Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

LD320A
LVDT Linear Position Sensors with AC Output
Modèles en stock
- Models with 0.25% Linearity
- 2.5 to 200 mm Total Travel Lengths Available
- Rugged Stainless Steel Body
- IP67 Environmental Rating
LD320A
Depuis
C$
488.65
Modèles en stock

L'aperçu du produit
- Cable Length 1 m
- Enclosure Ratings IP67
- Housing Material 304 Stainless Steel
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -25 °C
- Process Connection Size 12 mm
- Process Connection Type Metric
- Repeatability 0.01%
- Resolution 0.1 μm
- Sensitivity 37 mV/V/mm
The LD320A Series of linear displacement transducers is the perfect combination of high accuracy and ruggedness to suit most general purpose applications. Not only do these products have up to 0.25% linearity, but they are also rated IP67 with a 304 stainless steel case that is hermetically sealed.

Range | A mm (in.) | B mm (in.) |
---|---|---|
-10 to 10 mm | 109 (4.29) | 12.5 (0.49) |
-25 to 25 mm | 169 (6.65) | 29.5 (1.16) |
-50 to 50 mm | 209 (8.23) | 55 (2.17) |
-100 to 100 mm | 291.3 (11.5) | 125 (4.92) |
Model | Sensitivity (mV/V/mm) @ 3Vrms, 3kHz | Output (mV) |
---|---|---|
LD320A-2.5 | 37 | 555 |
LD320A-5 | 37 | 1110 |
LD320A-7.5 | 13 | 3900 |
LD320A-15 | 18.5 | 832.5 |
LD320A-25 | 4 | 2400 |
LD320A-50 | 11 | 1650 |
LD320A-75 | 4 | 1800 |
LD320A-100 | 11 | 990 |

Afficher les notes et les avis
Rated 1 out of
5
by
Eddie_ from
Very unclear what you are buying
There is no manual or datasheet provided for this product.
The core has a rod end, but the core is unguided. This mounting configuration doesn't make sense unless the core is intended to rub on the inside of the coil body.
Provided Test report lists the supply voltage as "Source (VDC): 24", and the output is in V .But this is an AC lvdt so the source should be 3 Vrms, 3kHz. Report also only goes from 0mm to 50mm, should be -50mm to 50 mm.
The part length does not match the table on the webpage. -50 to 50 mm length is listed as 8.23", but is actually 11.5" (The length of the -100 to 100 mm) model.
The harness and test report say 0-50mm, but unit should be -50 to 50 mm.
Date published: 2023-12-20
If the range is +/- 50 mm, shouldn't the B dimension be at least 100 mm at full extension?
Yes. The full extended rod dimension should actually be somewhat longer than 100 millimeters. We will look into this error and have the dimensions on the product page corrected.
Date published: 2023-04-17
What is the response rate of this LVDT in milliseconds?
We believe that you are asking about frequency response which is expressed in hertz. Frequency response of the unit is typically 460 Hz.
Date published: 2024-07-19