3% RH
Relative Humidity, Max 1
Relative Humidity, Min 0%
Samples,Max 33000
Sampling Rate 1 Hz (1 update/second)
Sampling Rate Note 1 reading every second to 1 every 24 hours.
Software Compatibility Windows XP SP3/Vista/7 and 8 (32- and 64-bit)
Start Modes Adjustable Delay Start, Immediate Start
Stop Modes Adjustable Delay Stop, Manual Through Software
Supply Power Type Battery
Temperature Accuracy ± 2.5 °C
Temperature Measurement, Max 260 °C
Temperature Measurement, Min -60 °C
Temperature Resolution 0.01 °C
Temperature Sensor Type RTD
Temperature Sensor Type Note Rigid ambient RTD probe with a stainless steel bendable RTD probe
Time Accuracy 1 minute/month @ 25°C (77°F)
Weight 100 g