PX91N0-5KSI
0 to 5,000 psi, Gauge, 4 to 20 mA, 1/2" High Pressure NPSM, Cable, (-50 to 250 °F)

Choisissez une variante
Electrical Connection
Electrical Output
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-9 | C$1,948.14 |
10-24 | C$1,850.73 |
25-49 | C$1,811.77 |
50-99 | C$1,733.84 |
100+ | C$1,694.88 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
Spécifications du produit
<< Voir toutes les modèles de produitsBrand |
![]() |
Accuracy Class | > 0.25% |
Burst Pressure | 150% Full Scale |
Burst Pressure Note | 150% of rated pressure |
Cable Length | 3 m |
Compensated Temperature, Max | 71 °C |
Compensated Temperature, Min | 17 °C |
Electrical Connection | Cable |
Electrical Output | 4 to 20 mA |
Electrical Output Note | 4 to 20 mA ± 10% adj |
Hysteresis | ± 0.10% FSO |
Linearity Error | ± 0.35% |
Materials, Wetted | 17-4 Stainless Steel |
Operating Temperature, Max | 121 °C |
Operating Temperature, Min | -46 °C |
Output Signal | Current |
Pressure Type | Sealed Gauge |
Pressure, Max | 5000 psi |
Pressure, Min | 0 psi |
Process Connection Note | 1/2-14 NPSM (fits 0.315" dia. 59° ferrule) |
Process Connection Size | 1/2 in |
Process Connection Type | High Pressure NPSM |
Proof Pressure | 120% Full Scale |
Proof Pressure Note | 120% of rated pressure |
Repeatability Error | ± 0.1% full scale |
Supply Voltage | 12 to 40 Vdc |
Thermal Effect on Span error, Max | 0.005% rdg/°F |
Thermal Effect on Zero error, Max | 0.005% rdg/°F, 0.005% FSO/°F |
Zero/Balance Error | 4 mA (+10%, -2% adj) |
Voir toutes Spécs |
Afficher les notes et les avis
Rated 1 out of
5
by
Lacking from
I can't find adapters to fit this 1/2 NPSM fitting
Help I can not find a rated pressure fitting that will work for this gauge. Our setup is all HIP fittings but found that there is nothing available that will adapt to this pressure transducer. Where do you find NPSM adapters that are rated to what this transducer is rated to
Date published: 2022-02-07
Rated 1 out of
5
by
Noah C from
Outdated Thread Type
We bought this pressure transducer ( the PX91N0- 60KSV) for high temperature and pressure research and found out when arrived that it didn't screw into our pressure cell. That wouldn't have been a big deal, except for when we were looking for a thread adapter, we found out nobody makes 1/2 - 14 NPS threads, and had to get a custom built thread adapter.
Date published: 2019-09-27