Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

LCCD
IP67 Environmentally Protected S-Beam Load Cells
Modèles en stock
- Environmentally Protected to IP67
- All Stainless Steel for Industrial Environments
- 5 Point Calibration with 59 kOhm Shunt Cal Data
- Tension Calibration Standard
LCCD
Depuis
C$
912.11
Modèles en stock

L'aperçu du produit
- 5-Point Calibration 0%, 50%, 100%, 50%, 0%
- Bridge Resistance 350 Ω
- Cable Length 20 ft
- Calibration Option 5 POINT NIST
- Creep in 20 min 0.0003
- Electrical Connection Cable
- Electrical Output 3 mV/V
- Enclosure Ratings IP67
- Force Type Compression, Tension
- Hysteresis 0.0002
- Interchangeability 0.0025
- Load Cell Type S-beam
- Materials 17-4 PH Stainless Steel
- Operating Temperature, Max 66 °C
- Operating Temperature, Min -18 °C
- Overload, Max 300% FS
- Process Temperature, Max 66 °C
- Process Temperature, Min -18 °C
- Repeatability 0.0001
- Safe Overload 150% FS
- Supply Power Note 10 Vdc, 15 Vdc maximum
- Supply Voltage 10 Vdc
- Thermal Span Effect 0.0015% rdg/°C
- Thermal Zero Effect 0.0027% FS/°C
- Wire Gauge 22 AWG
- Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
- Zero/Balance Error 0.01
The LCCD is also available in metric configurations, with 0-10 to 0-5,000 kgf ranges and metric thread. Please see the LCMCD for complete details, or contact our Pressure department for more information.
SPECIFICATIONS
Excitation: 10 Vdc (15 Vdc maximum)
Output: 3.0 mV/V ± 0.25%
Linearity: 0.03% FS
Hysteresis: 0.02% FS
Repeatability: 0.01% FS
Zero Balance: 1% FS
Creep in 20 min: 0.03% FS
Operating Temperature: -18 to 66°C (0 to 150°F)
Compensated Temperature: -18 to 66°C (0 to 150°F)
Thermal Effects:
Zero: 0.0027% FS/°C
Span: 0.0015% rdg/°C
Maximum Load: Safe, 150%; ultimate, 300%
Bridge Resistance: 350 ? nominal
Construction: 17-4 PH stainless steel
Cable: Cable: 6 m (20') 4-conductor shielded 24-gage wire (20 AWG for 15K & 20K lb. capacities)
Afficher les notes et les avis
Rated 4 out of
5
by
Dan E from
Great Load Cell
Works well in all conditions, what we use it for it is located in the elements and works great all the time.
Date published: 2024-09-30
Rated 5 out of
5
by
Luke S from
Gets the job done!
Excellent product. Easy to install and configure. Gives solid information feedback.
Date published: 2023-07-26
Does this come with Rod Ends?
Dear Sbprin,
No, does not come with RodEnds.
Once you select your range please use the datasheet link and scroll down to see the rod ends:
They will start with REC-XXX
Or you can also email pressure@omega.com
Date published: 2020-06-16
Are CAD models available for this product?
No CAD models of the LCCD are available
Date published: 2021-07-20
Does the LCCD-50 model have threaded holes at the ends, or is there a different model that allows for threaded ends?
Thank you for your inquiry, The LCCD has Threaded holes on both ends, please see data sheet for thread sizes.
Date published: 2021-10-14
What is the end cable type? Is there something that can be purchased that allows for easy connection to a NI DAQ machine?
Thank you for your inquire
The end of the cable is stripped leads. You can purchase converters that change the milli volt signal to a usb,voltage or current.
Please contact the engineering department directly to discuss in detail.
Date published: 2021-10-11