- Alarm Audible: >98 dB @ 2' ; Relay: 1 form “C”, non-latching; 10 A @ 240 Vac, 8 A @ 24 Vdc, 1 ⁄2 hp @ 240 Vac ; Visual: Flashing “ALARM” message
- Dew/Frost Point Accuracy 0.2°C (± 0.5°F)
- Dew/Frost Point Temperature Max 50 °C
- Display Type LED
- Electrical Output 4 to 20 mA
- Enclosure Aluminium
- Enclosure Ratings IP55, NEMA Type 12
- Measurement Type Dew Point
- Mounting Space-Saving Wall Mount
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Output Detail 4 to 20 mA (0 to 5 Vdc), -50 to 50°C (-58 to 122°F) or -60 to 75°C (-76 to 167°F)
- Process Connection Size 1/4 in
- Process Connection Type Compression Fitting
- Process Temperature, Max 50 °C
- Sample Flow Rate 0.5 to 5.0 scfh, Integral flow meter
- Sample Pressure 0 to 150 psig (higher pressures available, consult Engineering Department)
- Supply Voltage 90 to 250 Vac
- Temperature Accuracy ± 0.2 °C
- Temperature Accuracy Note ± 0.2 °C (± 0.5 °F)
Description
These compressed air dewpointmonitors have been designed tooffer the highest level of reliabilityand accuracy available in suchsystems. They are fully NISTtraceable and employ a chilledmirrorsensor, the most accuratedewpoint sensing scheme available,to deliver consistent drift-freemeasurements without regularcalibrations or sensor replacement.These compressed air monitors arecomplete dewpoint measuringsystems. The ruggedized aluminumNEMA 12 (IP55) enclosure housesthe sensor, control circuitry(including flow control) and is easilywall mounted to conserve space.Only the sample line and powerconnection are needed for thesystem to be operational.
The monitors also offer aprogrammable automatic balancecontrol (ABC) cycle that corrects forthe light-reducing effects of mirrorcontaminates and allows forcontinuous monitoring and virtuallymaintenance-free operation.
Specifications:
DEW/FROST POINT RANGE
Two-Stage (S2): -40 to 50°C (-40 to 122°F)
Three-Stage (S3): -60 to 50°C (-76 to 122°F)
Dew/Frost Point Accuracy: 0.20°C (± 0.5°F)
FUNCTIONALITY
Power: 90 to 250 Vac, 50 to 400 Hz
Operating Temperature: 0 to 50°C (32 to 122°F)
Sample Connection: 1/4" compression fitting
Sample Flow Rate: 0.5 to 5 SCFH integral flowmeter
Sample Pressure: 0 to 150 psig
(higher pressures available, consult Engineering Department)
Output: Analog: 4 to 20 mA (0 to 5 Vdc), 50 to 50°C (-58 to 122°F) or
-75 to 75°C (-103 to 167°F)
Compliance: 9.0 Vdc, 450 .
Display: Red LED, 0.5" tall 8-digit alphanumeric
ALARM:
Audible: >98 dba @ 2'
Relay: 1 Form C, non-latching 10 A @ 240 Vac, 8 A @ 24 Vdc, 1/2 HP @ 240 Vac
Visual: Flashing “ALARM” message