Spécifications du produit
<< Voir toutes les modèles de produitsBrand |
![]() |
AC Adaptor Operating Temperature | 0 to 40 °C |
Accuracy Note | Accuracy/Range at 25°C: Non-Condensing: 10 to 90%: 2.75% RH, 5 to 10% and 90 to 95%: ± 3% , 0 to 5% and 95 to 100%: ± 4% |
Approvals | CE, FCC-B |
Battery Operating Temperature | -18 to 55 °C |
Cable Length | 10 ft |
Cable Temperature, Max | 105 °C |
Cable Temperature, Min | -55 °C |
Configuration | Internal Web UI |
Data Interface | Ethernet |
Data Interface Note | Ethernet (RJ45): 10BASE-T Protocols :TCP, UDP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet |
Electrical Connection | Stripped Leads |
Form factor | DIN rail mount |
Height | 0.99 in |
Hysteresis | ± 1% RH |
Input Type | External |
Length | 3.54 in |
Measurement Type | Barometric Pressure, Dew Point, Relative Humidity, Temperature |
Non-Linearity | ± 3% |
Number of Measurements | 3 |
Operating Temperature, Max | 70 °C |
Operating Temperature, Min | 0 °C |
Pressure Accuracy | ± 3.5 mbar |
Pressure Resolution | 0.1 mbar |
Pressure, Max | 110 kPa |
Pressure, Min | 1 kPa |
Probe Diameter | 0.63 in |
Probe Length | 5 in |
Probe Style | Industrial Probe |
RH Measurement Range | 0 to 100% RH |
RH Resolution | 0.1%, 12 bit |
Relative Humidity Accuracy | ± 2.75% for 10 to 90%; ± 3% for 5 to 10% and 90 to 95%; ± 4% for 0 to 5% and 95 to 100% |
Repeatability | ± 0.1% |
Response Time | Temperature: 5 to 30 sec, RH: 8 sec |
Response Time Note | Temperature: 5 to 30 seconds, tau 63%, RH: 8 seconds, tau 63% |
Sensor Type | Screw Terminal |
Software | OPC Server; macro for data logging in Excel program; compatible with Windows® operating systems |
Storage Temperature, Max | 85 °C |
Storage Temperature, Min | -40 °C |
Supply Power Note | Safety-Qualified AC Power Adaptor, Nominal Output: 9 Vdc @ 0.5 A , Input (iBT(H)X-W, iBTX-SD): 100 to 240 Vac, 50/60 Hz (included), Switching Power Supply (iBT(H)X-D): Sold separately (iDRN-PS-1000), Back-up Battery (iBTX-SD): 9V alkaline (included) |
Supply Power Type | DC |
Supply Voltage | 10 to 32 Vdc |
Temperature Accuracy | ± 0.5 °C |
Temperature Repeatability | ± 0.1 °C |
Temperature Resolution | 0.1 °C |
Weight | 0.25 lb |
Width | 4.53 in |
Voir toutes Spécs |
PDF et manuels
Logiciels et pilotes
Afficher les notes et les avis
Rated 5 out of
5
by
DocS from
Perfect Fit
I purchased this unit to provide environmental data for our wind tunnel.
Date published: 2016-11-18
Rated 5 out of
5
by
FrankDLT from
Killer Application for Engineering/Scientific
These sensors are very good. We have them in all our labs and offices. The output data is utilized with our own custom desktop application. Sensing humidity is also a big plus for us due to the organic sensors we make.
The built-in server makes the sensor a powerful tool such that all in the company can use the data as a reference for the ambient environment.
Now we cannot live without them...thanks much!
Date published: 2021-04-26