Skip to search Skip to main content Skip to navigation

Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

MX1104

Choisissez une variante

Number of Measurements

C$328.35

Article# MX1104

En stock

Délai de livraison (si pas en stock): 9 semaines

Spécifications du produit

<< Voir toutes les modèles de produits
Brand
Accuracy Note Temperature Sensor Accuracy: ± 0.20°C from 0° to 50°C (± 0.36°F from 32° to 122°F), Current Accuracy: ± 0.001 mA ± 0.2% of reading, Voltage Accuracy: 0 to 24 V: ± 1.0 mV ± 0.3% of reading, 0 to 2.5 V: ± 0.1 mV ± 0.1% of reading, 0 to 5 V: ± 0.2 mV ± 0.3% of reading, 0 to 10 V: ± 0.4 mV ± 0.3% of reading, RH: ± 2.5% from 10% to 90% (typical) to a maximum of ± 3.5% including hysteresis at 25°C (77°F); below 10% and above 90% ± 5% typical
Approvals CE
Battery Size and Type Alkaline AAA
Battery life 1 yr, typical with reading interval of 1 min
Configuration HOBOmobile® app Android, iOS, iPadOS
Current Accuracy ± 0.001 mA
Current Measurement Range 0 to 20.1 mA
Current Resolution Temperature: 0.002°C, Relative Humidity: 0.01%, Voltage: 384 µV, Current: 0.3 µA
Data Interface Bluetooth
Display LCD
Display Note LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Enclosure Ratings IP54
Form Factor Note Use the four magnets on the back of the logger to mount it to a magnetic surface or insert the tie wraps through the mounting loops to attach it to other surfaces
Form factor Magnetic Surface or Insert the tie wraps
Height 1.15 in
Input Type Internal, External
Length 2.13 in
Light Accuracy ± 10%
Light Measurement Range 0 to 167,731 lux
Logger with Cable Type "Current: SD-MA-420 or CABLE-4-20mA Voltage: 0 to 24 V: SD-VOLT-24 or CABLE-ADAP24 0 to 2.5 V: SD-VOLT-2.5 or CABLE-2.5-STEREO 0 to 5 V: SD-VOLT-05 or CABLE-ADAP5 0 to 10 V: SD-VOLT-10 or CABLE-ADAP10"
Logging Modes burst, Fixed interval
Measurement Type Current, Light Intensity, Relative Humidity, Temperature, Voltage
Memory 4 MB
Memory Modes stop when full, Wrap when full
Memory Note Approximately 4 to 15 minutes depending on the mobile device; may take longer the further the device is from the logger
Number of Measurements 4
Operating Temperature, Max 70 °C
Operating Temperature, Min -20 °C
RH Measurement Range 0 to 100% RH
RH Resolution 0.0001
RH Sensor Drift <1% Per Year
Radio Power 1 mW
Relative Humidity Accuracy ± 2.5% RH
Resistance Resolution Temperature: 0.002°C, Relative Humidity: 0.01%, Voltage: 384 µV, Current: 0.3 µA
Resolution Note Temperature Sensor Resolution: 0.002°C at 25°C
Response Time Temperature: 11 Min, RH: 30 sec
Response Time Note Temperature: 11 Minutes in air moving 1 m/s, RH: 30 seconds to 90% in airflow of 1 m/s
Restart Mode Push button
Samples,Max ~1.9M Samples, Interval Selectable 1 sec to 18hrs
Start Modes At set date and time, Button Push, Immediate Start, Next Interval
Stop Modes Button Push, When Memory is Full, At set date and time, At set Duration
Supply Power Type Battery
Temperature Accuracy ± 0.20°C
Temperature Resolution 0.002 °C
Temperature Sensor Drift < 0.1°C Per Year
Time Accuracy ± 1 minute/month at 25°C
Transmission Range 30.5 m
Voltage Accuracy ± 1.0 mV
Voltage Measurement Range 0 to 2.5 V, 0 to 5.0 V. 0 to 10 V, 0 to 24 V
Voltage Resolution 384 µV
Weight 4.34 oz
Width 4.44 in
Voir toutes Spécs Montrer moins
HOBO MX BLE Analog, Temp, RH, & Light Logger MX1104 MX1104
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
fr-CA
fr
Enregistrer la configuration