FMA-LP1600A-Series
Low Pressure Drop Gas Mass Flow Meters
Modèles en stock
- Ranges of 0 to 0.5 SCCM Up to 0 to 500 SLM
- Reports Mass Flow, Volumetric Flow, Temperature, and Pressure
- < 10 ms Response Time—Field Adjustable
- 130+ Gas Calibrations, Including Air, Ar, CH4, CO, CO2, Ethane, H2, He, N2, N2O, Neon, O2, Propane, Butane, Iso-Butane, Acetylene, Ethylene, Krypton, Xenon, and Sulfur Hexafluoride
FMA-LP1600A-Series
Depuis
C$
2,461.04
Modèles en stock

L'aperçu du produit
- Accuracy ± 0.8 %
- Accuracy Note ± (0.8% of rdg + 0.2% FS)
- Additional Features 1 Power Supply Included
- Calibration NIST 5-Point Certificate
- Data Interface RS232
- Display Type LCD
- Electrical Connection 8-pin mini DIN
- Enclosure Ratings IP40
- Height 4.4 in
- Humidity Range 0 to 100% RH non-condensing
- Length 4 in
- Mass Reference Conditions 25°C, 14.7 psia (STP)
- Materials, Wetted Aluminum, FKM, Nylon, Silicone, Stainless Steel
- Measurable Flow Rate 125%
- Media Compatibility Air, Gases, Nitrogen, Oxygen
- Operating Pressure, Max 50 psi
- Operating Pressure, Min 0 psi
- Operating Temperature, Max 50 °C
- Operating Temperature, Min -10 °C
- Pressure Drop, Max 0.25 psi
- Pressure Drop Note 0.25 Pressure Drop at Max Flow (psid) Venting to Atmosphere
- Repeatability ± 0.2%
- Response Time 10 ms
- Response Time Note 10 ms typical default response time for 63.2% of a step change. A variable register allows response time to be field adjustable via RS232 communications.
- Span Shift 0.02% FS/°C/atm
- Supply Current 40 mA
- Supply Power Note 40 mA typical current draw; 100 mA available supply recommended
- Turndown Ratio 200:1
- Volumetric Flow Rate, Min 0.1 SLM
- Width 1.6 in
The FMA-LP1600A Series mass and volumetric flowmeters use the principle of differential pressure within a laminar flow field to determine the mass flow rate. A laminar flow element (LFE) inside the meter forces the gas into laminar (streamlined) flow. Inside this region, the Poiseuille equation dictates that the volumetric flow rate be linearly related to the pressure drop. A differential pressure sensor is used to measure the pressure drop along a fixed distance of the LFE. This, along with the viscosity of the gas, is used to accurately determine the volumetric flow rate. Separate absolute temperature and pressure sensors are incorporated and correct the volumetric flow rate to a set of standard conditions. This standardized flow rate is commonly called the mass flow rate and is reported in units such as standard cubic feet per minute (SCFM) or standard liters per minute (SLM). Standard units include a 0 to 5 V output (4 to 20 mA optional) and RS232 communications. The gas select feature can be adjusted from the front keypad or via RS232 communications. Volumetric flow, mass flow, absolute pressure, and temperature can all be viewed or recorded through the RS232 connection. It is also possible to multi-drop up to 26 units on the same serial connection to a distance of 38 m (125'). These flowmeters can be portable with an optional battery pack (-B models).
Specifications
Mass Reference Conditions: (STP) 25Û¥C, 14.7 PSIA
Accuracy: ± (0.8% of rdg ± 0.2% FS)
Repeatability: ± 0.2%
Turndown Ratio: 200:1
Response Time: 10 ms typical default response time for 63.2% of a step change. A variable register allows response time to be field adjustable via RS232 communications.
Output: 0 to 5 Vdc standard
Operating Temperature: -10 to 50°C (14 to 122°F)
Zero Shift: 0.02% FS/°C/atm
Span Shift: 0.02% FS/°C/atm
Humidity Range: 0 to 100% non-condensing
Pressure (Maximum): 50 psig
Measurable Flow Rate: 125% FS
Supply Voltage: 7 to 30 Vdc (15 to 30 Vdc for 4 to 20 mA output)
Supply Current: 40 mA typical current draw; 100 mA available supply recommended
Cable Connection: 8-pin mini DIN
Wetted Parts: 302 and 303 SS, FKM, silicone RTV, nylon 616, aluminum
Ingress Protection: IP40
-LSS (Option):316LSS, 303SS, 430FRSS, Perfluoroelastomer standard, FKM, EPDM, Buna, Neoprene
Communications: RS232 standard, RS485 (optional)
PDF et manuels
Afficher les notes et les avis
Rated 5 out of
5
by
Willie from
Air flow rate
Works great and is very stable. I am reading 5 cc/min rate and it is rock solid at 2 decimal places.
Date published: 2024-07-16
Rated 3 out of
5
by
Anonymous from
Procurement Agent
We procured this Flowmeters for our Aerospace industry from our existing supplier - Omega who supports our requirements with timely updates against the orders
Date published: 2024-06-03
Does it come with Calibration Certificate ?
Thank you for your inquiry. Yes, it is included with the purchase, see also the data sheet as well.
Date published: 2024-10-03
What is the minimum pressure that your mass flow meters need in order to measure with the accuracy indicated in the specifications?
Thank you for your inquiry. The pressure drop or required pressure is 0.07 PSI for the 10 sccm unit.
Date published: 2025-01-30
Are any of your MFM rated for hazardous environments Class 1 Div 1
Thank you for your inquiry about the mass flow meter. Unfortunately, Omega's MFM or MFC are not rated for hazardous applications.
Date published: 2022-01-24
Hi, We have ordered some FMA-LP1606A-B sensors. Do the battery-powered units have different sizes comparing to the normal ones? Thank you.
Thank you for your inquiry about the mass flow meter. The dimensions for the portal battery style have slight changes in height and depth in that respect.
Date published: 2022-09-15
Hi, I have ordered FMA-LP1615A. Will it come with an RS232 communications cable? Can the RS232 communications cable directly connect to computer and record real-time data?
Thank you for your inquiry. Unless you have a converter module to connect the lead wires from the cable included to a USB connector. There is a cable, FMA1600-C4, that is sold separetely that will have a USB connector to connect into your PC.
Date published: 2023-12-01