Skip to search Skip to main content Skip to navigation

Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

LC8150

Low Profile Through-Hole Load Cells, 1.5 Inch O.D.

  • 5 Point NIST Traceable Calibration with
  • 59 kOhm Shunt Cal Data
  • Low Profile
  • All Stainless Steel Construction
LC8150
Depuis C$ 1 008.93
Low Profile Through-Hole Load Cells, 1.5 Inch O.D. LC8150 LC8150
loading all models
L'aperçu du produit
  • 5-Point Calibration 0%, 50%, 100%, 50%, 0%
  • Cable Length 5 ft
  • Calibration Option 5 POINT NIST
  • Electrical Connection Cable
  • Electrical Output 2 mV/V
  • Force Type Compression
  • Full Scale Deflection 0.003 in
  • Height 0.5 in
  • Input Resistance 360 Ω min
  • Linearity ± 0.5%
  • Load Cell Type Through Hole
  • Materials 17-4 PH Stainless Steel
  • Operating Temperature, Max 121 °C
  • Operating Temperature, Min -54 °C
  • Outer Diameter 1.5 in
  • Output Resistance 350 ± 5 Ω
  • Overload, Max 300% FS
  • Process Temperature, Max 71 °C
  • Process Temperature, Min 16 °C
  • Repeatability ± 0.1%
  • Safe Overload 150% FS
  • Supply Power Note 10 Vdc, 15 Vdc maximum
  • Supply Voltage 10 Vdc
  • Thermal Span Effect ± 0.018% rdg/°C
  • Thermal Zero Effect ± 0.009% FSO/°C
  • Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
  • Zero/Balance Error ± 2%
The LC8150 Series Donut Load Cell is an economical solution to applications requiring a through-hole design. With its extremely low profile and compact design, this load cell is ideal for applications such as clamping forces, bolt loading forces and other compressive loads. This series, with its all stainless steel construction and environmental protection, has proven its reliability in tough industrial applications.

SPECIFICATIONS
Output: 2 mV/V nominal
Input: 10 Vdc (15V max)
Linearity: ± 0.5% FSO
Repeatability: ± 0.1% FSO
Zero Balance: ± 2.0% FSO
Operating Temp Range: -54 to 121°C (-65 to 250°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ± 0.009% FSO/°C
Span: ± 0.018% rdg/°C
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Deflection: 0.076 mm (0.003") nominal
Input Resistance: 360 ? minimum
Output Resistance: 350 ± 5 ?
Construction: 17-4 PH stainless steel
Electrical: 1.5 m (5') 4-conductor shielded cable
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

What are the dimensions of the upper and lower loading surfaces for these load cells? This dimension is not included in the datasheet.

Asked by: Austin90
The top loading surface is 0.750 inches and the bottom flat surface is 1.500 in ( the extruded dimension is 1.310in )
Answered by: PressureE
Date published: 2020-05-27

What size are the conductors in the cable for the LC8150 series load cells? This is not present on the datasheet

Asked by: TestMonkey
Thank you for your inquire. The wires are approximately 24 to 6 gauge wire
Answered by: application engineer je
Date published: 2022-10-27
  • y_2025, m_2, d_19, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_CA, sid_LC8150-100-100, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 27ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration